4 resultados para point-of-care testing
em DRUM (Digital Repository at the University of Maryland)
Resumo:
Deficits in social communication and interaction have been identified as distinguishing impairments for individuals with an autism spectrum disorder (ASD). As a pivotal skill, the successful development of social communication and interaction in individuals with ASD is a lifelong objective. Point-of-view video modeling has the potential to address these deficits. This type of video involves filming the completion of a targeted skill or behavior from a first-person perspective. By presenting only what a person might see from his or her viewpoint, it has been identified to be more effective in limiting irrelevant stimuli by providing a clear frame of reference to facilitate imitation. The current study investigated the use of point-of-view video modeling in teaching social initiations (e.g., greetings). Using a multiple baseline across participants design, five kindergarten participants were taught social initiations using point-of-view video modeling and video priming. Immediately before and after viewing the entire point-of-view video model, the participants were evaluated on their social initiations with a trained, typically developing peer serving as a communication partner. Specifically, the social initiations involved participants’ abilities to shift their attention toward the peer who entered the classroom, maintain attention toward the peer, and engage in an appropriate social initiation (e.g., hi, hello). Both generalization and maintenance were tested. Overall, the data suggest point-of-view video modeling is an effective intervention for increasing social initiations in young students with ASD. However, retraining was necessary for acquisition of skills in the classroom environment. Generalization in novel environments and with a novel communication partner, and generalization to other social initiation skills was limited. Additionally, maintenance of gained social initiation skills only occurred in the intervention room. Despite the limitations of the study and variable results, there are a number of implications moving forward for both practitioners and future researchers examining point-of-view modeling and its potential impact on the social initiation skills of individuals with ASD.
Resumo:
To ensure mission-readiness for military members, support for their families is essential. Military family health and health care satisfaction has been a neglected area of study in this population. Satisfaction can be defined in terms of patient-, provider-, and practice-level factors and is influenced by continuity of care, which is often poor in transient military populations. Using a modified patient satisfaction survey, this study found that both the number of moves and assigned providers were significantly associated with continuity of care in military spouses. Further, continuity of care was a significant predictor of satisfaction with military health care.
Resumo:
Rapid, sensitive and selective detection of chemical hazards and biological pathogens has shown growing importance in the fields of homeland security, public safety and personal health. In the past two decades, efforts have been focusing on performing point-of-care chemical and biological detections using miniaturized biosensors. These sensors convert target molecule binding events into measurable electrical signals for quantifying target molecule concentration. However, the low receptor density and the use of complex surface chemistry in receptors immobilization on transducers are common bottlenecks in the current biosensor development, adding to the cost, complexity and time. This dissertation presents the development of selective macromolecular Tobacco mosaic virus-like particle (TMV VLP) biosensing receptor, and the microsystem integration of VLPs in microfabricated electrochemical biosensors for rapid and performance-enhanced chemical and biological sensing. Two constructs of VLPs carrying different receptor peptides targeting at 2,4,6-trinitrotoluene (TNT) explosive or anti-FLAG antibody are successfully bioengineered. The VLP-based TNT electrochemical sensor utilizes unique diffusion modulation method enabled by biological binding between target TNT and receptor VLP. The method avoids the influence from any interfering species and environmental background signals, making it extremely suitable for directly quantifying the TNT level in a sample. It is also a rapid method that does not need any sensor surface functionalization process. For antibody sensing, the VLPs carrying both antibody binding peptides and cysteine residues are assembled onto the gold electrodes of an impedance microsensor. With two-phase immunoassays, the VLP-based impedance sensor is able to quantify antibody concentrations down to 9.1 ng/mL. A capillary microfluidics and impedance sensor integrated microsystem is developed to further accelerate the process of VLP assembly on sensors and improve the sensitivity. Open channel capillary micropumps and stop-valves facilitate localized and evaporation-assisted VLP assembly on sensor electrodes within 6 minutes. The VLP-functionalized impedance sensor is capable of label-free sensing of antibodies with the detection limit of 8.8 ng/mL within 5 minutes after sensor functionalization, demonstrating great potential of VLP-based sensors for rapid and on-demand chemical and biological sensing.
Resumo:
Microfluidic technologies have great potential to help create automated, cost-effective, portable devices for rapid point of care (POC) diagnostics in diverse patient settings. Unfortunately commercialization is currently constrained by the materials, reagents, and instrumentation required and detection element performance. While most microfluidic studies utilize planar detection elements, this dissertation demonstrates the utility of porous volumetric detection elements to improve detection sensitivity and reduce assay times. Impedemetric immunoassays were performed utilizing silver enhanced gold nanoparticle immunoconjugates (AuIgGs) and porous polymer monolith or silica bead bed detection elements within a thermoplastic microchannel. For a direct assay with 10 µm spaced electrodes the detection limit was 0.13 fM AuIgG with a 3 log dynamic range. The same assay was performed with electrode spacing of 15, 40, and 100 µm with no significant difference between configurations. For a sandwich assay the detection limit was10 ng/mL with a 4 log dynamic range. While most impedemetric assays rely on expensive high resolution electrodes to enhance planar senor performance, this study demonstrates the employment of porous volumetric detection elements to achieve similar performance using lower resolution electrodes and shorter incubation times. Optical immunoassays were performed using porous volumetric capture elements perfused with refractive index matching solutions to limit light scattering and enhance signal. First, fluorescence signal enhancement was demonstrated with a porous polymer monolith within a silica capillary. Next, transmission enhancement of a direct assay was demonstrated by infusing aqueous sucrose solutions through silica bead beds with captured silver enhanced AuIgGs yielding a detection limit of 0.1 ng/mL and a 5 log dynamic range. Finally, ex situ functionalized porous silica monolith segments were integrated into thermoplastic channels for a reflectance based sandwich assay yielding a detection limit of 1 ng/mL and a 5 log dynamic range. The simple techniques for optical signal enhancement and ex situ element integration enable development of sensitive, multiplexed microfluidic sensors. Collectively the demonstrated experiments validate the use of porous volumetric detection elements to enhance impedemetric and optical microfluidic assays. The techniques rely on commercial reagents, materials compatible with manufacturing, and measurement instrumentation adaptable to POC diagnostics.