4 resultados para Forearm fractures
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
This PhD thesis describes work carried out on investigation of various interventions with the aim to optimise the anaesthetic management of patients scheduled to undergo operative fixation of hip fractures. We analysed the perioperative effects of continuous femoral nerve block, single preoperative dose of i.v. dexamethasone, the intention to deposit local anaesthetic in different locations around the femoral nerve during ultrasound guided femoral nerve block, continuous spinal anaesthesia and peri-surgical site infiltration with local anaesthetic after surgical fixation of hip fractures. Continuous femoral nerve block provided more effective preoperative analgesia six hours after the insertion of the perineural catheter compared to a standard opiate-based regimen in patients undergoing operative fixation of fractured hip. A single low dose of preoperative dexamethasone in the intervention group decreased pain scores by 75% six hours after the surgery. Both interventions had no major effect on the functional recovery in the first year after the surgical fixation of fractured hip. The results of the ultrasound guided femoral nerve block trial showed no clinical advantage of intending to deposit local anaesthetic circumferentially during performing femoral nerve block. Using the Dixon and Massey’s “up- and-down” method, we demonstrated that intrathecal 0.26 ml of 0.5% bupivacaine provided adequate surgical anaesthesia within 15 minutes in 50% of patients undergoing operative fixation of hip fracture. Finally, we demonstrated that local anaesthetic infiltration had no effect on pain scores 12 hours after the surgical fixation of fractured neck of femur. In addition to this original body of work, a review article was published on femoral nerve block highlighting the use of ultrasound guidance. In conclusion, the results of this thesis offer an insight into interventions aimed at optimising perioperative analgesia in patients scheduled to undergo operative fixation of hip fractures.
Resumo:
Background: For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Methods: Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Findings: Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). Interpretation: These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible.
Resumo:
In this work, we investigate tennis stroke recognition using a single inertial measuring unit attached to a player’s forearm during a competitive match. This paper evaluates the best approach for stroke detection using either accelerometers, gyroscopes or magnetometers, which are embedded into the inertial measuring unit. This work concludes what is the optimal training data set for stroke classification and proves that classifiers can perform well when tested on players who were not used to train the classifier. This work provides a significant step forward for our overall goal, which is to develop next generation sports coaching tools using both inertial and visual sensors in an instrumented indoor sporting environment.
Resumo:
Chronic Kidney Disease (CKD), osteoporosis and mild hyponatremia are all prevalent chronic conditions that may coexist and are often under-recognized. Mineral-Bone Disorder begins early in the natural history of CKD and results in complex abnormalities of bone which ultimately confers a well-established increased risk of fragility fractures in End Stage Kidney Disease. Hyponatremia is a novel, usually renal mediated metabolic perturbation, that most commonly occurs independently of the stage of renal dysfunction but which may also predispose to increased fracture risk. The extent -if any- to which either early stages of renal dysfunction or the presence of hyponatremia contribute to fracture occurrence in the general population, independently of osteoporosis, is unclear. Renal transplantation is the treatment of choice for ESKD and although it restores endogenous renal function it typically fails to normalize either the long term cardiovascular or fracture risk. One potential mechanism contributing to these elevated long-term risks and to diminished Health Related Quality of Life is persistent, post-transplant hyperparathyroidism. In this study we retrospectively examine the association of renal function and serum sodium with Bone Mineral Density and fracture occurrence in a retrospective cohort of 1930 female members of the general population who underwent routine DXA scan. We then prospectively recruited a cohort of 90 renal transplant recipients in order to examine the association of post transplant parathyroid hormone (PTH) level with measures of CKD Mineral Bone Disorder, including, DXA Bone Mineral Density, Vascular Calcification (assessed using both abdominal radiography and CT techniques, as well as indirectly by carotid-femoral Pulse Wave Velocity) and Quality of Life (using the Short Form-12 and a PTH specific symptom score). In the retrospective DXA cohort, moderate CKD (eGFR 30-59ml/min/1.73m2) and hyponatremia (<135mmol/L) were associated with fracture occurrence, independently of BMD, with an adjusted Odds Ratio (95% Confidence Interval), of 1.37 (1.0, 1.89) and 2.25 (1.24, 4.09) respectively. In the renal transplant study, PTH was independently associated with the presence of osteoporosis, adjusted Odds Ratio (95% Confidence Interval), 1.15 (per 10ng/ml increment), (1.04, 1.26). The presence of osteoporosis but not PTH was independently associated with measures of vascular calcification, adjusted ß (95% Confidence Interval), 12.45, (1.16, 23.75). Of the eight quality-of-life domains examined, post-transplant PTH (per 10ng/ml increment), was only significantly and independently associated with reduced Physical Functioning, (95% Confidence Interval), 1.12 (1.01, 1.23). CKD and hyponatremia are both common health problems that may contribute to fracture occurrence in the general population, a major on-going public health concern. PTH and decreased Bone Mineral Density may signal sub-optimal long-term outcomes post renal transplantation, influencing bone and vascular health and to a limited extent long term Health Related Quality of Life