5 resultados para Panoramic projections. Virtual Environments. Navigation in 3D environments. Virtual Reality

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One problem in most three-dimensional (3D) scalar data visualization techniques is that they often overlook to depict uncertainty that comes with the 3D scalar data and thus fail to faithfully present the 3D scalar data and have risks which may mislead users’ interpretations, conclusions or even decisions. Therefore this thesis focuses on the study of uncertainty visualization in 3D scalar data and we seek to create better uncertainty visualization techniques, as well as to find out the advantages/disadvantages of those state-of-the-art uncertainty visualization techniques. To do this, we address three specific hypotheses: (1) the proposed Texture uncertainty visualization technique enables users to better identify scalar/error data, and provides reduced visual overload and more appropriate brightness than four state-of-the-art uncertainty visualization techniques, as demonstrated using a perceptual effectiveness user study. (2) The proposed Linked Views and Interactive Specification (LVIS) uncertainty visualization technique enables users to better search max/min scalar and error data than four state-of-the-art uncertainty visualization techniques, as demonstrated using a perceptual effectiveness user study. (3) The proposed Probabilistic Query uncertainty visualization technique, in comparison to traditional Direct Volume Rendering (DVR) methods, enables radiologists/physicians to better identify possible alternative renderings relevant to a diagnosis and the classification probabilities associated to the materials appeared on these renderings; this leads to improved decision support for diagnosis, as demonstrated in the domain of medical imaging. For each hypothesis, we test it by following/implementing a unified framework that consists of three main steps: the first main step is uncertainty data modeling, which clearly defines and generates certainty types of uncertainty associated to given 3D scalar data. The second main step is uncertainty visualization, which transforms the 3D scalar data and their associated uncertainty generated from the first main step into two-dimensional (2D) images for insight, interpretation or communication. The third main step is evaluation, which transforms the 2D images generated from the second main step into quantitative scores according to specific user tasks, and statistically analyzes the scores. As a result, the quality of each uncertainty visualization technique is determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semiconductor chip packaging has evolved from single chip packaging to 3D heterogeneous system integration using multichip stacking in a single module. One of the key challenges in 3D integration is the high density interconnects that need to be formed between the chips with through-silicon-vias (TSVs) and inter-chip interconnects. Anisotropic Conductive Film (ACF) technology is one of the low-temperature, fine-pitch interconnect method, which has been considered as a potential replacement for solder interconnects in line with continuous scaling of the interconnects in the IC industry. However, the conventional ACF materials are facing challenges to accommodate the reduced pad and pitch size due to the micro-size particles and the particle agglomeration issue. A new interconnect material - Nanowire Anisotropic Conductive Film (NW-ACF), composed of high density copper nanowires of ~ 200 nm diameter and 10-30 µm length that are vertically distributed in a polymeric template, is developed in this work to tackle the constrains of the conventional ACFs and serves as an inter-chip interconnect solution for potential three-dimensional (3D) applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary objective is to investigate the main factors contributing to GMS expenditure on pharmaceutical prescribing and projecting this expenditure to 2026. This study is located in the area of pharmacoeconomic cost containment and projections literature. The thesis has five main aims: 1. To determine the main factors contributing to GMS expenditure on pharmaceutical prescribing. 2. To develop a model to project GMS prescribing expenditure in five year intervals to 2026, using 2006 Central Statistics Office (CSO) Census data and 2007 Health Service Executive{Primary Care Reimbursement Service (HSE{PCRS) sample data. 3. To develop a model to project GMS prescribing expenditure in five year intervals to 2026, using 2012 HSE{PCRS population data, incorporating cost containment measures, and 2011 CSO Census data. 4. To investigate the impact of demographic factors and the pharmacology of drugs (Anatomical Therapeutic Chemical (ATC)) on GMS expenditure. 5. To explore the consequences of GMS policy changes on prescribing expenditure and behaviour between 2008 and 2014. The thesis is centered around three published articles and is located between the end of a booming Irish economy in 2007, a recession from 2008{2013, to the beginning of a recovery in 2014. The literature identified a number of factors influencing pharmaceutical expenditure, including population growth, population aging, changes in drug utilisation and drug therapies, age, gender and location. The literature identified the methods previously used in predictive modelling and consequently, the Monte Carlo Simulation (MCS) model was used to simulate projected expenditures to 2026. Also, the literature guided the use of Ordinary Least Squares (OLS) regression in determining demographic and pharmacology factors influencing prescribing expenditure. The study commences against a backdrop of growing GMS prescribing costs, which has risen from e250 million in 1998 to over e1 billion by 2007. Using a sample 2007 HSE{PCRS prescribing data (n=192,000) and CSO population data from 2008, (Conway et al., 2014) estimated GMS prescribing expenditure could rise to e2 billion by2026. The cogency of these findings was impacted by the global economic crisis of 2008, which resulted in a sharp contraction in the Irish economy, mounting fiscal deficits resulting in Ireland's entry to a bailout programme. The sustainability of funding community drug schemes, such as the GMS, came under the spotlight of the EU, IMF, ECB (Trioka), who set stringent targets for reducing drug costs, as conditions of the bailout programme. Cost containment measures included: the introduction of income eligibility limits for GP visit cards and medical cards for those aged 70 and over, introduction of co{payments for prescription items, reductions in wholesale mark{up and pharmacy dispensing fees. Projections for GMS expenditure were reevaluated using 2012 HSE{PCRS prescribing population data and CSO population data based on Census 2011. Taking into account both cost containment measures and revised population predictions, GMS expenditure is estimated to increase by 64%, from e1.1 billion in 2016 to e1.8 billion by 2026, (ConwayLenihan and Woods, 2015). In the final paper, a cross{sectional study was carried out on HSE{PCRS population prescribing database (n=1.63 million claimants) to investigate the impact of demographic factors, and the pharmacology of the drugs, on GMS prescribing expenditure. Those aged over 75 (ẞ = 1:195) and cardiovascular prescribing (ẞ = 1:193) were the greatest contributors to annual GMS prescribing costs. Respiratory drugs (Montelukast) recorded the highest proportion and expenditure for GMS claimants under the age of 15. Drugs prescribed for the nervous system (Escitalopram, Olanzapine and Pregabalin) were highest for those between 16 and 64 years with cardiovascular drugs (Statins) were highest for those aged over 65. Females are more expensive than males and are prescribed more items across the four ATC groups, except among children under 11, (ConwayLenihan et al., 2016). This research indicates that growth in the proportion of the elderly claimants and associated levels of cardiovascular prescribing, particularly for statins, will present difficulties for Ireland in terms of cost containment. Whilst policies aimed at cost containment (co{payment charges, generic substitution, reference pricing, adjustments to GMS eligibility) can be used to curtail expenditure, health promotional programs and educational interventions should be given equal emphasis. Also policies intended to affect physicians prescribing behaviour include guidelines, information (about price and less expensive alternatives) and feedback, and the use of budgetary restrictions could yield savings.