3 resultados para analytical study

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes extended nonlinear analytical models, third-order models, of compliant parallelogram mechanisms. These models are capable of capturing the accurate effects from the very large axial force within the transverse motion range of 10% of the beam length through incorporating the terms associated with the high-order (up to third-order) axial force. Firstly, the free-body diagram method is employed to derive the nonlinear analytical model for a basic compliant parallelogram mechanism based on load-displacement relations of a single beam, geometry compatibility conditions, and load-equilibrium conditions. The procedures for the forward solutions and inverse solutions are described. Nonlinear analytical models for guided compliant multi-beam parallelogram mechanisms are then obtained. A case study of the compound compliant parallelogram mechanism, composed of two basic compliant parallelogram mechanisms in symmetry, is further implemented. This work intends to estimate the internal axial force change, the transverse force change, and the transverse stiffness change with the transverse motion using the proposed third-order model in comparison with the first-order model proposed in the prior art. In addition, FEA (finite element analysis) results validate the accuracy of the third-order model for a typical example. It is shown that in the case study the slenderness ratio affects the result discrepancy between the third-order model and the first-order model significantly, and the third-order model can illustrate a non-monotonic transverse stiffness curve if the beam is thin enough.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article explores Ulrich Beck’s theorisation of risk society through focusing on the way in which the risk of Bt cotton is legitimated by six cultivators in Bantala, a village in Warangal, Andhra Pradesh, in India. The fieldwork for this study was conducted between June 2010 and March 2011, a duration chosen to coincide with a cotton season. The study explores the experience of the cultivators using the ‘categories of legitimation’ defined by Van Leeuwen. These are authorisation, moral evaluation, rationalisation and mythopoesis. As well as permitting an exploration of the legitimation of Bt cotton by cultivators themselves within the high-risk context of the Indian agrarian crisis, the categories also serve as an analytical framework with which to structure a discourse analysis of participant perspectives. The study examines the complex trade-off, which Renn argues the legitimation of ambiguous risk, such as that associated with Bt technology, entails. The research explores the way in which legitimation of the technology is informed by wider normative conceptualisations of development. This highlights that, in a context where indebtedness is strongly linked to farmer suicides, the potential of Bt cotton for poverty alleviation is traded against the uncertainty associated with the technology’s risks, which include its purported links to animal deaths. The study highlights the way in which the wider legitimation of a neoliberal approach to development in Andhra Pradesh serves to reinforce the choice of Bt cotton, and results in a depoliticisation of risk in Bantala. The research indicates, however, that this trade-off is subject to change over time, as economic benefits wane and risks accumulate. It also highlights the need for caution in relation to the proposed extension of Bt technology to food crops, such as Bt brinjal (aubergine).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.