18 resultados para Technology for health
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
The work presented in this thesis described the development of low-cost sensing and separation devices with electrochemical detections for health applications. This research employs macro, micro and nano technology. The first sensing device developed was a tonerbased micro-device. The initial development of microfluidic devices was based on glass or quartz devices that are often expensive to fabricate; however, the introduction of new types of materials, such as plastics, offered a new way for fast prototyping and the development of disposable devices. One such microfluidic device is based on the lamination of laser-printed polyester films using a computer, printer and laminator. The resulting toner-based microchips demonstrated a potential viability for chemical assays, coupled with several detection methods, particularly Chip-Electrophoresis-Chemiluminescence (CE-CL) detection which has never been reported in the literature. Following on from the toner-based microchip, a three-electrode micro-configuration was developed on acetate substrate. This is the first time that a micro-electrode configuration made from gold; silver and platinum have been fabricated onto acetate by means of patterning and deposition techniques using the central fabrication facilities in Tyndall National Institute. These electrodes have been designed to facilitate the integration of a 3- electrode configuration as part of the fabrication process. Since the electrodes are on acetate the dicing step can automatically be eliminated. The stability of these sensors has been investigated using electrochemical techniques with excellent outcomes. Following on from the generalised testing of the electrodes these sensors were then coupled with capillary electrophoresis. The final sensing devices were on a macro scale and involved the modifications of screenprinted electrodes. Screen-printed electrodes (SPE) are generally seen to be far less sensitive than the more expensive electrodes including the gold, boron-doped diamond and glassy carbon electrodes. To enhance the sensitivity of these electrodes they were treated with metal nano-particles, gold and palladium. Following on from this, another modification was introduced. The carbonaceous material carbon monolith was drop-cast onto the SPE and then the metal nano-particles were electrodeposited onto the monolith material
Resumo:
Background: The management of childhood obesity is challenging. Aims: Thesis, i) reviews the evidence for lifestyle treatment of obesity, ii) explores cardiometabolic burden in childhood obesity, iii) explores whether changes in body composition predicts change in insulin sensitivity (IS), iv) develops and evaluates a lifestyle obesity intervention; v) develops a mobile health application for obesity treatment and vi) tests the application in a clinical trial. Methods: In Study 1, systematic reviews and meta-analyses of the 12‐month effects of lifestyle and mHealth interventions were conducted. In Study 2, the prevalence of cardiometabolic burden was estimated in a consecutive series of 267 children. In Study 3, body composition was estimated with bioelectrical impedance analysis (BIA) and dual x-ray absorptiometry (DXA) and linear regression analyses were used to estimate the extent to which each methods predicted change in IS. Study 4 describes the development of the Temple Street W82GO Healthy Lifestyle intervention for clinical obesity in children and a controlled study of treatment effect in 276 children is reported. Study 5 describes the development and testing of the Reactivate Mobile Obesity Application. Study 6 outlines the development and preliminary report from a clinical effectiveness trial of Reactivate. Results: In Study 1, meta--‐analyses BMI SDS changed by -0.16 (-0.24,‐0.07, p<0.01) and -0.03 (-0.13, 0.06, p=0.48). In study 2, cardiometabolic comorbidities were common (e.g. hypertension in 49%) and prevalence increased as obesity level increased. In Study 3, BC changes significantly predicted changes in IS. In Study 4, BMI SDS was significantly reduced in W82GO compared to controls (p<0.001). In Study 5, the Reactivate application had good usability indices and preliminary 6‐month process report data from Study 6, revealed a promising effect for Reactivate. Conclusions: W82GO and Reactivate are promising forms of treatment.
Resumo:
Adequate hand-washing has been shown to be a critical activity in preventing the transmission of infections such as MRSA in health-care environments. Hand-washing guidelines published by various health-care related institutions recommend a technique incorporating six hand-washing poses that ensure all areas of the hands are thoroughly cleaned. In this paper, an embedded wireless vision system (VAMP) capable of accurately monitoring hand-washing quality is presented. The VAMP system hardware consists of a low resolution CMOS image sensor and FPGA processor which are integrated with a microcontroller and ZigBee standard wireless transceiver to create a wireless sensor network (WSN) based vision system that can be retargeted at a variety of health care applications. The device captures and processes images locally in real-time, determines if hand-washing procedures have been correctly undertaken and then passes the resulting high-level data over a low-bandwidth wireless link. The paper outlines the hardware and software mechanisms of the VAMP system and illustrates that it offers an easy to integrate sensor solution to adequately monitor and improve hand hygiene quality. Future work to develop a miniaturized, low cost system capable of being integrated into everyday products is also discussed.
Resumo:
This article examines some preliminary tests which were performed in order to evaluate the best electrode configuration (width and spacing) for cell culture analyses. Biochips packaged with indium tin oxide (ITO) interdigitated electrodes (IDEs) were used to perform impedance measurements on A549 cells cultured on the surface of the biochip. Several tests were carried out using a 10 mM solution of Sodium Chloride (NaCl), cell medium and the cell culture itself to characterize some of the configurations already fabricated in the facilities at Tyndall National Institute.
Resumo:
Emerging healthcare applications can benefit enormously from recent advances in pervasive technology and computing. This paper introduces the CLARITY Modular Ambient Health and Wellness Measurement Platform:, which is a heterogeneous and robust pervasive healthcare solution currently under development at the CLARITY Center for Sensor Web Technologies. This intelligent and context-aware platform comprises the Tyndall Wireless Sensor Network prototyping system, augmented with an agent-based middleware and frontend computing architecture. The key contribution of this work is to highlight how interoperability, expandability, reusability and robustness can be manifested in the modular design of the constituent nodes and the inherently distributed nature of the controlling software architecture.Emerging healthcare applications can benefit enormously from recent advances in pervasive technology and computing. This paper introduces the CLARITY Modular Ambient Health and Wellness Measurement Platform:, which is a heterogeneous and robust pervasive healthcare solution currently under development at the CLARITY Center for Sensor Web Technologies. This intelligent and context-aware platform comprises the Tyndall Wireless Sensor Network prototyping system, augmented with an agent-based middleware and frontend computing architecture. The key contribution of this work is to highlight how interoperability, expandability, reusability and robustness can be manifested in the modular design of the constituent nodes and the inherently distributed nature of the controlling software architecture.
Resumo:
This paper documents the design, implementation and characterisation of a wireless sensor node (GENESI Node v1.0), applicable to long-term structural health monitoring. Presented is a three layer abstraction of the hardware platform; consisting of a Sensor Layer, a Main Layer and a Power Layer. Extended operational lifetime is one of the primary design goals, necessitating the inclusion of supplemental energy sources, energy awareness, and the implementation of optimal components (microcontroller(s), RF transceiver, etc.) to achieve lowest-possible power consumption, whilst ensuring that the functional requirements of the intended application area are satisfied. A novel Smart Power Unit has been developed; including intelligence, ambient available energy harvesting (EH), storage, electrochemical fuel cell integration, and recharging capability, which acts as the Power Layer for the node. The functional node has been prototyped, demonstrated and characterised in a variety of operational modes. It is demonstrable via simulation that, under normal operating conditions within a structural health monitoring application, the node may operate perpetually.
Resumo:
Wireless Inertial Measurement Units (WIMUs) combine motion sensing, processing & communications functionsin a single device. Data gathered using these sensors has the potential to be converted into high quality motion data. By outfitting a subject with multiple WIMUs full motion data can begathered. With a potential cost of ownership several orders of magnitude less than traditional camera based motion capture, WIMU systems have potential to be crucially important in supplementing or replacing traditional motion capture and opening up entirely new application areas and potential markets particularly in the rehabilitative, sports & at-home healthcarespaces. Currently WIMUs are underutilized in these areas. A major barrier to adoption is perceived complexity. Sample rates, sensor types & dynamic sensor ranges may need to be adjusted on multiple axes for each device depending on the scenario. As such we present an advanced WIMU in conjunction with a Smart WIMU system to simplify this aspect with 3 usage modes: Manual, Intelligent and Autonomous. Attendees will be able to compare the 3 different modes and see the effects of good andbad set-ups on the quality of data gathered in real time.
Resumo:
This paper provides a system description and preliminary results for an ongoing clinical study currently being carried out at the Mid-Western Regional Hospital, Nenagh, Ireland. The goal of the trial is to determine if wireless inertial measurement technology can be employed to identify elderly patients at risk of death or imminent clinical deterioration. The system measures cumulative movement and provides a score that will help provide a robust early warning to clinical staff of clinical deterioration. In addition the study examines some of the logistical barriers to the adoption of wearable wireless technology in front-line medical care.
Resumo:
This is a user manual for your electronic assistive technology environmental control system trial pack or in simple words – a few bits of technology that can let you control some household appliances. This information is intended for you, your family and carers.
Resumo:
Occupational therapists need to embrace the use of mainstream technology in their quest to ensure that therapy remains current and meaningful to their clients. Technology can be useful to improve both functional independence and occupational performance. This opinion piece introduces how occupational therapists can apply mainstream technologies, including information and communication technologies such as the internet, computer software, portable devices and computer games, in their everyday interventions.
Resumo:
Introduction: Electronic assistive technology (EAT) includes computers, environmental control systems and information technology systems and is widely considered to be an important part of present-day life. Method: Fifty-six Irish community occupational therapists completed a questionnaire on EAT. All surveyed were able to identify the benefits of EAT. Results: While respondents reported that they should be able to assess for and prescribe EATs, only a third (19) were able to do so, and half (28) had not been able to do so in the past. Community occupational therapists identified themselves as havinga role in a multidisciplinary team to assess for and prescribe EAT. Conclusion: Results suggest that it is important for occupational therapists to have up-to-date knowledge and training in assistive and computer technologies in order to respond to the occupational needs of clients.
Resumo:
An important component of this Ph.D. thesis was to determine the European consumers’ views on processed meats and bioactive compounds. Thus a survey gathered information form over 500 respondents and explored their perceptions on the healthiness and purchase-ability for both traditional and functional processed meats. This study found that the consumer was distrustful towards processed meat, especially high salt and fat content. Consumers were found to be very pro-bioactive compounds in yogurt style products but unsure of their feelings on the idea of them in meat based products, which is likely due to the lack of familiarity to these products. The work in this thesis also centred on the applied acceptable reduction of salt and fat in terms of consumer sensory analysis. The products chosen ranged in the degree of comminution, from a coarse beef patty to a more fine emulsion style breakfast sausage and frankfurter. A full factorial design was implemented which saw the production of twenty beef patties with varying concentrations of fat (30%, 40%, 50%, 60% w/w) and salt (0.5%, 0.75%, 1.0%, 1.25%, 1.5% w/w). Twenty eight sausage were also produced with varying concentrations of fat (22.5%, 27.5%, 32.5%, 37.5% w/w) and salt (0.8%, 1%, 1.2%, 1.4%, 1.6%, 2%, 2.4% w/w). Finally, twenty different frankfurters formulations were produced with varying concentrations of fat (10%, 15%, 20%, 25% w/w) and salt (1%, 1.5%, 2%, 2.5%, 3% w/w). From these products it was found that the most consumer acceptable beef patty was that containing 40% fat with a salt level of 1%. This is a 20% decrease in fat and a 50% decrease in salt levels when compared to commercial patty available in Ireland and the UK. For sausages, salt reduced products were rated by the consumers as paler in colour, more tender and with greater meat flavour than higher salt containing products. The sausages containing 1.4 % and 1.0 % salt were significantly (P<0.01) found to be more acceptable to consumers than other salt levels. Frankfurter salt levels below 1.5% were shown to have a negative effect on consumer acceptability, with 2.5% salt concentration being the most accepted (P<0.001) by consumers. Samples containing less fat and salt were found to be tougher, less juicy and had greater cooking losses. Thus salt perception is very important for consumer acceptability, but fat levels can be potentially reduced without significantly affecting overall acceptability. Overall it can be summarised that the consumer acceptability of salt and fat reduced processed meats depends very much on the product and generalisations cannot be assumed. The study of bio-actives in processed meat products found that the reduced salt/fat patties fortified with CoQ10 were rated as more acceptable than commercially available products for beef patties. The reduced fat and salt, as well as the CoQ10 fortified, sausages were found to compare quite well to their commercial counterparts for overall acceptability, whereas commercial frankfurters were found to be the more favoured in comparison to reduced fat and CoQ10 fortified Frankfurters.
Resumo:
The healthcare industry is beginning to appreciate the benefits which can be obtained from using Mobile Health Systems (MHS) at the point-of-care. As a result, healthcare organisations are investing heavily in mobile health initiatives with the expectation that users will employ the system to enhance performance. Despite widespread endorsement and support for the implementation of MHS, empirical evidence surrounding the benefits of MHS remains to be fully established. For MHS to be truly valuable, it is argued that the technological tool be infused within healthcare practitioners work practices and used to its full potential in post-adoptive scenarios. Yet, there is a paucity of research focusing on the infusion of MHS by healthcare practitioners. In order to address this gap in the literature, the objective of this study is to explore the determinants and outcomes of MHS infusion by healthcare practitioners. This research study adopts a post-positivist theory building approach to MHS infusion. Existing literature is utilised to develop a conceptual model by which the research objective is explored. Employing a mixed-method approach, this conceptual model is first advanced through a case study in the UK whereby propositions established from the literature are refined into testable hypotheses. The final phase of this research study involves the collection of empirical data from a Canadian hospital which supports the refined model and its associated hypotheses. The results from both phases of data collection are employed to develop a model of MHS infusion. The study contributes to IS theory and practice by: (1) developing a model with six determinants (Availability, MHS Self-Efficacy, Time-Criticality, Habit, Technology Trust, and Task Behaviour) and individual performance-related outcomes of MHS infusion (Effectiveness, Efficiency, and Learning), (2) examining undocumented determinants and relationships, (3) identifying prerequisite conditions that both healthcare practitioners and organisations can employ to assist with MHS infusion, (4) developing a taxonomy that provides conceptual refinement of IT infusion, and (5) informing healthcare organisations and vendors as to the performance of MHS in post-adoptive scenarios.
Resumo:
Structural Health Monitoring (SHM) is an integral part of infrastructure maintenance and management systems due to socio-economic, safety and security reasons. The behaviour of a structure under vibration depends on structure characteristics. The change of structure characteristics may suggest the change in system behaviour due to the presence of damage(s) within. Therefore the consistent, output signal guided, and system dependable markers would be convenient tool for the online monitoring, the maintenance, rehabilitation strategies, and optimized decision making policies as required by the engineers, owners, managers, and the users from both safety and serviceability aspects. SHM has a very significant advantage over traditional investigations where tangible and intangible costs of a very high degree are often incurred due to the disruption of service. Additionally, SHM through bridge-vehicle interaction opens up opportunities for continuous tracking of the condition of the structure. Research in this area is still in initial stage and is extremely promising. This PhD focuses on using bridge-vehicle interaction response for SHM of damaged or deteriorating bridges to monitor or assess them under operating conditions. In the present study, a number of damage detection markers have been investigated and proposed in order to identify the existence, location, and the extent of an open crack in the structure. The theoretical and experimental investigation has been conducted on Single Degree of Freedom linear system, simply supported beams. The novel Delay Vector Variance (DVV) methodology has been employed for characterization of structural behaviour by time-domain response analysis. Also, the analysis of responses of actual bridges using DVV method has been for the first time employed for this kind of investigation.
Resumo:
The aim of this thesis was to identify selected potential probiotic characteristics of Bifidobacterium longum strains isolated from human sources, and to examine these characteristics in detail using genomic and phenotypic techniques. One strain in particular Bifidobacterium longum DPC 6315 was the main focus of the thesis and this strain was used in both the manufacture of yoghurt and an animal study. In total, 38 B. longum strains, obtained from infants and adults, were assessed in vitro for the selected probiotic traits using a combined phenotypic and molecular approach. Differentiation of the 38 strains using amplified ribosomal DNA restriction analysis (ARDRA) into subspecies indicated that of the 38 bifidobacterial strains tested, 34 were designated B. longum subsp. longum and four B. longum subsp. infantis.