3 resultados para Homogeneous CNT coatings
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
A novel deposition process named CoBlastTM, based on grit blasting technology, has been used to deposit hydroxyapatite (HA) onto titanium (Ti) metal using a dopant/abrasive regime. The various powders (HA powder, apatitic abrasives) and the treated substrates were characterised for chemical composition, coating coverage, crystallinity and topography including surface roughness. The surface roughness of the HA surfaces could be altered using apatitic abrasives of different particle sizes. Compared to the standard plasma spraying process, the CoBlast surface produced excellent coating adhesion, lower dissolution, higher levels of mechanical and chemical stability in stimulated body fluid (SBF). Enhanced viability of osteoblastic cells was also observed on the CoBlast HA surfaces compared to the microblast and untreated Ti as well as the plasma HA coating. CoBlast offers an alternative to the traditional methods of coating HA implants with added versatility. Apatites substituted with antimicrobial metals can also be deposited to add functionality to HA coatings without cytotoxicty. The potential use of these coatings as an infection preventing strategy for application on hard tissue implants was assessed in vitro and also in vivo. Surface physicochemical properties and morphology were determined in addition to surface cytocompatibility assessments using a MG-63 osteoblast cell line. The antibacterial potential of the immobilised metal ion on the surface and the eluted ion to a lesser extent, contributed to the anticolonising behaviour of the surfaces against a standard bacteria strain (S. aureus) as well as a number of clinically relevant strains (MRSA, MSSA and S. epidermis). The results revealed that the surfaces coated with silver substituted apatites (AgA) outperformed the other apatites examined (apatites loaded with Zn, Sr and both Ag and Sr ions). Assessment of bacterial adherence on coated K-wires following subcutaneous implantation in a nude mouse infection model (S. aureus) for two days demonstrated that the 12% wt surface outperformed the 5% wt AgA coating. Lower inflammatory responses were activated with the insertion of the Ag loaded K-wires with a localised infection at the implantation site noted over the two day study period. These results indicated that the AgA coating on the surface of orthopaedic implants demonstrate good biocompatibility whilst inhibiting bacterial adhesion and colonising of the implant surface.
Resumo:
The aetiological agent of chronic hepatitis C is the hepatitis C virus. The hepatitis C virus is spread by parenteral transmission of body fluids, primarily blood or blood products. In 1989, after more than a decade of research, HCV was isolated and characterised. The hepatitis C viral genome is a positive-sense, single-stranded RNA molecule approximately 9.4 kb in length, which encodes a polyprotein of about 3100 amino acids. There are 6 main genotypes of HCV, each further stratified by subtype. In 1994, a cohort of women was identified in Ireland as having been iatrogenically exposed to the hepatitis C virus. The women were all young and exposed as a consequence of the receipt of HCV 1b contaminated anti-D immunoglobulin. The source of the infection was identified as an acutely infected female. As part of a voluntary serological screening programme involving 62,667 people, 704 individuals were identified as seropositive for exposure to the hepatitis C virus; 55.4% were found to be positive for the viral genome 17 years after exposure. Of these women 98% had evidence of inflammation, but suprisingly, a remarkable 49% showed no evidence of fibrosis. Clinicopathology and virological analysis has identified associations between viral load and the histological activity index for inflammation, and, between inflammation and levels of the liver enzyme alanine aminotransferase. Infection at a younger age appears to protect individuals from progression to advanced liver disease. Molecular analyses of host immunogenetic elements shows that particular class II human leukocyte associated antigen alleles are associated with clearance of the hepatitis C virus. Additional class II alleles have been identified that are associated with stable viraemia over an extended period of patient follow-up. Although, investigation of large untreated homogeneous cohorts is likely to become more difficult, as the efficacy of anti-viral therapy improves, further investigation of host and viral factors that influence disease progression will help provide an evidence based approach were realistic expectations regarding patient prognosis can be ascertained.
Resumo:
TiSiC-Cr coatings, with Cr and Si as additional elements, were deposited on Si, C 45 and 316 L steel substrates via cathodic arc evaporation. Two series of coatings with thicknesses in the range of 3.6–3.9 μm were produced, using either CH4 or C2H2 as carbon containing gas. For each series, different coatings were prepared by varying the carbon rich gas flow rate between 90 and 130 sccm, while maintaining constant cathode currents (110 and 100 A at TiSi and Cr cathodes, respectively), substrate bias (–200 V) and substrate temperature (∼320 °C). The coatings were analyzed for their mechanical characteristics (hardness, adhesion) and tribological performance (friction, wear), along with their elemental and phase composition, chemical bonds, crystalline structure and cross-sectional morphology. The coatings were found to be formed with nano-scale composite structures consisting of carbide crystallites (grain size of 3.1–8.2 nm) and amorphous hydrogenated carbon. The experimental results showed significant differences between the two coating series, where the films formed from C2H2 exhibited markedly superior characteristics in terms of microstructure, morphology, hardness, friction behaviour and wear resistance. For the coatings prepared using CH4, the measured values of crystallite size, hardness, friction coefficient and wear rate were in the ranges of 7.2–8.2 nm, 26–30 GPa, 0.3–0.4 and 2.1–4.8 × 10−6 mm3 N−1 m−1, respectively, while for the coatings grown in C2H2, the values of these characteristics were found to be in the ranges of 3.1–3.7 nm, 41–45 GPa, 0.1–0.2 and 1.4–3.0 × 10−6 mm3 N−1 m−1, respectively. Among the investigated coatings, the one produced using C2H2 at the highest flow rate (130 sccm) exhibited the highest hardness (45.1 GPa), the lowest friction coefficient (0.10) and the best wear resistance (wear rate of 1.4 × 10−6 mm3 N−1 m−1).