2 resultados para Tool switches

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The detection of latent tuberculosis infection (LTBI) is a major component of tuberculosis (TB) control strategies. In addition to the tuberculosis skin test (TST), novel blood tests, based on in vitro release of IFN-gamma in response to Mycobacterium tuberculosis-specific antigens ESAT-6 and CFP-10 (IGRAs), are used for TB diagnosis. However, neither IGRAs nor the TST can separate acute TB from LTBI, and there is concern that responses in IGRAs may decline with time after infection. We have therefore evaluated the potential of the novel antigen heparin-binding hemagglutinin (HBHA) for in vitro detection of LTBI. METHODOLOGY AND PRINCIPAL FINDINGS: HBHA was compared to purified protein derivative (PPD) and ESAT-6 in IGRAs on lymphocytes drawn from 205 individuals living in Belgium, a country with low TB prevalence, where BCG vaccination is not routinely used. Among these subjects, 89 had active TB, 65 had LTBI, based on well-standardized TST reactions and 51 were negative controls. HBHA was significantly more sensitive than ESAT-6 and more specific than PPD for the detection of LTBI. PPD-based tests yielded 90.00% sensitivity and 70.00% specificity for the detection of LTBI, whereas the sensitivity and specificity for the ESAT-6-based tests were 40.74% and 90.91%, and those for the HBHA-based tests were 92.06% and 93.88%, respectively. The QuantiFERON-TB Gold In-Tube (QFT-IT) test applied on 20 LTBI subjects yielded 50% sensitivity. The HBHA IGRA was not influenced by prior BCG vaccination, and, in contrast to the QFT-IT test, remote (>2 years) infections were detected as well as recent (<2 years) infections by the HBHA-specific test. CONCLUSIONS: The use of ESAT-6- and CFP-10-based IGRAs may underestimate the incidence of LTBI, whereas the use of HBHA may combine the operational advantages of IGRAs with high sensitivity and specificity for latent infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Patients with end-stage renal disease (ESRD) and latently infected with Mycobacterium tuberculosis (LTBI) are at higher risk to develop tuberculosis (TB) than healthy subjects. Interferon-gamma release assays (IGRAs) were reported to be more sensitive than tuberculin skin tests for the detection of infected individuals in dialysis patients.Methods:On 143 dialysis patients prospectively enrolled, we compared the results from the QuantiFERON®-TB Gold assay (QFT), to those of an IGRA in response to in vitro stimulation of circulating mononuclear cells with the mycobacterial latency antigen Heparin-Binding Haemagglutinin purified from Mycobacterium bovis BCG (native HBHA, nHBHA).Results:Seven patients had a past history of active TB and 1 had an undetermined result with both IGRAs. Among the other 135 patients, 94 had concordant results with the QFT and nHBHA-IGRA, 40.0% being negative and therefore not latently infected, and 29.6% being positive and thus LTBI. Discrepant results between these tests were found for 36 patients positive only with the nHBHA-IGRA and 5 only with the QFT.Conclusions:The nHBHA-IGRA is more sensitive than the QFT for the detection of LTBI dialysis patients, and follow-up of the patients will allow us to define the clinical significance of discrepant results between the nHBHA-IGRA and the QFT. © 2013 Dessein et al.