5 resultados para High heating rates

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This dissertation proposes and demonstrates novel smart modules to solve challenging problems in the areas of imaging, communications, and displays. The smartness of the modules is due to their ability to be able to adapt to changes in operating environment and application using programmable devices, specifically, electronically variable focus lenses (ECVFLs) and digital micromirror devices (DMD). The proposed modules include imagers for laser characterization and general purpose imaging which smartly adapt to changes in irradiance, optical wireless communication systems which can adapt to the number of users and to changes in link length, and a smart laser projection display that smartly adjust the pixel size to achieve a high resolution projected image at each screen distance. The first part of the dissertation starts with the proposal of using an ECVFL to create a novel multimode laser beam characterizer for coherent light. This laser beam characterizer uses the ECVFL and a DMD so that no mechanical motion of optical components along the optical axis is required. This reduces the mechanical motion overhead that traditional laser beam characterizers have, making this laser beam characterizer more accurate and reliable. The smart laser beam characterizer is able to account for irradiance fluctuations in the source. Using image processing, the important parameters that describe multimode laser beam propagation have been successfully extracted for a multi-mode laser test source. Specifically, the laser beam analysis parameters measured are the M2 parameter, w0 the minimum beam waist, and zR the Rayleigh range. Next a general purpose incoherent light imager that has a high dynamic range (>100 dB) and automatically adjusts for variations in irradiance in the scene is proposed. Then a data efficient image sensor is demonstrated. The idea of this smart image sensor is to reduce the bandwidth needed for transmitting data from the sensor by only sending the information which is required for the specific application while discarding the unnecessary data. In this case, the imager demonstrated sends only information regarding the boundaries of objects in the image so that after transmission to a remote image viewing location, these boundaries can be used to map out objects in the original image. The second part of the dissertation proposes and demonstrates smart optical communications systems using ECVFLs. This starts with the proposal and demonstration of a zero propagation loss optical wireless link using visible light with experiments covering a 1 to 4 m range. By adjusting the focal length of the ECVFLs for this directed line-of-sight link (LOS) the laser beam propagation parameters are adjusted such that the maximum amount of transmitted optical power is captured by the receiver for each link length. This power budget saving enables a longer achievable link range, a better SNR/BER, or higher power efficiency since more received power means the transmitted power can be reduced. Afterwards, a smart dual mode optical wireless link is proposed and demonstrated using a laser and LED coupled to the ECVFL to provide for the first time features of high bandwidths and wide beam coverage. This optical wireless link combines the capabilities of smart directed LOS link from the previous section with a diffuse optical wireless link, thus achieving high data rates and robustness to blocking. The proposed smart system can switch from LOS mode to Diffuse mode when blocking occurs or operate in both modes simultaneously to accommodate multiple users and operate a high speed link if one of the users requires extra bandwidth. The last part of this section presents the design of fibre optic and free-space optical switches which use ECVFLs to deflect the beams to achieve switching operation. These switching modules can be used in the proposed optical wireless indoor network. The final section of the thesis presents a novel smart laser scanning display. The ECVFL is used to create the smallest beam spot size possible for the system designed at the distance of the screen. The smart laser scanning display increases the spatial resoluti on of the display for any given distance. A basic smart display operation has been tested for red light and a 4X improvement in pixel resolution for the image has been demonstrated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mode-locked semiconductor lasers are compact pulsed sources with ultra-narrow pulse widths and high repetition-rates. In order to use these sources in real applications, their performance needs to be optimised in several aspects, usually by external control. We experimentally investigate the behaviour of recently-developed quantum-dash mode-locked lasers (QDMLLs) emitting at 1.55 μm under external optical injection. Single-section and two-section lasers with different repetition frequencies and active-region structures are studied. Particularly, we are interested in a regime which the laser remains mode-locked and the individual modes are simultaneously phase-locked to the external laser. Injection-locked self-mode-locked lasers demonstrate tunable microwave generation at first or second harmonic of the free-running repetition frequency with sub-MHz RF linewidth. For two-section mode-locked lasers, using dual-mode optical injection (injection of two coherent CW lines), narrowing the RF linewidth close to that of the electrical source, narrowing the optical linewidths and reduction in the time-bandwidth product is achieved. Under optimised bias conditions of the slave laser, a repetition frequency tuning ratio >2% is achieved, a record for a monolithic semiconductor mode-locked laser. In addition, we demonstrate a novel all-optical stabilisation technique for mode-locked semiconductor lasers by combination of CW optical injection and optical feedback to simultaneously improve the time-bandwidth product and timing-jitter of the laser. This scheme does not need an RF source and no optical to electrical conversion is required and thus is ideal for photonic integration. Finally, an application of injection-locked mode-locked lasers is introduced in a multichannel phase-sensitive amplifier (PSA). We show that with dual-mode injection-locking, simultaneous phase-synchronisation of two channels to local pump sources is realised through one injection-locking stage. An experimental proof of concept is demonstrated for two 10 Gbps phase-encoded (DPSK) channels showing more than 7 dB phase-sensitive gain and less than 1 dB penalty of the receiver sensitivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Integrated nanowire electrodes that permit direct, sensitive and rapid electrochemical based detection of chemical and biological species are a powerful emerging class of sensor devices. As critical dimensions of the electrodes enter the nanoscale, radial analyte diffusion profiles to the electrode dominate with a corresponding enhancement in mass transport, steady-state sigmoidal voltammograms, low depletion of target molecules and faster analysis. To optimise these sensors it is necessary to fully understand the factors that influence performance limits including: electrode geometry, electrode dimensions, electrode separation distances (within nanowire arrays) and diffusional mass transport. Therefore, in this thesis, theoretical simulations of analyte diffusion occurring at a variety of electrode designs were undertaken using Comsol Multiphysics®. Sensor devices were fabricated and corresponding experiments were performed to challenge simulation results. Two approaches for the fabrication and integration of metal nanowire electrodes are presented: Template Electrodeposition and Electron-Beam Lithography. These approaches allow for the fabrication of nanowires which may be subsequently integrated at silicon chip substrates to form fully functional electrochemical devices. Simulated and experimental results were found to be in excellent agreement validating the simulation model. The electrochemical characteristics exhibited by nanowire electrodes fabricated by electronbeam lithography were directly compared against electrochemical performance of a commercial ultra-microdisc electrode. Steady-state cyclic voltammograms in ferrocenemonocarboxylic acid at single ultra-microdisc electrodes were observed at low to medium scan rates (≤ 500 mV.s-1). At nanowires, steady-state responses were observed at ultra-high scan rates (up to 50,000 mV.s-1), thus allowing for much faster analysis (20 ms). Approaches for elucidating faradaic signal without the requirement for background subtraction were also developed. Furthermore, diffusional process occurring at arrays with increasing inter-electrode distance and increasing number of nanowires were explored. Diffusion profiles existing at nanowire arrays were simulated with Comsol Multiphysics®. A range of scan rates were modelled, and experiments were undertaken at 5,000 mV.s-1 since this allows rapid data capture required for, e.g., biomedical, environmental and pharmaceutical diagnostic applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The treatment of oral cancer is complex and lengthy. Curative treatment implies a combination of surgery, radiotherapy and chemotherapy. The main goal of treatment is to guarantee long-term tumour free survival with as little functional and cosmetic damage. Despite progress in developing these strategies, cancers of the oral cavity continue to have high mortality rates that have not improved dramatically over the past ten years. Aim: The aim of this study was to uniquely explore the dynamic changes in the physical, psychological, social and existential experiences of newly diagnosed patients with oral cancer at two points across their cancer illness trajectory i.e. at the time of diagnosis and at the end of treatment. Methodology: A qualitative prospective longitudinal design was employed. Non-probability purposive sampling allowed the recruitment of 10 participants. The principal data collection method used was a digital audio taped semi-structured interview along with drawings produced by the participants. Analysis: Data was analysed using latent content analyses. Summary: Three ‘dynamic’ themes, physical, psychosocial and existential experiences were revealed that interact and influence each other in a complex and compound whole. These experiences are present at different degrees and throughout the entire trajectory of care. Patients have a number of specific concerns and challenges that cannot be compartmentalised into unitary or discrete aspects of their daily lives. Conclusion & Implications: An understanding of the patient’s experience of their illness at all stages of the disease trajectory, is essential to inform service providers’ decision making if the delivery of care is to be client centred. Dynamic and fluctuating changes in the patient’s personal experience of the cancer journey require dynamic, energetic and timely input from health care professionals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: On-going surveillance of behaviours during pregnancy is an important but overlooked population health activity that is particularly lacking in Ireland. Few, if any, nationally representative estimates of most maternal behaviours and experiences are available. While on-going surveillance of maternal behaviours has not been a priority thus far in European countries including Ireland, on-going surveillance was identified as a key priority in the United States (US) during the 1980’s when the Pregnancy Risk Assessment Monitoring System (PRAMS), was established. Today, PRAMS is the only surveillance programme of maternal behaviours and experiences world-wide. Although on-going prevalence estimates are required in Ireland, studies which examine the offspring health effects of maternal behaviours are also required, since various questions regarding maternal exposures and their offspring health effects remain unanswered. Gestational alcohol consumption is one such important maternal exposure which is common in pregnancy, though its offspring health effects are unclear, particularly at lower or moderate levels. Thus, guidelines internationally have not reached consensus on safe alcohol recommendations for pregnant women. The aims of this thesis are to implement the PRAMS in Ireland (PRAMS Ireland), to describe the prevalence of health behaviours around the time of pregnancy in Ireland and to examine the effect of health behaviours on pregnancy and child outcomes (specifically the relationship between alcohol use during pregnancy and infant and child growth). Structure: In Chapter 1, a brief background and rationale for the work, as well as the thesis aims and objective is provided. A detailed description of the design and implementation of PRAMS Ireland is described in Chapter 2. Chapter 3 and Chapter 4 describe the methodological results of the implementation of the PRAMS Ireland pilot study and PRAMS Ireland main study. In Chapter 5, a comparison of alcohol prevalence in two Irish studies (PRAMS Ireland and Growing up in Ireland (GUI)) and one multi-centre prospective cohort study, Screening for Pregnancy Endpoints (SCOPE) Study is detailed. Chapter 6 describes findings on adherence to National Clinical Guidelines on health behaviours and nutrition around the time of pregnancy in PRAMS Ireland. Findings on exposure to alcohol use in pregnancy and infant growth outcomes are described in Chapter 7 and Chapter 8. The results of analysis conducted to examine the impact of gestational alcohol use on offspring growth trajectories to age ten are described in Chapter 9. Finally, a discussion of the findings, strengths and limitations of the thesis, direction for future research, policy, practice and public health implications are discussed in Chapter 10.Results: Implementation of PRAMS: PRAMS may be an effective system for the surveillance of health behaviours around the time of pregnancy in the Irish context. PRAMS Ireland had high response rates (67% and 61% response rates in the pilot and main study respectively), high item completion rates and valid prevalence estimates for many health behaviours. Examining prevalence of health behaviours: We found high levels of alcohol consumption before and during pregnancy, poor adherence to healthy diets and high levels of smoking before and during pregnancy among women in Ireland. Socially disadvantaged women had higher rates of deleterious health behaviours before pregnancy, although women with the most deleterious behaviour profiles before pregnancy appeared to experience the greatest gain in protective health behaviours during pregnancy. The impact of alcohol use on infant and offspring growth: We found that low and moderate levels of alcohol use did not impact on birth outcomes or offspring growth whereas heavy alcohol consumption resulted in reduced birth length and birth weight; however, this finding was not consistently observed across all studies. Selection, reporting and confounding biases which are common in observational research could be masking harmful effects. Conclusion: PRAMS is a valid and feasible method of surveillance of health behaviours around the time of pregnancy in Ireland. A surveillance program of maternal behaviours and experiences is immediately warranted due to high levels of deleterious health behaviours around the time of pregnancy in Ireland. Although our results do not indicate any evidence of harm, given the quality of evidence available, abstinence and advice of abstinence from alcohol may be the most prudent choice for patients and healthcare professionals respectively. Further studies of the effects of gestational alcohol use are required; particularly those which can reduce selection bias, reporting bias and confounding.