4 resultados para Outcomes of care

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims 1 To identify the 3D soft tissue volumetric and linear landmark changes following treatment with the Twin-Block Appliance TBA. 2 To estimate the TBA treatment outcome on the soft tissue facial profile volumetric and linear landmark changes from the Postured Wax Bite (PWB). 3 To identify if there is any association between certain soft tissue landmark variables and successful treatment outcome of the TBA as measured by the reduction in overjet. 4 To assess the effects of TBA treatment on facial expressions. Materials and Methods Forty-seven Caucasian subjects with Class II division 1 were recruited. 3D images captured of each subject, pre-treatment (T1), with the PWB (T2) and at the end of treatment (T3). Soft tissue volumetric and linear changes as well as the correlation between facial parameters and successful treatment were calculated. Results The mean soft tissue volumetric change from T1 to T3 was 22.24 ± 16.73 cm³. Soft tissue profile linear changes from T1-T3 for lower facial landmarks were 4-5 mm. From T1-T3, the mean soft tissue volumetric change of the total sample was 60% of the change produced by the PWB (T1 to T2). Correlations were weak for all 3D facial parameters and successful overjet reduction. Facial expression changes were only significant for the lower landmarks. Conclusions 1 TBA treatment, in growing subjects, increased the lower facial soft tissue volume and caused forward movement of the lower soft tissue facial profile landmarks.2 The PWB can be used to estimate the treatment outcome of the TBA on soft tissue profile changes.3 No association was found between soft tissue landmark variables and successful overjet reduction.4 TBA treatment had no effect on the upper facial landmarks for each facial expression but it changed the lower facial expressions significantly except for maximal smile in males.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Gatekeeper training for community facilitators, to identify and respond to those at risk of suicide, forms an important part of multi-level community-based suicide prevention programmes. Aims: This study examined the effects of gatekeeper training on attitudes, knowledge and confidence of police officers in dealing with persons at risk of suicide. Methods: A total of 828 police officers across three European regions participated in a 4-hour training programme which addressed the epidemiology of depression and suicidal behaviour, symptoms of depression, warning signs and risk factors associated with suicidal behaviour, motivating help-seeking behaviour, dealing with acute suicidal crisis and informing bereaved relatives. Participants completed internationally validated questionnaires assessing stigmatising attitudes, knowledge about depression and confidence in dealing with suicidal persons pre- and post-training. Results: There were significant differences among countries in terms of previous exposure to suicidal persons and extent of previous training. Post-training evaluation demonstrated significant improvements in stigmatising attitudes, knowledge and confidence in all three countries. Conclusion: The consistently positive effects of gatekeeper training of police officers across different regions support inclusion of this type of training as a fundamental part of multi-level community-based suicide prevention programmes and roll-out, nationally and internationally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The healthcare industry is beginning to appreciate the benefits which can be obtained from using Mobile Health Systems (MHS) at the point-of-care. As a result, healthcare organisations are investing heavily in mobile health initiatives with the expectation that users will employ the system to enhance performance. Despite widespread endorsement and support for the implementation of MHS, empirical evidence surrounding the benefits of MHS remains to be fully established. For MHS to be truly valuable, it is argued that the technological tool be infused within healthcare practitioners work practices and used to its full potential in post-adoptive scenarios. Yet, there is a paucity of research focusing on the infusion of MHS by healthcare practitioners. In order to address this gap in the literature, the objective of this study is to explore the determinants and outcomes of MHS infusion by healthcare practitioners. This research study adopts a post-positivist theory building approach to MHS infusion. Existing literature is utilised to develop a conceptual model by which the research objective is explored. Employing a mixed-method approach, this conceptual model is first advanced through a case study in the UK whereby propositions established from the literature are refined into testable hypotheses. The final phase of this research study involves the collection of empirical data from a Canadian hospital which supports the refined model and its associated hypotheses. The results from both phases of data collection are employed to develop a model of MHS infusion. The study contributes to IS theory and practice by: (1) developing a model with six determinants (Availability, MHS Self-Efficacy, Time-Criticality, Habit, Technology Trust, and Task Behaviour) and individual performance-related outcomes of MHS infusion (Effectiveness, Efficiency, and Learning), (2) examining undocumented determinants and relationships, (3) identifying prerequisite conditions that both healthcare practitioners and organisations can employ to assist with MHS infusion, (4) developing a taxonomy that provides conceptual refinement of IT infusion, and (5) informing healthcare organisations and vendors as to the performance of MHS in post-adoptive scenarios.