7 resultados para Mobile application testing
em DigitalCommons@University of Nebraska - Lincoln
Resumo:
Butterfat is usually the most expensive ingredient of ice cream; hence, great care is necessary in controllng its use. The manufacturer of ice cream, whether doing a large or a small volume of business, must manufacture a product that will comply with the established fat standard. Some means of determining the percentage of butterfat in the product must be available in order to establish this control. This 1930 research bulletin discusses the different testing equipment used to test butterfat in ice cream.
Resumo:
The comparative cervical skin test for antemortem diagnosis of tuberculosis was done 169 times on 116 different white-tailed deer of known Mycobacterium bovis infection status. The sensitivity and specificity were 97 and 81%, respectively. The magnitude of change in skin thickness at test sites was not significantly influenced by dosage of inoculum, dissemination of the disease process, or repeated skin testing. However, the magnitude of change in skin thickness was significantly greater in deer infected for less than 109 days than in deer infected for more than 109 days. As used in the present study, the comparative cervical skin test is a sensitive method of antemortem diagnosis of M. bovis infection in white-tailed deer.
Resumo:
Where the creation, understanding, and assessment of software testing and regression testing techniques are concerned, controlled experimentation is an indispensable research methodology. Obtaining the infrastructure necessary to support such experimentation, however, is difficult and expensive. As a result, progress in experimentation with testing techniques has been slow, and empirical data on the costs and effectiveness of techniques remains relatively scarce. To help address this problem, we have been designing and constructing infrastructure to support controlled experimentation with testing and regression testing techniques. This paper reports on the challenges faced by researchers experimenting with testing techniques, including those that inform the design of our infrastructure. The paper then describes the infrastructure that we are creating in response to these challenges, and that we are now making available to other researchers, and discusses the impact that this infrastructure has and can be expected to have.
Resumo:
Spreadsheets are widely used but often contain faults. Thus, in prior work we presented a data-flow testing methodology for use with spreadsheets, which studies have shown can be used cost-effectively by end-user programmers. To date, however, the methodology has been investigated across a limited set of spreadsheet language features. Commercial spreadsheet environments are multiparadigm languages, utilizing features not accommodated by our prior approaches. In addition, most spreadsheets contain large numbers of replicated formulas that severely limit the efficiency of data-flow testing approaches. We show how to handle these two issues with a new data-flow adequacy criterion and automated detection of areas of replicated formulas, and report results of a controlled experiment investigating the feasibility of our approach.
Resumo:
A new steel girder bridge system was developed at the University of Nebraska. The innovative girder design is a box girder folded from a single steel plate that has a trapezoid shape with an opening on the bottom. The girder has application in short span bridges and accelerated construction situations. The structural performance of the girder requires investigation in all stages of a bridge’s lifecycle. This thesis contains descriptions and results from the first two tests from a series of tests developed to evaluate this new girder shape. The objective of these two tests was to investigate the constructability of the girders. During construction a bridge is in its least stable condition and it is important that the bridge components exhibit both adequate strength and stability during this critical stage. To this end, two girders were tested in flexure over a simple span as a non-composite beam simulating the loading the girders would be subjected to during construction. The results of the two tests indicate that the folded girder as a whole, and its components, provide adequate strength and stability at construction load levels. Failure occurred at loads that were above normal construction load levels and resulted in a ductile failure mode, which is a well documented benefit of steel components. The girders remained stable through all phases of loading including failure. The top flange was the weakest component of the beam during construction due to its role as a compression element that has a slender and un-braced form. The compression in the top flange caused local buckling in the top flange even at elastic load levels. This was the cause for loss of stiffness and failure in both specimens. Incorporation of a ridge at the center of the top flange of specimens, results of which are not reported in this thesis, proved to resolve this very early buckling issue.
Resumo:
Nearly all biologic tissues exhibit viscoelastic behavior. This behavior is characterized by hysteresis in the response of the material to load or strain. This information can be utilized in extrapolation of life expectancy of vascular implant materials including native tissues and synthetic materials. This behavior is exhibited in many engineering materials as well such as the polymers PTFE, polyamide, polyethylene, etc. While procedures have been developed for evaluating the engineering polymers the techniques for biologic tissues are not as mature. There are multiple reasons for this. A major one is a cultural divide between the medical and engineering communities. Biomedical engineers are beginning to fill that void. A digitally controlled drivetrain designed to evaluate both elastic and viscoelastic characteristics of biologic tissues has been developed. The initial impetus for the development of this device was to evaluate the potential for human umbilical tissue to serve as a vascular graft material. The consequence is that the load frame is configured for membrane type specimens with rectangular dimensions of no more than 25mm per side. The designed load capacity of the drivetrain is to impose an axial load of 40N on the specimen. This drivetrain is capable of assessing the viscoelastic response of the specimens by four different test modes: stress relaxation, creep, harmonic induced oscillations, and controlled strain rate tests. The fluorocarbon PTFE has mechanical properties commensurate with vascular tissue. In fact, it has been used for vascular grafts in patients who have been victims of various traumas. Hardware and software validation of the device was accomplished by testing PTFE and comparing the results to properties that have been published by both researchers and manufacturers.
Resumo:
Petroleum products leaking from under ground storage tanks have raised concerns regarding the quality of ground water resources, The concerns about the environmental behavior and rate of MTBE as an oxygenated additive prompted this iuvestigation to explore the technical characteristics of MTBE in comparison to ETBF. Evaluation of the existing literature suggests that ETBE has more favorable characteristics than MTBE. Findings in this research suggest that ETBE is a technically sound oxygenated octane enhancer, which can help refiners meet specificatios for cleaner burning gasoline.