4 resultados para Nanostructured lipid carriers

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructured materials are central to the evolution of future electronics and information technologies. Ferroelectrics have already been established as a dominant branch in the electronics sector because of their diverse application range such as ferroelectric memories, ferroelectric tunnel junctions, etc. The on-going dimensional downscaling of materials to allow packing of increased numbers of components onto integrated circuits provides the momentum for the evolution of nanostructured ferroelectric materials and devices. Nanoscaling of ferroelectric materials can result in a modification of their functionality, such as phase transition temperature or Curie temperature (TC), domain dynamics, dielectric constant, coercive field, spontaneous polarisation and piezoelectric response. Furthermore, nanoscaling can be used to form high density arrays of monodomain ferroelectric nanostructures, which is desirable for the miniaturisation of memory devices. This thesis details the use of various types of nanostructuring approaches to fabricate arrays of ferroelectric nanostructures, particularly non-oxide based systems. The introductory chapter reviews some exemplary research breakthroughs in the synthesis, characterisation and applications of nanoscale ferroelectric materials over the last decade, with priority given to novel synthetic strategies. Chapter 2 provides an overview of the experimental methods and characterisation tools used to produce and probe the properties of nanostructured antimony sulphide (Sb2S3), antimony sulpho iodide (SbSI) and lead titanate zirconate (PZT). In particular, Chapter 2 details the general principles of piezoresponse microscopy (PFM). Chapter 3 highlights the fabrication of arrays of Sb2S3 nanowires with variable diameters using newly developed solventless template-based approach. A detailed account of domain imaging and polarisation switching of these nanowire arrays is also provided. Chapter 4 details the preparation of vertically aligned arrays of SbSI nanorods and nanowires using a surface-roughness assisted vapour-phase deposition method. The qualitative and quantitative nanoscale ferroelectric properties of these nanostructures are also discussed. Chapter 5 highlights the fabrication of highly ordered arrays of PZT nanodots using block copolymer self-assembled templates and their ferroelectric characterisation using PFM. Chapter 6 summarises the conclusions drawn from the results reported in chapters 3, 4 and 5 and the future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Li-ion battery has for several years been at the forefront of powering an ever-increasing number of modem consumer electronic devices such as laptops, tablet PCs, cell phones, portable music players etc., while in more recent times, has also been sought to power a range of emerging electric and hybrid-electric vehicle classes. Given their extreme popularity, a number of features which define the performance of the Li-ion battery have become a target of improvement and have garnered tremendous research effort over the past two decades. Features such as battery capacity, voltage, lifetime, rate performance, together with important implications such as safety, environmental benignity and cost have all attracted attention. Although properties such as cell voltage and theoretical capacity are bound by the selection of electrode materials which constitute its interior, other performance makers of the Li-ion battery such as actual capacity, lifetime and rate performance may be improved by tailoring such materials with characteristics favourable to Li+ intercalation. One such tailoring route involves shrinking of the constituent electrode materials to that of the nanoscale, where the ultra-small diameters may bestow favourable Li+ intercalation properties while providing a necessary mechanical robustness during routine electrochemical operation. The work detailed in this thesis describes a range of synthetic routes taken in nanostructuring a selection of choice Li-ion positive electrode candidates, together with a review of their respective Li-ion performances. Chapter one of this thesis serves to highlight a number of key advancements which have been made and detailed in the literature over recent years pertaining to the use of nanostructured materials in Li-ion technology. Chapter two provides an overview of the experimental conditions and techniques employed in the synthesis and electrochemical characterisation of the as-prepared electrode materials constituting this doctoral thesis. Chapter three details the synthesis of small-diameter V2O5 and V2O5/TiO2 nanocomposite structures prepared by a novel carbon nanocage templating method using liquid precursors. Chapter four details a hydrothermal synthesis and characterisation of nanostructured β-LiVOPO4 powders together with an overview of their Li+ insertion properties while chapter five focuses on supercritical fluid synthesis as one technique in the tailoring of FeF2 and CoF2 powders having potentially appealing Li-ion 'conversion' properties. Finally, chapter six summarises the overall conclusions drawn from the results presented in this thesis, coupled with an indication of potential future work which may be explored upon the materials described in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Li-ion battery has for a number of years been a key factor that has enabled an ever increasing number of modern consumer devices, while in recent years has also been sought to power a range of emerging electric and hybrid electric vehicles. Due to their importance and popularity, a number of characteristics of Li-ion batteries have been subjected to intense work aimed at radical improvement. Although electrode material selection intrinsically defines characteristics like maximum capacity or voltage, engineering of the electrode structure may yield significant improvements to the lifetime performance of the battery, which would not be available if the material was used in its bulk form. The body of work presented in this thesis describes the relationship between the structure of electrochemically active materials and the course of the electrochemical processes occurring within the electrode. Chapter one describes the motivation behind the research presented herein. Chapter two serves to highlight a number of key advancements which have been made and detailed in the literature over recent years, pertaining to the use of nanostructured materials in Li-ion technology. Chapter three details methods and techniques applied in developing the body of work presented in this thesis. Chapter four details structural, molecular and electrochemical characteristics of tin oxide nanoparticle based electrodes, with particular emphasis on the relationship between the size distribution and the electrode performance. Chapter five presents findings of structural, electrochemical and optical study of indium oxide nanoparticles grown on silicon by molecular beam epitaxy. In chapter 6, tin oxide inverted opal electrodes are investigated for the conduct of the electrochemical performance of the electrodes under varying rate of change of potential. Chapter 7 presents the overall conclusions drawn from the results presented in this thesis, coupled with an indication of potential future work which may be explored further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis work covered the fabrication and characterisation of impedance sensors for biological applications aiming in particular to the cytotoxicity monitoring of cultured cells exposed to different kind of chemical compounds and drugs and to the identification of different types of biological tissue (fat, muscles, nerves) using a sensor fabricated on the tip of a commercially available needle during peripheral nerve block procedures. Gold impedance electrodes have been successfully fabricated for impedance measurement on cells cultured on the electrode surface which was modified with the fabrication of gold nanopillars. These nanostructures have a height of 60nm or 100nm and they have highly ordered layout as they are fabricated through the e-beam technique. The fabrication of the threedimensional structures on the interdigitated electrodes was supposed to improve the sensitivity of the ECIS (electric cell-substrate impedance sensing) measurement while monitoring the cytotoxicity effects of two different drugs (Antrodia Camphorata extract and Nicotine) on three different cell lines (HeLa, A549 and BALBc 3T3) cultured on the impedance devices and change the morphology of the cells growing on the nanostructured electrodes. The fabrication of the nanostructures was achieved combining techniques like UV lithography, metal lift-off, evaporation and e-beam lithography techniques. The electrodes were packaged using a pressure sensitive, medical grade adhesive double-sided tape. The electrodes were then characterised with the aid of AFM and SEM imaging which confirmed the success of the fabrication processes showing the nanopillars fabricated with the right layout and dimensions figures. The introduction of nanopillars on the impedance electrodes, however, did not improve much the sensitivity of the assay with the exception of tests carried out with Nicotine. HeLa and A549 cells appeared to grow in a different way on the two surfaces, while no differences where noticed on the BALBc 3T3 cells. Impedance measurements obtained with the dead cells on the negative control electrodes or the test electrodes with the drugs can be compared to those done on the electrodes containing just media in the tested volume (as no cells are attached and cover the electrode surface). The impedance figures recorded using these electrodes were between 1.5kΩ and 2.5 kΩ, while the figures recorded on confluent cell layers range between 4kΩ and 5.5kΩ with peaks of almost 7 kΩ if there was more than one layer of cells growing on each other. There was then a very clear separation between the values of living cell compared to the dead ones which was almost 2.5 - 3kΩ. In this way it was very easy to determine whether the drugs affected the cells normal life cycle on not. However, little or no differences were noticed in the impedance analysis carried out on the two different kinds of electrodes using cultured cells. An increase of sensitivity was noticed only in a couple of experiments carried out on A549 cells growing on the nanostructured electrodes and exposed to different concentration of a solution containing Nicotine. More experiments to achieve a higher number of statistical evidences will be needed to prove these findings with an absolute confidence. The smart needle project aimed to reduce the limitations of the Electrical Nerve Stimulation (ENS) and the Ultra Sound Guided peripheral nerve block techniques giving the clinicians an additional tool for performing correctly the peripheral nerve block. Bioimpedance, as measured at the needle tip, provides additional information on needle tip location, thereby facilitating detection of intraneural needle placement. Using the needle as a precision instrument and guidance tool may provide additional information as to needle tip location and enhance safety in regional anaesthesia. In the time analysis, with the frequency fixed at 10kHz and the samples kept at 12°C, the approximate range for muscle bioimpedance was 203 – 616 Ω, the approximate bioimpedance range for fat was 5.02 - 17.8 kΩ and the approximate range for connective tissue was 790 Ω – 1.55 kΩ. While when the samples were heated at 37°C and measured again at 10kHz, the approximate bioimpedance range for muscle was 100-175Ω. The approximate bioimpedance range of fat was 627 Ω - 3.2 kΩ and the range for connective tissue was 221-540Ω. In the experiments done on the fresh slaughtered lamb carcass, replicating a scenario close to the real application, the impedance values recorded for fat were around 17 kΩ, for muscle and lean tissue around 1.3 kΩ while the nervous structures had an impedance value of 2.9 kΩ. With the data collected during this research, it was possible to conclude that measurements of bioimpedance at the needle tip location can give valuable information to the clinicians performing a peripheral nerve block procedure as the separation (in terms of impedance figures) was very marked between the different type of tissues. It is then feasible to use an impedance electrode fabricated on the needle tip to differentiate several tissues from the nerve tissue. Currently, several different methods are being studied to fabricate an impedance electrode on the surface of a commercially available needle used for the peripheral nerve block procedure.