3 resultados para Folded-cascode

em DigitalCommons@University of Nebraska - Lincoln


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The folded plate girder, a newly proposed bridge girder, is investigated through this thesis. The folded plate girder is cold bent out of a single sheet of steel. The cold bending eliminates the costly and inconsistent shop welds found in traditional girders. The folded plate girder is meant for application in short span bridges. The girder was subjected to an equivalent 75 year lifetime loading to investigate the fatigue performance. The rebar detail used in the closure region between adjacent slabs has been investigated in the past by the NCHRP 12-68 project. This thesis will proposes a hooked rebar detail as a cost effective alternative to the previously recommended headed rebar detail. The proposed hooked rebar detail looks to improve upon the headed bar detail by increasing the clear cover, and reducing the cost of fabrication and shipment of the rebar. Six specimens containing closure regions are subjected to both positive and negative moment loading in order to investigate their behavior and failure modes under ultimate load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new steel girder bridge system was developed at the University of Nebraska. The innovative girder design is a box girder folded from a single steel plate that has a trapezoid shape with an opening on the bottom. The girder has application in short span bridges and accelerated construction situations. The structural performance of the girder requires investigation in all stages of a bridge’s lifecycle. This thesis contains descriptions and results from the first two tests from a series of tests developed to evaluate this new girder shape. The objective of these two tests was to investigate the constructability of the girders. During construction a bridge is in its least stable condition and it is important that the bridge components exhibit both adequate strength and stability during this critical stage. To this end, two girders were tested in flexure over a simple span as a non-composite beam simulating the loading the girders would be subjected to during construction. The results of the two tests indicate that the folded girder as a whole, and its components, provide adequate strength and stability at construction load levels. Failure occurred at loads that were above normal construction load levels and resulted in a ductile failure mode, which is a well documented benefit of steel components. The girders remained stable through all phases of loading including failure. The top flange was the weakest component of the beam during construction due to its role as a compression element that has a slender and un-braced form. The compression in the top flange caused local buckling in the top flange even at elastic load levels. This was the cause for loss of stiffness and failure in both specimens. Incorporation of a ridge at the center of the top flange of specimens, results of which are not reported in this thesis, proved to resolve this very early buckling issue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the last decade, leaf tatters has been reported in white oak and hackberry across several Midwestern states. Herbicide spray drift studies have shown that chloroacetamides can induce leaf tatters. The objectives of this research were to: 1) identify vulnerable bud developmental stages in hackberry and 2) determine if different commercial chloroacetamides affect severity of leaf tatters. In 2008, a preliminary spray drift experiment was conducted on mature trees from a former hackberry provenance test stand. Acetochlor (Harness), S-metolachlor (Dual II Magnum), and dimethenamid (Outlook) were applied at concentrations approximating 27%, 54%, 81%, or 108% of the recommended field rate. Three developmental stages before bud burst were present on the selected trees. Leaf tatters did not develop on the selected hackberry trees. However, symptoms were observed on neighboring, non-target hackberry trees, which had been in the leaf unfolding and expanding stages at the time of spraying. In 2009, three year old hackberry seedlings were treated with 1%, 10%, and 100% of the recommended field rate of acetochlor (Harness), S-metolachlor (Dual II Magnum), and dimethenamid (Outlook). Folded buds and two unfolding leaf developmental stages were present on seedlings. Another spray study was conducted on 32 mature hackberry trees from the provenance stand. A solution of 5608 mg a.i./L dimethenamid (Outlook) was applied to trees in the unfolding and/or expanding leaf stage. Treated trees represented four provenances. Image analysis was used to calculate seedling and mature tree leaf areas and estimate the seedling percentage of leaf tissue loss. Foliar damage was not significantly different between seedlings treated with water, 1%, or 10% of the field rate. Foliar damage was significantly different between seedlings treated with 1% or 100% of the field rate, and between seedlings treated with 10% or 100% of the field rate. Foliar damage in seedlings was not significantly different between the developmental stages. Additionally, symptoms of leaf tatters were observed on the treated mature hackberry. Future studies should focus on chloroacetamide concentrations above 10% of the recommended field rate.