2 resultados para Forensic Sciences.
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
There are difficulties with utilising self- report and physiological measures of assessment amongst forensic populations. This study investigates implicit based measures amongst sexual offenders, nonsexual offenders and low risk samples. Implicit measurement is a term applied to measurement methods that makes it difficult to influence responses through conscious control. The test battery includes the Implicit Association Test (IAT), Rapid Serial Visual Presentation (RSVP), Viewing Time (VT) and the Structured Clinical interview for disorders. The IAT proposes that people will perform better on a task when they depend on well-practiced cognitive associations. The RSVP task requires participants to identify a single target image that is presented amongst a series of rapidly presented visual images. RSVP operates on the premise that if two target images are presented within 500milliseconds of each other, the possibility that the participant will recognize the second target is significantly reduced when the first target is of salience to the individual. This is the attentional blink phenomenon. VT is based on the principle that people will look longer at images that are of salience. Results showed that on the VT task, child sexual offenders took longer to view images of children than low risk groups. Nude over clothed images induced a greater attentional blink amongst low risk and offending samples on the RSVP task. Sexual offenders took longer than low risk groups on word pairing tasks where sexual words were paired with adult words on the IAT. The SCID highlighted differences between the offending and non offending groups on the sub scales for personality disorders. More erotic stimulus items on the VT and RSVP measures is recommended to better differentiate sexual preference between offending and non offending samples. A pictorial IAT is recommended. Findings provide the basis for further development of implicit measures within the assessment of sexual offenders.
Resumo:
In developing a biosensor, the utmost important aspects that need to be emphasized are the specificity and selectivity of the transducer. These two vital prerequisites are of paramount in ensuring a robust and reliable biosensor. Improvements in electrochemical sensors can be achieved by using microelectrodes and to modify the electrode surface (using chemical or biological recognition layers to improve the sensitivity and selectivity). The fabrication and characterisations of silicon-based and glass-based gold microelectrode arrays with various geometries (band and disc) and dimension (ranging from 10 μm-100 nm) were reported. It was found that silicon-based transducers of 10 μm gold microelectrode array exhibited the most stable and reproducible electrochemical measurements hence this dimension was selected for further study. Chemical electrodeposition on both 10 μm microband and microdisc were found viable by electro-assisted self-assembled sol-gel silica film and nanoporous-gold electrodeposition respectively. The fabrication and characterisations of on-chip electrochemical cell was also reported with a fixed diameter/width dimension and interspacing variation. With this regard, the 10 μm microelectrode array with interspacing distance of 100 μm exhibited the best electrochemical response. Surface functionalisations on single chip of planar gold macroelectrodes were also studied for the immobilisation of histidine-tagged protein and antibody. Imaging techniques such as atomic force microscopy, fluorescent microscopy or scanning electron microscope were employed to complement the electrochemical characterisations. The long-chain thiol of self-assembled monolayer with NTA-metal ligand coordination was selected for the histidine-tagged protein while silanisation technique was selected for the antibody immobilisation. The final part of the thesis described the development of a T-2 labelless immunosensor using impedimetric approach. Good antibody calibration curve was obtained for both 10 μm microband and 10 μm microdisc array. For the establishment of the T-2/HT-2 toxin calibration curve, it was found that larger microdisc array dimension was required to produce better calibration curve. The calibration curves established in buffer solution show that the microelectrode arrays were sensitive and able to detect levels of T-2/HT-2 toxin as low as 25 ppb (25 μg kg-1) with a limit of quantitation of 4.89 ppb for a 10 μm microband array and 1.53 ppb for the 40 μm microdisc array.