2 resultados para Artery Disease

em DI-fusion - The institutional repository of Université Libre de Bruxelles


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The impact of aromatase inhibitors (AIs) on non-cancer-related outcomes, which are known to be affected by oestrogens, has become increasingly important in postmenopausal women with hormone-dependent breast cancer. So far, data related to the effect of AIs on lipid profile in postmenopausal women is scarce. This study, as a companion substudy of an EORTC phase II trial (10951), evaluated the impact of exemestane, a steroidal aromatase inactivator, on the lipid profile of postmenopausal metastatic breast cancer (MBC) patients. PATIENTS AND METHODS: The EORTC trial 10951 randomised 122 postmenopausal breast cancer patients to exemestane (E) 25 mg (n = 62) or tamoxifen (T) 20 mg (n = 60) once daily as a first-line treatment in the metastatic setting. Exemestane showed promising results in all the primary efficacy end points of the trial (response rate, clinical benefit rate and response duration), and it was well tolerated with low incidence of serious toxicity. As a secondary end point of this phase II trial, serum triglycerides (TRG), high-density lipoprotein cholesterol (HDL), total cholesterol (TC), lipoprotein a (Lip a), and apolipoproteins (Apo) B and A1 were measured at baseline and while on therapy (at 8, 24 and 48 weeks) to assess the impact of exemestane and tamoxifen on serum lipid profiles. Of the 122 randomised patients, those who had baseline and at least one other lipid assessment are included in the present analysis. The patients who received concomitant drugs that could affect lipid profile are included only if these drugs were administered throughout the study treatment. Increase or decrease in lipid parameters within 20% of baseline were considered as non-significant and thus unchanged. RESULTS: Seventy-two patients (36 in both arms) were included in the statistical analysis. The majority of patients had abnormal TC and normal TRG, HDL, Apo A1, Apo B and Lip a levels at baseline. Neither exemestane nor tamoxifen had adverse effects on TC, HDL, Apo A1, Apo B or Lip a levels at 8, 24 and 48 weeks of treatment. Exemestane and tamoxifen had opposite effects on TRG levels: exemestane lowered while tamoxifen increased TRG levels over time. There were too few patients with normal baseline TC and abnormal TRG, HDL, Apo A1, Apo B and Lip a levels to allow for assessment of E's impact on these subsets. The atherogenic risk determined by Apo A1:Apo B and TC:HDL ratios remained unchanged throughout the treatment period in both the E and T arms. CONCLUSIONS: Overall, exemestane has no detrimental effect on cholesterol levels and the atherogenic indices, which are well-known risk factors for coronary artery disease. In addition, it has a beneficial effect on TRG levels. These data, coupled with E's excellent efficacy and tolerability, support further exploration of its potential in the metastatic, adjuvant and chemopreventive setting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.