3 resultados para Guidance dimensions

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of police accountability is not susceptible to a universal or concise definition. In the context of this thesis it is treated as embracing two fundamental components. First, it entails an arrangement whereby an individual, a minority and the whole community have the opportunity to participate meaningfully in the formulation of the principles and policies governing police operations. Second, it presupposes that those who have suffered as victims of unacceptable police behaviour should have an effective remedy. These ingredients, however, cannot operate in a vacuum. They must find an accommodation with the equally vital requirement that the burden of accountability should not be so demanding that the delivery of an effective police service is fatally impaired. While much of the current debate on police accountability in Britain and the USA revolves around the issue of where the balance should be struck in this accommodation, Ireland lacks the very foundation for such a debate as it suffers from a serious deficit in research and writing on police generally. This thesis aims to fill that gap by laying the foundations for an informed debate on police accountability and related aspects of police in Ireland. Broadly speaking the thesis contains three major interrelated components. The first is concerned with the concept of police in Ireland and the legal, constitutional and political context in which it operates. This reveals that although the Garda Siochana is established as a national force the legal prescriptions concerning its role and governance are very vague. Although a similar legislative format in Britain, and elsewhere, have been interpreted as conferring operational autonomy on the police it has not stopped successive Irish governments from exercising close control over the police. The second component analyses the structure and operation of the traditional police accountability mechanisms in Ireland; namely the law and the democratic process. It concludes that some basic aspects of the peculiar legal, constitutional and political structures of policing seriously undermine their capacity to deliver effective police accountability. In the case of the law, for example, the status of, and the broad discretion vested in, each individual member of the force ensure that the traditional legal actions cannot always provide redress where individuals or collective groups feel victimised. In the case of the democratic process the integration of the police into the excessively centralised system of executive government, coupled with the refusal of the Minister for Justice to accept responsibility for operational matters, project a barrier between the police and their accountability to the public. The third component details proposals on how the current structures of police accountability in Ireland can be strengthened without interfering with the fundamentals of the law, the democratic process or the legal and constitutional status of the police. The key elements in these proposals are the establishment of an independent administrative procedure for handling citizen complaints against the police and the establishment of a network of local police-community liaison councils throughout the country coupled with a centralised parliamentary committee on the police. While these proposals are analysed from the perspective of maximising the degree of police accountability to the public they also take into account the need to ensure that the police capacity to deliver an effective police service is not unduly impaired as a result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The issue, with international and national overtones, of direct relevance to the present study, relates to the shaping of beginning teachers’ identities in the workplace. As the shift from an initial teacher education programme into initial practice in schools is a period of identity change worthy of investigation, this study focuses on the transformative search by nine beginning primary teachers for their teaching identities, throughout the course of their initial year of occupational experience, post-graduation. The nine beginning teacher participants work in a variety of primary school settings, thus strengthening the representativeness of the research cohort. Privileging ‘insider’ perspectives, the research goal is to understand the complexities of lived experience from the viewpoints of the participating informants. The shaping of identity is conceived of in dimensional terms. Accordingly, a framework composed of three dimensions of beginning teacher experience is devised, namely: contextual; emotional; temporo-spatial. Data collection and analysis is informed by principles derived from sociocultural theories; activity theory; figured worlds theory; and, dialogical self theory. Individual, face-to-face semi-structured interviews, and the maintenance of solicited digital diaries, are the principal methods of data collection employed. The use of a dimensional model fragments the integrated learning experiences of beginning teachers into constituent parts for the purpose of analysis. While acknowledging that the actual journey articulated by each participant is a more complex whole than the sum of its parts, key empirically-based claims are presented as per the dimensional framework employed: contextuality; emotionality; temporo-spatiality. As a result of applying the foci of an international literature to an under-researched aspect of Irish education, this study is offered as a context-specific contribution to the knowledge base on beginning teaching. As the developmental needs of beginning teachers constitute an emerging area of intense policy focus in Ireland, this research undertaking is both relevant and timely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis work covered the fabrication and characterisation of impedance sensors for biological applications aiming in particular to the cytotoxicity monitoring of cultured cells exposed to different kind of chemical compounds and drugs and to the identification of different types of biological tissue (fat, muscles, nerves) using a sensor fabricated on the tip of a commercially available needle during peripheral nerve block procedures. Gold impedance electrodes have been successfully fabricated for impedance measurement on cells cultured on the electrode surface which was modified with the fabrication of gold nanopillars. These nanostructures have a height of 60nm or 100nm and they have highly ordered layout as they are fabricated through the e-beam technique. The fabrication of the threedimensional structures on the interdigitated electrodes was supposed to improve the sensitivity of the ECIS (electric cell-substrate impedance sensing) measurement while monitoring the cytotoxicity effects of two different drugs (Antrodia Camphorata extract and Nicotine) on three different cell lines (HeLa, A549 and BALBc 3T3) cultured on the impedance devices and change the morphology of the cells growing on the nanostructured electrodes. The fabrication of the nanostructures was achieved combining techniques like UV lithography, metal lift-off, evaporation and e-beam lithography techniques. The electrodes were packaged using a pressure sensitive, medical grade adhesive double-sided tape. The electrodes were then characterised with the aid of AFM and SEM imaging which confirmed the success of the fabrication processes showing the nanopillars fabricated with the right layout and dimensions figures. The introduction of nanopillars on the impedance electrodes, however, did not improve much the sensitivity of the assay with the exception of tests carried out with Nicotine. HeLa and A549 cells appeared to grow in a different way on the two surfaces, while no differences where noticed on the BALBc 3T3 cells. Impedance measurements obtained with the dead cells on the negative control electrodes or the test electrodes with the drugs can be compared to those done on the electrodes containing just media in the tested volume (as no cells are attached and cover the electrode surface). The impedance figures recorded using these electrodes were between 1.5kΩ and 2.5 kΩ, while the figures recorded on confluent cell layers range between 4kΩ and 5.5kΩ with peaks of almost 7 kΩ if there was more than one layer of cells growing on each other. There was then a very clear separation between the values of living cell compared to the dead ones which was almost 2.5 - 3kΩ. In this way it was very easy to determine whether the drugs affected the cells normal life cycle on not. However, little or no differences were noticed in the impedance analysis carried out on the two different kinds of electrodes using cultured cells. An increase of sensitivity was noticed only in a couple of experiments carried out on A549 cells growing on the nanostructured electrodes and exposed to different concentration of a solution containing Nicotine. More experiments to achieve a higher number of statistical evidences will be needed to prove these findings with an absolute confidence. The smart needle project aimed to reduce the limitations of the Electrical Nerve Stimulation (ENS) and the Ultra Sound Guided peripheral nerve block techniques giving the clinicians an additional tool for performing correctly the peripheral nerve block. Bioimpedance, as measured at the needle tip, provides additional information on needle tip location, thereby facilitating detection of intraneural needle placement. Using the needle as a precision instrument and guidance tool may provide additional information as to needle tip location and enhance safety in regional anaesthesia. In the time analysis, with the frequency fixed at 10kHz and the samples kept at 12°C, the approximate range for muscle bioimpedance was 203 – 616 Ω, the approximate bioimpedance range for fat was 5.02 - 17.8 kΩ and the approximate range for connective tissue was 790 Ω – 1.55 kΩ. While when the samples were heated at 37°C and measured again at 10kHz, the approximate bioimpedance range for muscle was 100-175Ω. The approximate bioimpedance range of fat was 627 Ω - 3.2 kΩ and the range for connective tissue was 221-540Ω. In the experiments done on the fresh slaughtered lamb carcass, replicating a scenario close to the real application, the impedance values recorded for fat were around 17 kΩ, for muscle and lean tissue around 1.3 kΩ while the nervous structures had an impedance value of 2.9 kΩ. With the data collected during this research, it was possible to conclude that measurements of bioimpedance at the needle tip location can give valuable information to the clinicians performing a peripheral nerve block procedure as the separation (in terms of impedance figures) was very marked between the different type of tissues. It is then feasible to use an impedance electrode fabricated on the needle tip to differentiate several tissues from the nerve tissue. Currently, several different methods are being studied to fabricate an impedance electrode on the surface of a commercially available needle used for the peripheral nerve block procedure.