3 resultados para Quality Evaluation

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective Describe the methodology and selection of quality indicators (QI) to be implemented in the EFFECT (EFFectiveness of Endometrial Cancer Treatment) project. EFFECT aims to monitor the variability in Quality of Care (QoC) of uterine cancer in Belgium, to compare the effectiveness of different treatment strategies to improve the QoC and to check the internal validity of the QI to validate the impact of process indicators on outcome. Methods A QI list was retrieved from literature, recent guidelines and QI databases. The Belgian Healthcare Knowledge Center methodology was used for the selection process and involved an expert's panel rating the QI on 4 criteria. The resulting scores and further discussion resulted in a final QI list. An online EFFECT module was developed by the Belgian Cancer Registry including the list of variables required for measuring the QI. Three test phases were performed to evaluate the relevance, feasibility and understanding of the variables and to test the compatibility of the dataset. Results 138 QI were considered for further discussion and 82 QI were eligible for rating. Based on the rating scores and consensus among the expert's panel, 41 QI were considered measurable and relevant. Testing of the data collection enabled optimization of the content and the user-friendliness of the dataset and online module. Conclusions This first Belgian initiative for monitoring the QoC of uterine cancer indicates that the previously used QI selection methodology is reproducible for uterine cancer. The QI list could be applied by other research groups for comparison. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Serologic methods have been used widely to test for celiac disease and have gained importance in diagnostic definition and in new epidemiologic findings. However, there is no standardization, and there are no reference protocols and materials. METHODS: The European working group on Serological Screening for Celiac Disease has defined robust noncommercial test protocols for immunoglobulin (Ig)G and IgA gliadin antibodies and for IgA autoantibodies against endomysium and tissue transglutaminase. Standard curves were linear in the decisive range, and intra-assay variation coefficients were less than 5% to 10%. Calibration was performed with a group reference serum. Joint cutoff limits were used. Seven laboratories took part in the final collaborative study on 252 randomized sera classified by histology (103 pediatric and adult patients with active celiac disease, 89 disease control subjects, and 60 blood donors). RESULTS: IgA autoantibodies against endomysium and tissue transglutaminase rendered superior sensitivity (90% and 93%, respectively) and specificity (99% and 95%, respectively) over IgA and IgG gliadin antibodies. Tissue transglutaminase antibody testing showed superior receiver operating characteristic performance compared with gliadin antibodies. The K values for interlaboratory reproducibility showed superiority for IgA endomysium (0.93) in comparison with tissue transglutaminase antibodies (0.83) and gliadin antibodies (0.82 for IgG, 0.62 for IgA). CONCLUSIONS: Basic criteria of standardization and quality assessment must be fulfilled by any given test protocol proposed for serologic investigation of celiac disease. The working group has produced robust test protocols and reference materials available for standardization to further improve reliability of serologic testing for celiac disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.