3 resultados para Nuclear saline water conversion plants.

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proactive risk management strategy seeks to prevent accidents from taking place and maintain the safety of a system. In this context, the task of identifying and disseminating early warning signs and signals is among the most important. The problem is that warning signs that are present before an accident takes place are often being overlooked and not picked up or identified as warning signs. If these warning signs were responded to, then an accident may be averted. Accidents occuring in the critical domain of a drinking water treatments works can have serious implications for the public health of consumers of the water supplied. Realising and comprehending early warning signs is a major challenge for the domain of systems safety and especially in the domain of a water treatment works. The approaches that are typically used to enhance the realisation, comprehension and dissemination of early warning signs in the water treatment domain in Ireland mainly involves the creation of accident scenarios, the use of monitoring data and procedures for the dissemination of warnings. While all of these approaches are all useful to inform the mental or process models of possible accident scenarios, nevertheless, accidents are still occurring in this domain. Therefore, a new approach to enhance the comprehension of and effective dissemination of early warning signs is required in order to improve safety and proactive risk management strategies. The contributions of this thesis is the provision of a set of attributes associated with the early warning sign concept that provides meaningful data on the early warning signs and allows recipients to better comprehend them. The values of these attributes were customised for application in the water treatment domain. This research proves that early warning signs at a water treatment works received with information on their attributes are comprehended and communicated more effectively and efficiently than the usual pragmatic approach and thereby improves the safety and proactive risk management strategies.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents an investigation on air compressibility in the air chamber and its effects on the power conversion of oscillating water column (OWC) devices. As it is well known that for practical OWC plants, their air chambers may be large enough for accommodating significant air compressibility, the “spring effect,” an effect that is frequently and simply regarded to store and release energy during the reciprocating process of a wave cycle. Its insight effects on the device’s performance and power conversion, however, have not been studied in detail. This research will investigate the phenomena with a special focus on the effects of air compressibility on wave energy conversion. Air compressibility itself is a complicated nonlinear process in nature, but it can be linearised for numerical simulations under certain assumptions for frequency domain analysis. In this research work, air compressibility in the OWC devices is first linearised and further coupled with the hydrodynamics of the OWC. It is able to show mathematically that in frequency-domain, air compressibility can increase the spring coefficients of both the water body motion and the device motion (if it is a floating device), and enhance the coupling effects between the water body and the structure. Corresponding to these changes, the OWC performance, the capture power, and the optimised Power Take-off (PTO) damping coefficient in the wave energy conversion can be all modified due to air compressibility. To validate the frequency-domain results and understand the problems better, the more accurate time-domain simulations with fewer assumptions have been used for comparison. It is shown that air compressibility may significantly change the dynamic responses and the capacity of converting wave energy of the OWC devices if the air chamber is very large.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper presents an investigation to the thermodynamics of the air flow in the air chamber for the oscillating water column wave energy converters, in which the oscillating water surface in the water column pressurizes or de-pressurises the air in the chamber. To study the thermodynamics and the compressibility of the air in the chamber, a method is developed in this research: the power take-off is replaced with an accepted semi-empirical relationship between the air flow rate and the oscillating water column chamber pressure, and the thermodynamic process is simplified as an isentropic process. This facilitates the use of a direct expression for the work done on the power take-off by the flowing air and the generation of a single differential equation that defines the thermodynamic process occurring inside the air chamber. Solving the differential equation, the chamber pressure can be obtained if the interior water surface motion is known or the chamber volume (thus the interior water surface motion) if the chamber pressure is known. As a result, the effects of the air compressibility can be studied. Examples given in the paper have shown the compressibility, and its effects on the power losses for large oscillating water column devices.