7 resultados para sensitivity of returns

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Overexpression and amplification of the HER-2 oncogene in patients with breast cancer has correlated with early onset of metastasis, resistance to hormonal therapy and some forms of chemotherapy, and shortened survival. Therefore, evaluation of this putative prognostic or predictive factor seems critical. Because different antibodies are used for the detection of the 185-kd HER-2 oncoprotein, we studied the sensitivity of 3 frequently used antibodies. Immunohistochemistry results were correlated with gene amplification level as assessed by fluorescence in situ hybridization. Protein overexpression was found in 17.2% and 12.5% of cases using antibodies against the external (TAB250) and internal (CB11) domains of the protein, respectively, and in 38.0% of cases using a rabbit polyclonal antibody. Fluorescence in situ hybridization was successful in all 160 tumors, and amplification was found in 37 tumors (23.1%). The monoclonal antibody TAB250 had the lowest misclassification rate, 9.6% (sensitivity, 67%; specificity, 97.5%).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Tissue transglutaminase (t-TG) is the main autoantigen recognized by the endomysium antibodies (EMA) observed in patients with celiac disease (CD). The aim of the study was to assess an ELISA method for t-TG antibodies (t-TGA) with respect to EMA IF assay in pediatric and adult patients. METHODS: t-TGA were analyzed by ELISA in 220 sera samples: 82 patients with biopsy-proven untreated CD (23 adults and 59 children), 14 CD children on gluten-free diet, 18 asymptomatic relatives of CD patients, and 106 age-matched control patients with gluten-unrelated gastrointestinal diseases (58 adults and 48 children). Serum IgA EMA were tested on umbilical cord sections in all patients. RESULTS: The great majority (92.7%) of untreated CD patients (both adults and children) were t-TGA positive (values ranging from 20.1 to > 300 AU). None of the child control patients and only two out of 58 (3.4%) of the adults with unrelated gastrointestinal diseases had serum t-TGA positivity; two out of 18 first-degree relatives with biopsy-proved silent CD were t-TGA (as well as EMA) positive. Finally, two out of 14 CD children, assuming a gluten-free diet, had serum t-TGA (as well as EMA). A highly significant correlation (P < 0.001) was observed between t-TGA concentrations and EMA. t-TGA showed a sensitivity of 87% and 95%, a specificity of 97% and 100% for adults and children, respectively. CONCLUSION: The method is highly sensitive and specific in the diagnosis of CD and is promising as a tool for routine diagnostic use and population screening, especially in children.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A number of different interferon-gamma ELISpot protocols are in use in laboratories studying antigen-specific immune responses. It is therefore unclear how results from different assays compare, and what factors most significantly influence assay outcome. One such difference is that some laboratories use a short in vitro stimulation period of cells before they are transferred to the ELISpot plate; this is commonly done in the case of frozen cells, in order to enhance assay sensitivity. Other differences that may be significant include antibody coating of plates, the use of media with or without serum, the serum source and the number of cells added to the wells. The aim of this paper was to identify which components of the different ELISpot protocols influenced assay sensitivity and inter-laboratory variation. Four laboratories provided protocols for quantifying numbers of interferon-gamma spot forming cells in human peripheral blood mononuclear cells stimulated with Mycobacterium tuberculosis derived antigens. The differences in the protocols were compared directly. We found that several sources of variation in assay protocols can be eliminated, for example by avoiding serum supplementation and using AIM-V serum free medium. In addition, the number of cells added to ELISpot wells should also be standardised. Importantly, delays in peripheral blood mononuclear cell processing before stimulation had a marked effect on the number of detectable spot forming cells; processing delay thus should be minimised as well as standardised. Finally, a pre-stimulation culture period improved the sensitivity of the assay, however this effect may be both antigen and donor dependent. In conclusion, small differences in ELISpot protocols in routine use can affect the results obtained and care should be given to conditions selected for use in a given study. A pre-stimulation step may improve the sensitivity of the assay, particularly when cells have been previously frozen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Strict lifelong compliance to a gluten-free diet (GFD) minimizes the long-term risk of mortality, especially from lymphoma, in adult celiac disease (CD). Although serum IgA antitransglutaminase (IgA-tTG-ab), like antiendomysium (IgA-EMA) antibodies, are sensitive and specific screening tests for untreated CD, their reliability as predictors of strict compliance to and dietary transgressions from a GFD is not precisely known. We aimed to address this question in consecutively treated adult celiacs. METHODS: In a cross-sectional study, 95 non-IgA deficient adult (median age: 41 yr) celiacs on a GFD for at least 1 yr (median: 6 yr) were subjected to 1) a dietician-administered inquiry to pinpoint and quantify the number and levels of transgressions (classified as moderate or large, using as a cutoff value the median gluten amount ingested in the overall noncompliant patients of the series) over the previous 2 months, 2) a search for IgA-tTG-ab and -EMA, and 3) perendoscopic duodenal biopsies. The ability of both antibodies to discriminate celiacs with and without detected transgressions was described using receiver operating characteristic curves and quantified as to sensitivity and specificity, according to the level of transgressions. RESULTS: Forty (42%) patients strictly adhered to a GFD, 55 (58%) had committed transgressions, classified as moderate (< or = 18 g of gluten/2 months; median number 6) in 27 and large (>18 g; median number 69) in 28. IgA-tTG-ab and -EMA specificity (proportion of correct recognition of strictly compliant celiacs) was 0.97 and 0.98, respectively, and sensitivity (proportion of correct recognition of overall, moderate, and large levels of transgressions) was 0.52, 0.31, and 0.77, and 0.62, 0.37, and 0.86, respectively. IgA-tTG-ab and -EMA titers were correlated (p < 0.001) to transgression levels (r = 0.560 and R = 0.631, respectively) and one to another (p < 0.001) in the whole patient population (r = 0.834, N = 84) as in the noncompliant (r = 0.915, N = 48) group. Specificity and sensitivity of IgA-tTG-ab and IgA-EMA for recognition of total villous atrophy in patients under a GFD were 0.90 and 0.91, and 0.60 and 0.73, respectively. CONCLUSIONS: In adult CD patients on a GFD, IgA-tTG-ab are poor predictors of dietary transgressions. Their negativity is a falsely secure marker of strict diet compliance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the value of serum antitissue transglutaminase IgA antibodies (IgA-TTG) and IgA antiendomysial antibodies (IgA-EMA) in the diagnosis of coeliac disease in cohorts from different geographical areas in Europe. The setting allowed a further comparison between the antibody results and the conventional small-intestinal histology. METHODS: A total of 144 cases with coeliac disease [median age 19.5 years (range 0.9-81.4)], and 127 disease controls [median age 29.2 years (range 0.5-79.0)], were recruited, on the basis of biopsy, from 13 centres in nine countries. All biopsy specimens were re-evaluated and classified blindly a second time by two investigators. IgA-TTG were determined by ELISA with human recombinant antigen and IgA-EMA by an immunofluorescence test with human umbilical cord as antigen. RESULTS: The quality of the biopsy specimens was not acceptable in 29 (10.7%) of 271 cases and a reliable judgement could not be made, mainly due to poor orientation of the samples. The primary clinical diagnosis and the second classification of the biopsy specimens were divergent in nine cases, and one patient was initially enrolled in the wrong group. Thus, 126 coeliac patients and 106 controls, verified by biopsy, remained for final analysis. The sensitivity of IgA-TTG was 94% and IgA-EMA 89%, the specificity was 99% and 98%, respectively. CONCLUSIONS: Serum IgA-TTG measurement is effective and at least as good as IgA-EMA in the identification of coeliac disease. Due to a high percentage of poor histological specimens, the diagnosis of coeliac disease should not depend only on biopsy, but in addition the clinical picture and serology should be considered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Positive skin prick tests (SPT) for food allergens and specific IgE (sIgE) in serum indicate sensitization but do not enable distinction between sensitized but tolerant and clinically allergic patients. OBJECTIVE: Herein, we evaluate the clinical relevance of basophil activation tests (BATs) for peanut or egg allergy diagnosis. METHODS: Thirty-two peanut-allergic, 14 peanut-sensitized (sIgE(+) and/or SPT(+) to peanuts) but tolerant children and 29 controls with no history of an adverse reaction to peanuts were included. Similarly, 31 egg-allergic, 14 egg-sensitized children (sIgE(+) and/or SPT(+) to egg white) and 22 controls were studied. Flow cytometric analysis of CD63 expression or CD203c upregulation on basophils and the production of leukotrienes (LT) were performed in response to an in vitro crude peanut extract or ovalbumin (OVA) challenge. RESULTS: After in vitro peanut challenge, the basophils from peanut-allergic children showed significantly higher levels of activation than those from controls (P<0.001). After OVA challenge, a similar distinction (P<0.001) was observed between egg-allergics and controls. Interestingly, the majority of egg- or peanut-sensitized children failed to activate basophils, respectively, in response to OVA and peanut challenge. The sensitivity of the CD63, CD203c and LT assay was 86.7%, 89.5% and 76.0% with a specificity of 94.1%, 97.1% and 94.6% for peanut allergy diagnosis. The corresponding performances of BATs applied to egg allergy diagnosis were 88.9%, 62.5% and 77.8% for the sensitivity and 100%, 96.4% and 96.4% for the specificity. CONCLUSION: Neither conventional tests nor BATs are sensitive and specific enough to predict food allergy accurately. However, BATs may helpfully complete conventional tests, especially SPT, allowing improved discrimination between allergic and non-allergic individuals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Intracellular cytokine staining combined with flow cytometry is one of a number of assays designed to assess T-cell immune responses. It has the specific advantage of enabling the simultaneous assessment of multiple phenotypic, differentiation and functional parameters pertaining to responding T-cells, most notably, the expression of multiple effector cytokines. These attributes make the technique particularly suitable for the assessment of T-cell immune responses induced by novel tuberculosis vaccines in clinical trials. However, depending upon the particular nature of a given vaccine and trial setting, there are approaches that may be taken at different stages of the assay that are more suitable than other alternatives. In this paper, the Tuberculosis Vaccine Initiative (TBVI) TB Biomarker Working group reports on efforts to assess the conditions that will determine when particular assay approaches should be employed. We have found that choices relating to the use of fresh whole blood or peripheral blood mononuclear cells (PBMC) and frozen PBMC; use of serum-containing or serum-free medium; length of stimulation period and use of co-stimulatory antibodies can all affect the sensitivity of intracellular cytokine assays. In the case of sample material, frozen PBMC, despite some loss of sensitivity, may be more advantageous for batch analysis. We also recommend that for multi-site studies, common antibody panels, gating strategies and analysis approaches should be employed for better comparability.