2 resultados para New left

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While the number of traditional laptops and computers sold has dipped slightly year over year, manufacturers have developed new hybrid laptops with touch screens to build on the tactile trend. This market is moving quickly to make touch the rule rather than the exception and the sales of these devices have tripled since the launch of Windows 8 in 2012, to reach more than sixty million units sold in 2015. Unlike tablets, that benefit from easy-to-use applications specially designed for tactile interactions, hybrid laptops are intended to be used with regular user-interfaces. Hence, one could ask whether tactile interactions are suited for every task and activity performed with such interfaces. Since hybrid laptops are increasingly used in educational situations, this study focuses on information search tasks which are commonly performed for learning purposes. It is hypothesized that tasks that require complex and/or less common gestures will increase user's cognitive load and impair task performance in terms of efficacy and efficiency. A study was carried out in a usability laboratory with 30 participants for whom prior experience with tactile devices has been controlled. They were asked to perform information search tasks on an online encyclopaedia by using only the touch screen of and hybrid laptop. Tasks were selected with respect to their level of cognitive demand (amount of information that had to be maintained in working memory) and the complexity of gestures needed (left and/or right clicks, zoom, text selection and/or input.), and grouped into 4 sets accordingly. Task performance was measured by the number of tasks succeeded (efficacy) and time spent on each task (efficiency). Perceived cognitive load was assessed thanks to a questionnaire given after each set of tasks. An eye tracking device was used to monitor users' attention allocation and to provide objective cognitive load measures based on pupil dilation and the Index of Cognitive Activity. Each experimental run took approximately one hour. The results of this within-subjects design indicate that tasks involving complex gestures led to a lower efficacy, especially when the tasks were cognitively demanding. Regarding efficacy, there is no significant differences between sets of tasks excepted for tasks with low cognitive demand and complex gestures that required more time to be achieved. Surprisingly, users that declared the biggest experience with tactile devices spent more time than less frequent users. Cognitive load measures indicate that participants reported having devoted more mental effort in the interaction when they had to use complex gestures.