13 resultados para Lacrimal duct obstruction diagnosis
em DI-fusion - The institutional repository of Université Libre de Bruxelles
Resumo:
Photodynamic therapy (PDT) is a new therapeutic approach for the palliative treatment of malignant bile duct obstruction. In this study, we designed photosensitizer-embedded self-expanding nonvascular metal stent (PDT-stent) which allows repeatable photodynamic treatment of cholangiocarcinoma without systemic injection of photosensitizer. Polymeric photosensitizer (pullulan acetate-conjugated pheophorbide A; PPA) was incorporated in self-expanding nonvascular metal stent. Residence of PPA in the stent was estimated in buffer solution and subcutaneous implantation on mouse. Photodynamic activity of PDT-stent was evaluated through laserexposure on stent-layered tumor cell lines, HCT-116 tumor-xenograft mouse models and endoscopic intervention of PDT-stent on bile duct of mini pigs. Photo-fluorescence imaging of the PDT-stent demonstrated homogeneous embedding of polymeric Pheo-A (PPA) on stent membrane. PDT-stent sustained its photodynamic activities at least for 2 month. And which implies repeatable endoscopic PDT is possible after stent emplacement. The PDT-stent after light exposure successfully generated cytotoxic singlet oxygen in the surrounding tissues, inducing apoptotic degradation of tumor cells and regression of xenograft tumors on mouse models. Endoscopic biliary in-stent photodynamic treatments on minipigs also suggested the potential efficacy of PDT-stent on cholangiocarcinoma. In vivo and in vitro studies revealed our PDT-stent, allows repeatable endoscopic biliary PDT, has the potential for the combination therapy (stent plus PDT) of cholangiocarcinoma. © 2014 Elsevier Ltd.
Resumo:
OBJECTIVE: To investigate the value of serum antitissue transglutaminase IgA antibodies (IgA-TTG) and IgA antiendomysial antibodies (IgA-EMA) in the diagnosis of coeliac disease in cohorts from different geographical areas in Europe. The setting allowed a further comparison between the antibody results and the conventional small-intestinal histology. METHODS: A total of 144 cases with coeliac disease [median age 19.5 years (range 0.9-81.4)], and 127 disease controls [median age 29.2 years (range 0.5-79.0)], were recruited, on the basis of biopsy, from 13 centres in nine countries. All biopsy specimens were re-evaluated and classified blindly a second time by two investigators. IgA-TTG were determined by ELISA with human recombinant antigen and IgA-EMA by an immunofluorescence test with human umbilical cord as antigen. RESULTS: The quality of the biopsy specimens was not acceptable in 29 (10.7%) of 271 cases and a reliable judgement could not be made, mainly due to poor orientation of the samples. The primary clinical diagnosis and the second classification of the biopsy specimens were divergent in nine cases, and one patient was initially enrolled in the wrong group. Thus, 126 coeliac patients and 106 controls, verified by biopsy, remained for final analysis. The sensitivity of IgA-TTG was 94% and IgA-EMA 89%, the specificity was 99% and 98%, respectively. CONCLUSIONS: Serum IgA-TTG measurement is effective and at least as good as IgA-EMA in the identification of coeliac disease. Due to a high percentage of poor histological specimens, the diagnosis of coeliac disease should not depend only on biopsy, but in addition the clinical picture and serology should be considered.
Resumo:
SCOPUS: ar.j
Resumo:
info:eu-repo/semantics/nonPublished
Resumo:
Congrès du GIRSO, Lille, avril 2011
Resumo:
BACKGROUND: The etiologic diagnosis of community-acquired pneumonia (CAP) remains challenging in children because blood cultures have low sensitivity. Novel approaches are needed to confirm the role of Streptococcus pneumoniae. METHODS: In this study, pneumococcal aetiology was determined by serology using a subset of blood samples collected during a prospective multicentre observational study of children <15 years of age hospitalised in Belgium with X-ray-confirmed CAP. Blood samples were collected at admission and 3-4 weeks later. Pneumococcal (P)-CAP was defined in the presence of a positive blood or pleural fluid culture. Serotyping of Streptococcus pneumoniae isolates was done with the Quellung reaction. Serological diagnosis was assessed for nine serotypes using World Health Organization validated IgG and IgA serotype-specific enzyme-linked immunosorbent assays (ELISAs). RESULTS: Paired admission/convalescent sera from 163 children were evaluated by ELISA (35 with proven P-CAP and 128 with non proven P-CAP). ELISA detected pneumococci in 82.8% of patients with proven P-CAP. The serotypes identified were the same as with the Quellung reaction in 82% and 59% of cases by IgG ELISA and IgA ELISA, respectively. Overall, ELISA identified a pneumococcal aetiology in 55% of patients with non-proven P-CAP. Serotypes 1 (51.6%), 7F (19%), and 5 (15.7%) were the most frequent according to IgG ELISA. CONCLUSIONS: In conclusion, the serological assay allows recognition of pneumococcal origin in 55% of CAP patients with negative culture. This assay should improve the diagnosis of P-CAP in children and could be a useful tool for future epidemiological studies on childhood CAP etiology.
Resumo:
Background:Diagnosis of childhood active tuberculosis (aTB) or latent Mycobacterium tuberculosis (Mtb) infection (LTBI) remains a challenge, and replacement of tuberculin skin tests (TST) by commercialized interferon-gamma release assays (IGRA) is not currently recommended.Methods:266 children between 1 month and 15 years of age, 214 being at risk of recent Mtb infection and 51 being included as controls, were prospectively enrolled. According results of clinical evaluation, TST, chest X-Ray and microbiology, children were classified as non-infected, LTBI or aTB. Long-incubation time PPD-, ESAT-6-, and CFP-10-IGRA were performed and evaluated for their accuracy to correctly classify the children.Results:Whereas both TST and PPD-IGRA were suboptimal to detect aTB, combining CFP-10-IGRA with TST or with PPD-IGRA allowed us to detect all the children with aTB, with 96% specificity for children who were positive for CFP-10-IGRA. Moreover, combination of CFP-10- and PPD-IGRA also detected 96% of children classified as LTBI, but a strong IFN-γ response to CFP-10 (>500 pg/ml) was highly suggestive of aTB at least among children less than 3 years old.Conclusions:Long-incubation time CFP-10- and PPD-IGRA should help the clinicians to identify quickly aTB or LTBI in young children.
Resumo:
info:eu-repo/semantics/published
Resumo:
info:eu-repo/semantics/nonPublished
Resumo:
info:eu-repo/semantics/nonPublished
Resumo:
info:eu-repo/semantics/nonPublished
Resumo:
info:eu-repo/semantics/nonPublished
Resumo:
BACKGROUND: Positive skin prick tests (SPT) for food allergens and specific IgE (sIgE) in serum indicate sensitization but do not enable distinction between sensitized but tolerant and clinically allergic patients. OBJECTIVE: Herein, we evaluate the clinical relevance of basophil activation tests (BATs) for peanut or egg allergy diagnosis. METHODS: Thirty-two peanut-allergic, 14 peanut-sensitized (sIgE(+) and/or SPT(+) to peanuts) but tolerant children and 29 controls with no history of an adverse reaction to peanuts were included. Similarly, 31 egg-allergic, 14 egg-sensitized children (sIgE(+) and/or SPT(+) to egg white) and 22 controls were studied. Flow cytometric analysis of CD63 expression or CD203c upregulation on basophils and the production of leukotrienes (LT) were performed in response to an in vitro crude peanut extract or ovalbumin (OVA) challenge. RESULTS: After in vitro peanut challenge, the basophils from peanut-allergic children showed significantly higher levels of activation than those from controls (P<0.001). After OVA challenge, a similar distinction (P<0.001) was observed between egg-allergics and controls. Interestingly, the majority of egg- or peanut-sensitized children failed to activate basophils, respectively, in response to OVA and peanut challenge. The sensitivity of the CD63, CD203c and LT assay was 86.7%, 89.5% and 76.0% with a specificity of 94.1%, 97.1% and 94.6% for peanut allergy diagnosis. The corresponding performances of BATs applied to egg allergy diagnosis were 88.9%, 62.5% and 77.8% for the sensitivity and 100%, 96.4% and 96.4% for the specificity. CONCLUSION: Neither conventional tests nor BATs are sensitive and specific enough to predict food allergy accurately. However, BATs may helpfully complete conventional tests, especially SPT, allowing improved discrimination between allergic and non-allergic individuals.