4 resultados para Fire protection districts

em DRUM (Digital Repository at the University of Maryland)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A systematic study was conducted to elucidate the effects of acoustic perturbations on laminar diffusion line-flames and the conditions required to cause acoustically-driven extinction. Flames were produced from the fuels n-pentane, n-hexane, n-heptane, n-octane, and JP-8, using fuel-laden wicks. The wicks were housed inside of a burner whose geometry produced flames that approximated a two dimensional flame sheet. The acoustics utilized ranged in frequency between 30-50 Hz and acoustic pressures between 5-50 Pa. The unperturbed mass loss rate and flame height of the alkanes were studied, and they were found to scale in a linear manner consistent with Burke-Schumann. The mass loss rate of hexane-fueled flames experiencing acoustic perturbations was then studied. It was found that the strongest influence on the mass loss rate was the magnitude of oscillatory air movement experienced by the flame. Finally, acoustic perturbations were imposed on flames using all fuels to determine acoustic extinction criterion. Using the data collected, a model was developed which characterized the acoustic conditions required to cause flame extinction. The model was based on the ratio of an acoustic Nusselt Number to the Spalding B Number of the fuel, and it was found that at the minimum speaker power required to cause extinction this ratio was a constant. Furthermore, it was found that at conditions where the ratio was below this constant, a flame could still exist; at conditions where the ratio was greater than or equal to this constant, flame extinction always occurred.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The goal of this study is to provide a framework for future researchers to understand and use the FARSITE wildfire-forecasting model with data assimilation. Current wildfire models lack the ability to provide accurate prediction of fire front position faster than real-time. When FARSITE is coupled with a recursive ensemble filter, the data assimilation forecast method improves. The scope includes an explanation of the standalone FARSITE application, technical details on FARSITE integration with a parallel program coupler called OpenPALM, and a model demonstration of the FARSITE-Ensemble Kalman Filter software using the FireFlux I experiment by Craig Clements. The results show that the fire front forecast is improved with the proposed data-driven methodology than with the standalone FARSITE model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ASHRAE 34, based on ASTM E681, was improved by identifying and rectifying deficiencies in ASTM E681. An ASTM E681 apparatus and procedure was developed with gaseous refrigerant testing in mind. The plumbing was improved by ensuring that the pressure readings could be constantly monitored while decreasing leakage potential. An original electrical system was designed and constructed for the ignition system. Additionally, a control panel was constructed to isolate hazardous electrical elements, and facilitate the testing, while simultaneously organizing the critical plumbing and ignition components. 3D printing efficiently produced heat-resistant, nonreactive, and structurally stable lower electrode spacers, propellers, and propeller bars. The heating system was designed to ensure even temperature throughout the apparatus. The humidity system was designed to accurately condition the air. Recommendations to improve ASTM E681 are provided. The research can be built on to improve the accuracy and reproducibility of ASTM E681.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The literature on the determination of flammability limits was reviewed and experts on the ASTM E681 standard were interviewed to identify new means of improving the reproducibility of the ASTM E681 test. Venting was identified as a variable of flammability limits not yet addressed. Limitations of the current system for sealing and venting (a rubber stopper) were identified and addressed by the development of a custom burst disc. The burst disc was evaluated for its ability to hold and maintain a vacuum, its ability to vent at pressures of interest, and for its venting phenomena. The burst disc was deemed to be a satisfactory alternative to the rubber stopper and is recommended to be included in the ASTM E681 standard.