7 resultados para Mediterranean Spanish urban system
em DRUM (Digital Repository at the University of Maryland)
Resumo:
Transportation system resilience has been the subject of several recent studies. To assess the resilience of a transportation network, however, it is essential to model its interactions with and reliance on other lifelines. In this work, a bi-level, mixed-integer, stochastic program is presented for quantifying the resilience of a coupled traffic-power network under a host of potential natural or anthropogenic hazard-impact scenarios. A two-layer network representation is employed that includes details of both systems. Interdependencies between the urban traffic and electric power distribution systems are captured through linking variables and logical constraints. The modeling approach was applied on a case study developed on a portion of the signalized traffic-power distribution system in southern Minneapolis. The results of the case study show the importance of explicitly considering interdependencies between critical infrastructures in transportation resilience estimation. The results also provide insights on lifeline performance from an alternative power perspective.
Resumo:
Current methods for large-scale wind collection are unviable in urban areas. In order to investigate the feasibility of generating power from winds in these environments, we sought to optimize placements of small vertical-axis wind turbines in areas of artificially-generated winds. We explored both vehicular transportation and architecture as sources of artificial wind, using a combination of anemometer arrays, global positioning system (GPS), and weather report data. We determined that transportation-generated winds were not significant enough for turbine implementation. In addition, safety and administrative concerns restricted the implementation of said wind turbines along roadways for transportation-generated wind collection. Wind measurements from our architecture collection were applied in models that can help predict other similar areas with artificial wind, as well as the optimal placement of a wind turbine in those areas.
Resumo:
Abstract The purpose of this study was to examine how four high schools used an Early Warning Indicator Report (EWIR) to improve ninth grade promotion rates. Ninth grade on-time promotion is an early predictor of a student’s likelihood to graduate (Bornsheuer, Polonyi, Andrews, Fore, & Onwuegbuzie, 2011; Leckrone & Griffith, 2006; Roderick, Kelley-Kemple, Johnson, & Beechum, 2014; Zvoch, 2006). The analysis revealed both similarities and differences in the ways that the four schools used the EWIR. The research took place in a large urban school district in the Mid-Atlantic. Sixteen participants from four high schools and the district’s central office voluntarily participated in face-to-face interviews. The researcher utilized a qualitative case study method to examine the implementation of the EWIR system in Wyatt School District. The interview data was transcribed and analyzed, along with district documents, to identify categories in this cross case analysis. Three primary themes emerged from the data: (1) targeted school structures for EWIR implementation, (2) the EWIR identified necessary supports for students, and (3) the central office support for school staff. The findings revealed the various ways that the target schools implemented the EWIR in their buildings and the level of support that they received from the central office that aided them in using the EWIR to improve ninth grade promotion rates. Based on the findings of this study, the researcher provided a number of key recommendations: (1) Districts should provide professional development to schools to ensure that schools have the support they need to implement the EWIR successfully; (2) There should be increased accountability from the central office for schools using the EWIR to identify impactful interventions for ninth graders; and (3) The district needs to assign dedicated central office staff to support the implementation of the EWIR in high schools across the district. As schools continue to face the challenge of improving ninth grade promotion rates, effective use of an Early Warning Indicator Report is recommended to provide school and district staff with data needed to impact overall student performance.
Resumo:
Common building energy modeling approaches do not account for the influence of surrounding neighborhood on the energy consumption patterns. This thesis develops a framework to quantify the neighborhood impact on a building energy consumption based on the local wind flow. The airflow in the neighborhood is predicted using Computational Fluid Dynamics (CFD) in eight principal wind directions. The developed framework in this study benefits from wind multipliers to adjust the wind velocity encountering the target building. The input weather data transfers the adjusted wind velocities to the building energy model. In a case study, the CFD method is validated by comparing with on-site temperature measurements, and the building energy model is calibrated using utilities data. A comparison between using the adjusted and original weather data shows that the building energy consumption and air system heat gain decreased by 5% and 37%, respectively, while the cooling gain increased by 4% annually.
Resumo:
This research-design thesis explores the implementation of Regenerative Stormwater Conveyance (RSC) as a retrofit of an existing impervious drainage system in a small catchment in the degraded Jones Falls watershed in Baltimore City. An introduction to RSC is provided, placing its development within a theoretical context of novel ecosystems, biomimicry and Nassauer and Opdam’s (2008) model of landscape innovation. The case site is in Baltimore’s Hampden neighborhood on City-owned land adjacent to rowhomes, open space and an access point to a popular wooded trail along a local stream. The design proposal employs RSC to retrofit an ill-performing stormwater system, simultaneously providing a range of ecological, social and economic services; water quantity, water quality and economic performance of the proposed RSC are quantified. While the proposed design is site-specific the model is adaptable for retrofitting other small-scale impervious drainage systems, providing a strategic tool in addressing Baltimore City’s stormwater challenges.
Resumo:
This thesis addresses contemporary gaps of vacancy within literature by using qualitative and quantitative methods and tools to determine the quantity, location, and interspatial relationships of vacant buildings and lots located in Baltimore Maryland. Spatial analyses were conducted to answer three questions of vacancy: 1) how many vacant lots and buildings exist, 2) whether there are spatial patterns of vacancy, such as clustering around geographic locations or within watersheds, and 3) how to prioritize intervention opportunities that respond to the city's larger issues? Using the city’s vacant lot and building data-sets, two concepts emerged from these investigations. First, Utilized Landscapes as a classification system that identifies lands that serve a function but have un-traditional qualities that make them susceptible to being labeled “vacant.” Second, the development of Transitional Zones, geographical areas with a high density of vacant buildings or lots that should be prioritized.
Resumo:
Electric vehicle (EV) batteries tend to have accelerated degradation due to high peak power and harsh charging/discharging cycles during acceleration and deceleration periods, particularly in urban driving conditions. An oversized energy storage system (ESS) can meet the high power demands; however, it suffers from increased size, volume and cost. In order to reduce the overall ESS size and extend battery cycle life, a battery-ultracapacitor (UC) hybrid energy storage system (HESS) has been considered as an alternative solution. In this work, we investigate the optimized configuration, design, and energy management of a battery-UC HESS. One of the major challenges in a HESS is to design an energy management controller for real-time implementation that can yield good power split performance. We present the methodologies and solutions to this problem in a battery-UC HESS with a DC-DC converter interfacing with the UC and the battery. In particular, a multi-objective optimization problem is formulated to optimize the power split in order to prolong the battery lifetime and to reduce the HESS power losses. This optimization problem is numerically solved for standard drive cycle datasets using Dynamic Programming (DP). Trained using the DP optimal results, an effective real-time implementation of the optimal power split is realized based on Neural Network (NN). This proposed online energy management controller is applied to a midsize EV model with a 360V/34kWh battery pack and a 270V/203Wh UC pack. The proposed online energy management controller effectively splits the load demand with high power efficiency and also effectively reduces the battery peak current. More importantly, a 38V-385Wh battery and a 16V-2.06Wh UC HESS hardware prototype and a real-time experiment platform has been developed. The real-time experiment results have successfully validated the real-time implementation feasibility and effectiveness of the real-time controller design for the battery-UC HESS. A battery State-of-Health (SoH) estimation model is developed as a performance metric to evaluate the battery cycle life extension effect. It is estimated that the proposed online energy management controller can extend the battery cycle life by over 60%.