5 resultados para Evaluation of the results of therapeutic interventions
em DI-fusion - The institutional repository of Université Libre de Bruxelles
Resumo:
PURPOSE: Overall survival (OS) can be observed only after prolonged follow-up, and any potential effect of first-line therapies on OS may be confounded by the effects of subsequent therapy. We investigated whether tumor response, disease control, progression-free survival (PFS), or time to progression (TTP) could be considered a valid surrogate for OS to assess the benefits of first-line therapies for patients with metastatic breast cancer. PATIENTS AND METHODS: Individual patient data were collected on 3,953 patients in 11 randomized trials that compared an anthracycline (alone or in combination) with a taxane (alone or in combination with an anthracycline). Surrogacy was assessed through the correlation between the end points as well as through the correlation between the treatment effects on the end points. RESULTS: Tumor response (survival odds ratio [OR], 6.2; 95% CI, 5.3 to 7.0) and disease control (survival OR, 5.5; 95% CI, 4.8 to 6.3) were strongly associated with OS. PFS (rank correlation coefficient, 0.688; 95% CI, 0.686 to 0.690) and TTP (rank correlation coefficient, 0.682; 95% CI, 0.680 to 0.684) were moderately associated with OS. Response log ORs were strongly correlated with PFS log hazard ratios (linear coefficient [rho], 0.96; 95% CI, 0.73 to 1.19). Response and disease control log ORs and PFS and TTP log hazard ratios were poorly correlated with log hazard ratios for OS, but the confidence limits of rho were too wide to be informative. CONCLUSION: No end point could be demonstrated as a good surrogate for OS in these trials. Tumor response may be an acceptable surrogate for PFS.
Resumo:
BACKGROUND: The etiologic diagnosis of community-acquired pneumonia (CAP) remains challenging in children because blood cultures have low sensitivity. Novel approaches are needed to confirm the role of Streptococcus pneumoniae. METHODS: In this study, pneumococcal aetiology was determined by serology using a subset of blood samples collected during a prospective multicentre observational study of children <15 years of age hospitalised in Belgium with X-ray-confirmed CAP. Blood samples were collected at admission and 3-4 weeks later. Pneumococcal (P)-CAP was defined in the presence of a positive blood or pleural fluid culture. Serotyping of Streptococcus pneumoniae isolates was done with the Quellung reaction. Serological diagnosis was assessed for nine serotypes using World Health Organization validated IgG and IgA serotype-specific enzyme-linked immunosorbent assays (ELISAs). RESULTS: Paired admission/convalescent sera from 163 children were evaluated by ELISA (35 with proven P-CAP and 128 with non proven P-CAP). ELISA detected pneumococci in 82.8% of patients with proven P-CAP. The serotypes identified were the same as with the Quellung reaction in 82% and 59% of cases by IgG ELISA and IgA ELISA, respectively. Overall, ELISA identified a pneumococcal aetiology in 55% of patients with non-proven P-CAP. Serotypes 1 (51.6%), 7F (19%), and 5 (15.7%) were the most frequent according to IgG ELISA. CONCLUSIONS: In conclusion, the serological assay allows recognition of pneumococcal origin in 55% of CAP patients with negative culture. This assay should improve the diagnosis of P-CAP in children and could be a useful tool for future epidemiological studies on childhood CAP etiology.
Resumo:
Measurement of antigen-specific T cell responses is an adjunctive parameter to evaluate protection induced by a previous Bordetella pertussis infection or vaccination. The assessment of T cell responses is technically complex and usually performed on fresh peripheral blood mononuclear cells (PBMC). The objective of this study was to identify simplified methods to assess pertussis specific T cell responses and verify if these assays could be performed using frozen/thawed (frozen) PBMC. Three read-outs to measure proliferation were compared: the fluorescent dye 5,6-carboxylfluorescein diacetate succinimidyl ester (CFSE) dilution test, the number of blast cells defined by physical parameters, and the incorporation of (3)H-thymidine. The results of pertussis-specific assays performed on fresh PBMC were compared to the results on frozen PBMC from the same donor. High concordance was obtained when the results of CFSE and blast read-outs were compared, an encouraging result since blast analysis allows the identification of proliferating cells and does not require any use of radioactive tracer as well as any staining. The results obtained using fresh and frozen PBMC from the same donor in the different T cell assays, including IFNγ and TNFα cytokine production, did not show significant differences, suggesting that a careful cryopreservation process of PBMC would not significantly influence T cell response evaluation. Adopting blast analysis and frozen PBMC, the possibility to test T cell responses is simplified and might be applied in population studies, providing for new instruments to better define correlates of protection still elusive in pertussis.
Resumo:
Objective Describe the methodology and selection of quality indicators (QI) to be implemented in the EFFECT (EFFectiveness of Endometrial Cancer Treatment) project. EFFECT aims to monitor the variability in Quality of Care (QoC) of uterine cancer in Belgium, to compare the effectiveness of different treatment strategies to improve the QoC and to check the internal validity of the QI to validate the impact of process indicators on outcome. Methods A QI list was retrieved from literature, recent guidelines and QI databases. The Belgian Healthcare Knowledge Center methodology was used for the selection process and involved an expert's panel rating the QI on 4 criteria. The resulting scores and further discussion resulted in a final QI list. An online EFFECT module was developed by the Belgian Cancer Registry including the list of variables required for measuring the QI. Three test phases were performed to evaluate the relevance, feasibility and understanding of the variables and to test the compatibility of the dataset. Results 138 QI were considered for further discussion and 82 QI were eligible for rating. Based on the rating scores and consensus among the expert's panel, 41 QI were considered measurable and relevant. Testing of the data collection enabled optimization of the content and the user-friendliness of the dataset and online module. Conclusions This first Belgian initiative for monitoring the QoC of uterine cancer indicates that the previously used QI selection methodology is reproducible for uterine cancer. The QI list could be applied by other research groups for comparison. © 2013 Elsevier Inc.
Resumo:
Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.