4 resultados para Global Warming, Building Simulation, Internal Load Density, Adaptation Strategies

em DigitalCommons@University of Nebraska - Lincoln


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is compelling evidence that Planet Earth is on the path to an era of global warming that has serious implications for the well-being of both people and nature. This three-volume synthesis of literature will be a marvelous place for both the public and new scholars interested in global warming to begin their pursuit of the subject. The author captures the best of the scientific literature and press materials appearing in recent years. The utility of these volumes as a resource for gaining a broad background or pursuing a particular aspect of global warming is enhanced by Johansen's talent for explaining with clarity a vast and rapidly growing subject.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ruminal methanogens reduce carbon dioxide to methane (CH 4 ), thereby preventing hydrogen use by bacteria for VFA synthesis resulting in a 2 to 12% loss in feed gross energy. Methane is a greenhouse gas that contributes to global warming. The objectives of this work were to determine: (1) the extent to which ruminal cultures acquire resistance to a nitrofuranyl derivative of para-aminobenzoate (NFP) and an extract from the plant Yucca shidigera (Yucca); (2) the effect of distillers dried grains plus solubles (DDGS) on ruminal CH4 production; (3) the effect of brome hay-based diets, corn-based diets, and in vivo 2-bromoethansulfonate treatment on ruminal methane (CH4 ) production; and (4) the effect of the above treatments on the methanogen population. Ruminal cultures treated with NFP for 90 d maintained a diminished capacity to generate CH4 , but cultures became resistant to the inhibitory effects of Yucca treatment within 10 d. Both treatments decreased (P < 0.01) the relative abundance of total Archaea and the order Methanomicrobiales, but Yucca treatment increased (P < 0.01) the relative abundance of the order Methanobacteriales. The replacement of brome hay and corn with DDGS in lamb diets decreased (P < 0.01) and increased (P < 0.05), respectively, the amount of CH4 produced per unit of digested DM. The substitution of DDGS for brome hay increased (P < 0.01) the relative abundance of the order Methanomicrobiales. The replacement of brome hay with corn decreased (P < 0.05) the amount of CH4 produced per unit of digested DM, and also decreased (P < 0.05) the relative abundance of both Archaea and the order Methanomicrobiales. However, the abundance of the order Methanobacteriales increased (P < 0.05) as corn replaced brome hay. Intraruminal administration of 2-bromoethansulfonate decreased (P < 0.05) CH4 emissions, and decreased (P < 0.05) the relative abundance of Archaea and Methanobacteriales. In conclusion, NFP may be efficacious for chronically inhibiting ruminal methanogenesis, and the replacement of dietary forage with DDGS attenuates CH4 emissions from ruminant animals. Changes in domain- and order-specific ribosomal DNA indicators of methanogens are not consistently correlated with changes in CH4 production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the United States the peak electrical use occurs during the summer. In addition, the building sector consumes a major portion of the annual electrical energy consumption. One of the main energy consuming components in the building sector is the Heating, Ventilation, and Air-Conditioning (HVAC) systems. This research studies the feasibility of implementing a solar driven underground cooling system that could contribute to reducing building cooling loads. The developed system consists of an Earth-to-Air Heat Exchanger (EAHE) coupled with a solar chimney that provides a natural cool draft to the test facility building at the Solar Energy Research Test Facility in Omaha, Nebraska. Two sets of tests have been conducted: a natural passively driven airflow test and a forced fan assisted airflow test. The resulting data of the tests has been analyzed to study the thermal performance of the implemented system. Results show that: The underground soil proved to be a good heat sink at a depth of 9.5ft, where its temperature fluctuates yearly in the range of (46.5°F-58.2°F). Furthermore, the coupled system during the natural airflow modes can provide good thermal comfort conditions that comply with ASHRAE standard 55-2004. It provided 0.63 tons of cooling, which almost covered the building design cooling load (0.8 tons, extreme condition). On the other hand, although the coupled system during the forced airflow mode could not comply with ASHRAE standard 55-2004, it provided 1.27 tons of cooling which is even more than the building load requirements. Moreover, the underground soil experienced thermal saturation during the forced airflow mode due to the oversized fan, which extracted much more airflow than the EAHE ability for heat dissipation and the underground soil for heat absorption. In conclusion, the coupled system proved to be a feasible cooling system, which could be further improved with a few design recommendations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Waxman-Markey Bill is a comprehensive national climate and energy legislation designed to reduce global warming pollution and transition to a clean energy economy. In order to accomplish the first goal, the bill introduces a cap-and-trade program.