2 resultados para RELAXATION-TIME
em Digital Commons @ DU | University of Denver Research
Resumo:
Substances containing unpaired electrons have been studied by electron paramagnetic resonance (EPR) for nearly 70 years. With continual development and enhancement of EPR techniques, questions have arisen regarding optimum method selection for a given sample based on its properties. In this work, radiation defects, natural lattice defects, solid organic radicals, radicals in solution, and spin-labeled proteins were analyzed using CW, pulse, and rapid scan EPR to compare methods. Studies of solid BDPA, EOe in quartz, Ns0 in diamond, and a-Si:H, showed that rapid scan could overcome many obstacles presented by other techniques, cementing rapid scan as an effective alternative to CW and pulse methods. Relaxation times of six nitroxide radicals were characterized from 0.25-34 GHz, guiding synthesis of improved nitroxides for in vivo imaging experiments. Processes contributing to T1 of DPPH in polystyrene were found through variable temperature measurements at X- and Q-band, resolving previously-reported discrepancies in relaxation properties and providing new insight into this commonly-used standard. In the history of EPR, the study of proteins is relatively new. Double electron-electron resonance (DEER) has emerged as a powerful technique for the study of amyloid fibrils, a class of protein aggregates implicated in a number of neurodegenerative disorders. Microtubule-associated protein tau forms fibrils linked to Alzheimerfs disease through seeded conversion of monomer. Self-assembly is mediated by the microtubule binding repeats in tau, and there are either three or four repeats present depending on the isoform. DEER was used to show that filaments of 3R and 4R tau are conformationally distinct and that 4R fibrils adopt a heterogeneous mixture of conformations. Populations of 4R fibril conformations, which were independently validated using a model system, can be modulated by introduction of mutations to the primary sequence or by varying fibril growth conditions. These findings provided unprecedented insights into the seed selection of tau monomers and established conformational compatibility as an important driving force in tau fibril propagation. Lastly, DEER acquisition was improved through addition of paramagnetic metal to spin-labeled protein, decreasing collection time, and through use of a novel spin label with increased T2, thereby lengthening the available acquisition window.
Resumo:
Rapid scan electron paramagnetic resonance (EPR) was developed in the Eaton laboratory at the University of Denver. Applications of rapid scan to wider spectra, such as for immobilized nitroxides, spin-labeled proteins, irradiated tooth and fingernail samples were demonstrated in this dissertation. The scan width has been increased from 55 G to 160 G. The signal to noise (S/N) improvement for slowly tumbling spin-labeled protein samples that is provided by rapid scan EPR will be highly advantageous for biophysical studies. With substantial improvement in S/N by rapid scan, the dose estimation for irradiated tooth enamels became more reliable than the traditional continuous wave (CW) EPR. An alternate approach of rapid scan, called field-stepped direct detection EPR, was developed to reconstruct wider EPR signals. A Mn2+ containing crystal was measured by field-stepped direct detection EPR, which had a spectrum more than 6000 G wide. Since the field-stepped direct detection extends the advantages of rapid scan to much wider scan ranges, this methodology has a great potential to replace the traditional CW EPR. With recent advances in digital electronics, a digital rapid scan spectrometer was built based on an arbitrary waveform generator (AWG), which can excite spins and detect EPR signals with a fully digital system. A near-baseband detection method was used to acquire the in-phase and quadrature signals in one physical channel. The signal was analyzed digitally to generate ideally orthogonal quadrature signals. A multiharmonic algorithm was developed that employed harmonics of the modulation frequencies acquired in the spectrometer transient mode. It was applied for signals with complicated lineshapes, and can simplify the selection of modulation amplitude. A digital saturation recovery system based on an AWG was built at X-band (9.6 GHz). To demonstrate performance of the system, the spin-lattice relaxation time of a fused quartz rod was measured at room temperature with fully digital excitation and detection.