6 resultados para Network Management

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Existing Building/Energy Management Systems (BMS/EMS) fail to convey holistic performance to the building manager. A 20% reduction in energy consumption can be achieved by efficiently operated buildings compared with current practice. However, in the majority of buildings, occupant comfort and energy consumption analysis is primarily restricted by available sensor and meter data. Installation of a continuous monitoring process can significantly improve the building systems’ performance. We present WSN-BMDS, an IP-based wireless sensor network building monitoring and diagnostic system. The main focus of WSN-BMDS is to obtain much higher degree of information about the building operation then current BMSs are able to provide. Our system integrates a heterogeneous set of wireless sensor nodes with IEEE 802.11 backbone routers and the Global Sensor Network (GSN) web server. Sensing data is stored in a database at the back office via UDP protocol and can be access over the Internet using GSN. Through this demonstration, we show that WSN-BMDS provides accurate measurements of air-temperature, air-humidity, light, and energy consumption for particular rooms in our target building. Our interactive graphical user interface provides a user-friendly environment showing live network topology, monitor network statistics, and run-time management actions on the network. We also demonstrate actuation by changing the artificial light level in one of the rooms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this research we focus on the Tyndall 25mm and 10mm nodes energy-aware topology management to extend sensor network lifespan and optimise node power consumption. The two tiered Tyndall Heterogeneous Automated Wireless Sensors (THAWS) tool is used to quickly create and configure application-specific sensor networks. To this end, we propose to implement a distributed route discovery algorithm and a practical energy-aware reaction model on the 25mm nodes. Triggered by the energy-warning events, the miniaturised Tyndall 10mm data collector nodes adaptively and periodically change their association to 25mm base station nodes, while 25mm nodes also change the inter-connections between themselves, which results in reconfiguration of the 25mm nodes tier topology. The distributed routing protocol uses combined weight functions to balance the sensor network traffic. A system level simulation is used to quantify the benefit of the route management framework when compared to other state of the art approaches in terms of the system power-saving.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Buildings consume 40% of Ireland's total annual energy translating to 3.5 billion (2004). The EPBD directive (effective January 2003) places an onus on all member states to rate the energy performance of all buildings in excess of 50m2. Energy and environmental performance management systems for residential buildings do not exist and consist of an ad-hoc integration of wired building management systems and Monitoring & Targeting systems for non-residential buildings. These systems are unsophisticated and do not easily lend themselves to cost effective retrofit or integration with other enterprise management systems. It is commonly agreed that a 15-40% reduction of building energy consumption is achievable by efficiently operating buildings when compared with typical practice. Existing research has identified that the level of information available to Building Managers with existing Building Management Systems and Environmental Monitoring Systems (BMS/EMS) is insufficient to perform the required performance based building assessment. The cost of installing additional sensors and meters is extremely high, primarily due to the estimated cost of wiring and the needed labour. From this perspective wireless sensor technology provides the capability to provide reliable sensor data at the required temporal and spatial granularity associated with building energy management. In this paper, a wireless sensor network mote hardware design and implementation is presented for a building energy management application. Appropriate sensors were selected and interfaced with the developed system based on user requirements to meet both the building monitoring and metering requirements. Beside the sensing capability, actuation and interfacing to external meters/sensors are provided to perform different management control and data recording tasks associated with minimisation of energy consumption in the built environment and the development of appropriate Building information models(BIM)to enable the design and development of energy efficient spaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Comfort is, in essence, satisfaction with the environment, and with respect to the indoor environment it is primarily satisfaction with the thermal conditions and air quality. Improving comfort has social, health and economic benefits, and is more financially significant than any other building cost. Despite this, comfort is not strictly managed throughout the building lifecycle. This is mainly due to the lack of an appropriate system to adequately manage comfort knowledge through the construction process into operation. Previous proposals to improve knowledge management have not been successfully adopted by the construction industry. To address this, the BabySteps approach was devised. BabySteps is an approach, proposed by this research, which states that for an innovation to be adopted into the industry it must be implementable through a number of small changes. This research proposes that improving the management of comfort knowledge will improve comfort. ComMet is a new methodology proposed by this research that manages comfort knowledge. It enables comfort knowledge to be captured, stored and accessed throughout the building life-cycle and so allowing it to be re-used in future stages of the building project and in future projects. It does this using the following: Comfort Performances – These are simplified numerical representations of the comfort of the indoor environment. Comfort Performances quantify the comfort at each stage of the building life-cycle using standard comfort metrics. Comfort Ratings - These are a means of classifying the comfort conditions of the indoor environment according to an appropriate standard. Comfort Ratings are generated by comparing different Comfort Performances. Comfort Ratings provide additional information relating to the comfort conditions of the indoor environment, which is not readily determined from the individual Comfort Performances. Comfort History – This is a continuous descriptive record of the comfort throughout the project, with a focus on documenting the items and activities, proposed and implemented, which could potentially affect comfort. Each aspect of the Comfort History is linked to the relevant comfort entity it references. These three components create a comprehensive record of the comfort throughout the building lifecycle. They are then stored and made available in a common format in a central location which allows them to be re-used ad infinitum. The LCMS System was developed to implement the ComMet methodology. It uses current and emerging technologies to capture, store and allow easy access to comfort knowledge as specified by ComMet. LCMS is an IT system that is a combination of the following six components: Building Standards; Modelling & Simulation; Physical Measurement through the specially developed Egg-Whisk (Wireless Sensor) Network; Data Manipulation; Information Recording; Knowledge Storage and Access.Results from a test case application of the LCMS system - an existing office room at a research facility - highlighted that while some aspects of comfort were being maintained, the building’s environment was not in compliance with the acceptable levels as stipulated by the relevant building standards. The implementation of ComMet, through LCMS, demonstrates how comfort, typically only considered during early design, can be measured and managed appropriately through systematic application of the methodology as means of ensuring a healthy internal environment in the building.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Compared to existing literature on childhood attention deficit hyperactivity disorder (ADHD), little published adult data are available, particularly outside of the United States. Using General Practitioner (GP) questionnaires from the United Kingdom, this study aimed to examine a number of issues related to ADHD in adults, across three cohorts of patients, adults who received ADHD drug treatment in childhood/adolescence but stopped prior to adulthood; adults who received ADHD drug treatment in childhood/adolescence and continued treatment into adulthood and adults who started ADHD drug treatment in adulthood.Methods: Patients with a diagnosis of ADHD and prescribed methylphenidate, dexamfetamine or atomoxetine were identified using data from The Health Improvement Network (THIN). Dates when these drugs started and stopped were used to classify patients into the three cohorts. From each cohort, 50 patients were randomly selected and questionnaires were sent via THIN to their GPs.GPs returned completed questionnaires to THIN who forwarded anonymised copies to the researchers. Datasets were analysed using descriptive statistics.Results: Overall response rate was 89% (133/150). GPs stated that in 19 cases, the patient did not meet the criteria of that group; the number of valid questionnaires returned was 114 (76%). The following broad trends were observed: 1) GPs were not aware of the reason for treatment cessation in 43% of cases, 2) patient choice was the most common reason for discontinuation (56%), 3) 7% of patients who stopped pharmacological treatment subsequently reported experiencing ADHD symptoms, 4) 58% of patients who started pharmacological treatment for ADHD in adulthood received pharmacological treatment for other mental health conditions prior to the ADHD being diagnosed.Conclusion: This study presents some key findings relating to ADHD; GPs were often not aware of the reason for patients stopping ADHD treatment in childhood or adolescence. Patient choice was identified as the most common reason for treatment cessation. For patients who started pharmacological treatment in adulthood, many patients received pharmacological treatment for comorbidities before a diagnosis of ADHD was made.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alasdair MacIntyre’s distinction between institutions and practices helps illuminate how powerful institutional forces frame and constrain the practice of organizational research as well as the output and positioning of scholarly journals like Organization. Yet his conceptual frame is limited, not least because it is unclear whether the activity of managing is, or is not, a practice. This article builds on MacIntyre’s ideas by incorporating Aristotle’s concepts of poíēsis, praxis, téchnē and phrónēsis. Rather than ask, following MacIntyre, whether management is a practice, this wider network of concepts provides a richer frame for understanding the nature of managing and the appropriate role for academia. The article outlines a phronetic paradigm for organizational inquiry, and concludes by briefly examining the implications of such a paradigm for research and learning.