3 resultados para Signal Detection, Psychological

em DRUM (Digital Repository at the University of Maryland)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent legislation and initiatives set forth high academic expectations for all high school graduates in the area of reading (National Governors Association Center for Best Practices, 2010; Every Student Succeeds Act, 2015). To determine which students need additional support to meet these reading standards, teachers can conduct universal screening using formative assessments. Maze Curriculum-Based Measurement (Maze-CBM) is a commonly used screening and progress monitoring assessment that the National Center on Intensive Intervention (2013) and the Center on Instruction (Torgesen & Miller, 2009) recommend. Despite the recommendation to use Maze-CBM, little research has been conducted on the reliability and validity of Maze-CBM for measuring reading ability for students at the secondary level (Mitchell & Wexler, 2016). In the papers included in this dissertation, I present an initial investigation into the use of Maze-CBM for secondary students. In the first paper, I investigated prior studies of Maze-CBM for students in Grades 6 through 12. Next, in the second paper, I investigated the alternate-form reliability and validity for screening students in Grades 9 and 10 using signal detection theory methods. In the third paper, I examined the effect of genre on Maze-CBM scores with a sample of students in Grades 9 and 10 using multilevel modeling. When writing these three papers, I discovered several important findings related to Maze-CBM. First, there are few studies that have investigated the technical adequacy of Maze-CBM for screening and progress monitoring students in Grades 6 through 12. Additionally, only two studies (McMaster, Wayman, & Cao, 2006; Pierce, McMaster, & Deno, 2010) examined the technical adequacy of Maze-CBM for high school students. A second finding is that the reliability of Maze-CBM is often below acceptable levels for making screening decisions or progress monitoring decisions (.80 and above and .90 and above, respectively; Salvia, Ysseldyke, & Bolt, 2007) for secondary students. A third finding is that Maze-CBM scores show promise of being a valid screening tool for reading ability of secondary students. Finally, I found that the genre of the text used in the Maze-CBM assessment does impact scores on Maze-CBM for students in Grades 9 and 10.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider an LTE network where a secondary user acts as a relay, transmitting data to the primary user using a decode-and-forward mechanism, transparent to the base-station (eNodeB). Clearly, the relay can decode symbols more reliably if the employed precoder matrix indicators (PMIs) are known. However, for closed loop spatial multiplexing (CLSM) transmit mode, this information is not always embedded in the downlink signal, leading to a need for effective methods to determine the PMI. In this thesis, we consider 2x2 MIMO and 4x4 MIMO downlink channels corresponding to CLSM and formulate two techniques to estimate the PMI at the relay using a hypothesis testing framework. We evaluate their performance via simulations for various ITU channel models over a range of SNR and for different channel quality indicators (CQIs). We compare them to the case when the true PMI is known at the relay and show that the performance of the proposed schemes are within 2 dB at 10% block error rate (BLER) in almost all scenarios. Furthermore, the techniques add minimal computational overhead over existent receiver structure. Finally, we also identify scenarios when using the proposed precoder detection algorithms in conjunction with the cooperative decode-and-forward relaying mechanism benefits the PUE and improves the BLER performance for the PUE. Therefore, we conclude from this that the proposed algorithms as well as the cooperative relaying mechanism at the CMR can be gainfully employed in a variety of real-life scenarios in LTE networks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microfluidic technologies have great potential to help create automated, cost-effective, portable devices for rapid point of care (POC) diagnostics in diverse patient settings. Unfortunately commercialization is currently constrained by the materials, reagents, and instrumentation required and detection element performance. While most microfluidic studies utilize planar detection elements, this dissertation demonstrates the utility of porous volumetric detection elements to improve detection sensitivity and reduce assay times. Impedemetric immunoassays were performed utilizing silver enhanced gold nanoparticle immunoconjugates (AuIgGs) and porous polymer monolith or silica bead bed detection elements within a thermoplastic microchannel. For a direct assay with 10 µm spaced electrodes the detection limit was 0.13 fM AuIgG with a 3 log dynamic range. The same assay was performed with electrode spacing of 15, 40, and 100 µm with no significant difference between configurations. For a sandwich assay the detection limit was10 ng/mL with a 4 log dynamic range. While most impedemetric assays rely on expensive high resolution electrodes to enhance planar senor performance, this study demonstrates the employment of porous volumetric detection elements to achieve similar performance using lower resolution electrodes and shorter incubation times. Optical immunoassays were performed using porous volumetric capture elements perfused with refractive index matching solutions to limit light scattering and enhance signal. First, fluorescence signal enhancement was demonstrated with a porous polymer monolith within a silica capillary. Next, transmission enhancement of a direct assay was demonstrated by infusing aqueous sucrose solutions through silica bead beds with captured silver enhanced AuIgGs yielding a detection limit of 0.1 ng/mL and a 5 log dynamic range. Finally, ex situ functionalized porous silica monolith segments were integrated into thermoplastic channels for a reflectance based sandwich assay yielding a detection limit of 1 ng/mL and a 5 log dynamic range. The simple techniques for optical signal enhancement and ex situ element integration enable development of sensitive, multiplexed microfluidic sensors. Collectively the demonstrated experiments validate the use of porous volumetric detection elements to enhance impedemetric and optical microfluidic assays. The techniques rely on commercial reagents, materials compatible with manufacturing, and measurement instrumentation adaptable to POC diagnostics.