2 resultados para electrophysiology

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Microcephaly with or without chorioretinopathy, lymphedema or intellectual disability (MCLID) is an autosomal dominant condition. Mutations in KIF11 have been found to be causative in approximately 75% of cases. This study describes the ocular phenotype in patients with confirmed KIF11 mutations. Methods Standard ophthalmic examination and investigation including visual acuity, refraction and fundus examination was carried out in all patients. Fundus autofluorescence imaging (FAF) was performed in three patients, and four patients underwent spectral domain optical coherence tomography (OCT). Flash electroretinography (ERG) was performed in seven patients, and five underwent additional pattern electroretinography (PERG). Results The patients ranged in age from 2 to 10 years. Most presented with visual acuity loss. Fundus examination revealed lacunae of chorioretinal atrophy. Pigmentary macular changes and optic disc pallor were present in three of seven patients. Fundus autofluorescence demonstrated hypoautofluorescence at the macula in two of three patients. The lacunae of chorioretinal atrophy were hypoautofluorescent. The OCT showed atrophic maculae in three of four patients. Follow-up in one patient showed no deterioration of the vision over a 9-year period. The lesions appear not to be progressive on the follow-up imaging. Electrophysiology showed generalized rod and cone dysfunction and severe macular dysfunction. Inner retinal dysfunction was evident in three of seven patients. Conclusions Patients with KIF11 mutations show a specific ocular phenotype with variable expressivity and intrafamilial variability. Macular atrophy and dysfunction have not been consistently documented before. The fundus lesions appear non-progressive. The findings assist in providing an accurate diagnosis and thus improving the management and follow-up of patients with this syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In an experimental model, variable and intermittent contact force (CF) resulted in a significant decrease in lesion volume. In humans, variability of CF during pulmonary vein isolation has not been characterized. Methods and Results-In 20 consecutive patients undergoing CF-guided circumferential pulmonary vein isolation, 914 radiofrequency applications (530 in sinus rhythm and 384 in atrial fibrillation) were analyzed. The variability of the 60% CF range (CF60%) was 17 ± 9.6 g. Hundred seventy-one (19%) applications were delivered with constant, 717 (78%) with variable, and 26 (3%) with intermittent CF. The mean CF and force-time integral were significantly higher during applications with variable than with intermittent or constant CF. There was no significant difference in CF variability, CF60% variability, and force-time integral between applications delivered in sinus rhythm and atrial fibrillation. The main reasons for CF variability were systolo-diastolic heart movement (29%) and respiration (27%). In 10 additional patients, during adenosine-induced atrioventricular block, the minimum CF significantly increased at 19 sites (5.3 ± 4.4 versus 13.4 ± 5.9 g; P < 0.001) and at 16 sites intermittent or variable CF became constant. At only 1 site systolo-diastolic movement remained the main reason for variable CF. Conclusions-CF during pulmonary vein isolation remains highly variable despite efforts to optimize contact. CF and CF parameters were similar during sinus rhythm and atrial fibrillation. The main reasons for CF variability are systolodiastolic heart movement and respiration. The systolo-diastolic peaks and nadirs of CF are because of ventricular contractions at the large majority of pulmonary vein isolation sites.