3 resultados para heart ejection fraction

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: The potential cardiotoxicity of the doxorubicin-paclitaxel regimen, when paclitaxel is given shortly after the end of the anthracycline infusion, is an issue of concern, as suggested by small single institution Phase II studies. METHODS: In a large multicenter Phase III trial, 275 anthracycline naive metastatic breast carcinoma patients were randomized to receive either doxorubicin (60 mg/m(2)) followed 30 minutes later by paclitaxel (175 mg/m(2) 3-hour infusion; AT) or a standard doxorubicin-cyclophosphamide regimen (AC; 60/600 mg/m(2)). Both treatments were given once every 3 weeks for a maximum of six cycles. Close cardiac monitoring was implemented in the study design. RESULTS: Congestive heart failure (CHF) occurred in three patients in the AT arm and in one patient in the AC arm (P = 0.62). Decreases in left ventricular ejection fraction to below the limit of normal were documented in 33% AT and 19% AC patients and were not predictive of CHF development. CONCLUSIONS: AT is devoid of excessive cardiac risk among metastatic breast carcinoma patients, when the maximum planned cumulative dose of doxorubicin does not exceed 360 mg/m(2).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a heart-lung transplant recipient who presented with pulmonary tuberculosis (TB) 2.5 months after transplantation and then developed a paradoxical reaction after 4 months of adequate anti-TB treatment. She eventually recovered with anti-TB and high-dose steroid treatments. METHODS: Using sequential bronchoalveolar lavages, we assessed the inflammatory response in the lung and investigated the alveolar immune response against a Mycobacterium tuberculosis antigen. RESULTS: The paradoxical reaction was characterized by a massive infiltration of the alveolar space by M. tuberculosis antigen-specific CD4(+) T cells and by the presence of a CD4(-)CD8(-) T lymphocyte subpopulation bearing phenotypic markers (CD16(+)/56(+)) classically associated with NK cells. CONCLUSION: This case report illustrates that even solid organ transplant recipients receiving intense triple-drug immune suppression may be able to develop a paradoxical reaction during TB treatment. Transplant physicians should be aware of this phenomenon in order to differentiate it from treatment failure.