The desire of Nebraska people to continue the improvement of living conditions and to secure more healthful foods has been responsible for many changes in methods of caring for milk. One of the important factors in keeping milk sweet and of good quality is the process of cooling and keeping it cool until used. Three of these processes are as follows: placing containers of warm milk in any quantity of still water or still air at temperatures ranging from freezing to within a few degrees of the temperature of the milk, placing the containers in such positions that air or water are circulated around them, and causing the milk to flow in such manner that a thin film comes in contact with a surface which is cooled by air or liquids varying in temperature from 10 degrees Fahrenheit to a few degrees below that of the milk. After some of the heat has been removed the milk is stored under conditions very similar to those found in cooling processes. This 1932 research bulletin discusses why milk is cooled, why milk sours, how bacteria grows, and the many ways that milk can be cooled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the United States the peak electrical use occurs during the summer. In addition, the building sector consumes a major portion of the annual electrical energy consumption. One of the main energy consuming components in the building sector is the Heating, Ventilation, and Air-Conditioning (HVAC) systems. This research studies the feasibility of implementing a solar driven underground cooling system that could contribute to reducing building cooling loads. The developed system consists of an Earth-to-Air Heat Exchanger (EAHE) coupled with a solar chimney that provides a natural cool draft to the test facility building at the Solar Energy Research Test Facility in Omaha, Nebraska. Two sets of tests have been conducted: a natural passively driven airflow test and a forced fan assisted airflow test. The resulting data of the tests has been analyzed to study the thermal performance of the implemented system. Results show that: The underground soil proved to be a good heat sink at a depth of 9.5ft, where its temperature fluctuates yearly in the range of (46.5°F-58.2°F). Furthermore, the coupled system during the natural airflow modes can provide good thermal comfort conditions that comply with ASHRAE standard 55-2004. It provided 0.63 tons of cooling, which almost covered the building design cooling load (0.8 tons, extreme condition). On the other hand, although the coupled system during the forced airflow mode could not comply with ASHRAE standard 55-2004, it provided 1.27 tons of cooling which is even more than the building load requirements. Moreover, the underground soil experienced thermal saturation during the forced airflow mode due to the oversized fan, which extracted much more airflow than the EAHE ability for heat dissipation and the underground soil for heat absorption. In conclusion, the coupled system proved to be a feasible cooling system, which could be further improved with a few design recommendations.