4 resultados para Effective method
em CORA - Cork Open Research Archive - University College Cork - Ireland
Resumo:
Various techniques and devices have been developed for the purpose of detecting wildlife but many only provide optimum results in particular habitats, for certain species or under ideal weather conditions. It is therefore advantageous to understand the efficiency and suitability of techniques under different scenarios. The effectiveness of methods for detecting rural Irish hedgehogs was investigated as part of a larger study in April 2008. Road kill sightings and questionnaires were employed to locate possible hedgehog sites. Six sites were subsequently selected, and in these areas trapping, spotlighting and foot print tunnels were employed to investigate whether hedgehogs were indeed in the surrounding landscape. Infrared thermal imagery was examined as a detection device. Trapping and infrared imagery failed to detect hedgehogs in areas where they had previously been recorded. Footprint tunnels proved to be unsuccessful in providing absolute proof of hedgehogs in an area. No single method of detection technique could be relied upon to conclude the presence of hedgehogs in an area. A combination of methods is therefore recommended. However, spotlighting was the most effective method, taking a mean of 4 nights to detect a hedgehog, in comparison to 48 nights if footprint tunnels were used as a sole method of detection. This was also suggested by rarefaction curves of these two detection techniques, where over a 48 night period hedgehogs were expected to be recorded 27 times through spotlighting and just 5 times in an equivalent period of footprint tunnel nights.
Resumo:
Prior work of our research group, that quantified the alarming levels of radiation dose to patients with Crohn’s disease from medical imaging and the notable shift towards CT imaging making these patients an at risk group, provided context for this work. CT delivers some of the highest doses of ionising radiation in diagnostic radiology. Once a medical imaging examination is deemed justified, there is an onus on the imaging team to endeavour to produce diagnostic quality CT images at the lowest possible radiation dose to that patient. The fundamental limitation with conventional CT raw data reconstruction was the inherent coupling of administered radiation dose with observed image noise – the lower the radiation dose, the noisier the image. The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation allowing either an improvement in image quality without increasing radiation dose or maintenance of image quality at a lower radiation dose compared with traditional image reconstruction. This thesis is fundamentally an exercise in optimisation in clinical CT practice with the objectives of assessment of iterative reconstruction as a method for improvement of image quality in CT, exploration of the associated potential for radiation dose reduction, and development of a new split dose CT protocol with the aim of achieving and validating diagnostic quality submillisiever t CT imaging in patients with Crohn’s disease. In this study, we investigated the interplay of user-selected parameters on radiation dose and image quality in phantoms and cadavers, comparing traditional filtered back projection (FBP) with iterative reconstruction algorithms. This resulted in the development of an optimised, refined and appropriate split dose protocol for CT of the abdomen and pelvis in clinical patients with Crohn’s disease allowing contemporaneous acquisition of both modified and conventional dose CT studies. This novel algorithm was then applied to 50 patients with a suspected acute complication of known Crohn’s disease and the raw data reconstructed with FBP, adaptive statistical iterative reconstruction (ASiR) and model based iterative reconstruction (MBIR). Conventional dose CT images with FBP reconstruction were used as the reference standard with which the modified dose CT images were compared in terms of radiation dose, diagnostic findings and image quality indices. As there are multiple possible user-selected strengths of ASiR available, these were compared in terms of image quality to determine the optimal strength for this modified dose CT protocol. Modified dose CT images with MBIR were also compared with contemporaneous abdominal radiograph, where performed, in terms of diagnostic yield and radiation dose. Finally, attenuation measurements in organs, tissues, etc. with each reconstruction algorithm were compared to assess for preservation of tissue characterisation capabilities. In the phantom and cadaveric models, both forms of iterative reconstruction examined (ASiR and MBIR) were superior to FBP across a wide variety of imaging protocols, with MBIR superior to ASiR in all areas other than reconstruction speed. We established that ASiR appears to work to a target percentage noise reduction whilst MBIR works to a target residual level of absolute noise in the image. Modified dose CT images reconstructed with both ASiR and MBIR were non-inferior to conventional dose CT with FBP in terms of diagnostic findings, despite reduced subjective and objective indices of image quality. Mean dose reductions of 72.9-73.5% were achieved with the modified dose protocol with a mean effective dose of 1.26mSv. MBIR was again demonstrated superior to ASiR in terms of image quality. The overall optimal ASiR strength for the modified dose protocol used in this work is ASiR 80%, as this provides the most favourable balance of peak subjective image quality indices with less objective image noise than the corresponding conventional dose CT images reconstructed with FBP. Despite guidelines to the contrary, abdominal radiographs are still often used in the initial imaging of patients with a suspected complication of Crohn’s disease. We confirmed the superiority of modified dose CT with MBIR over abdominal radiographs at comparable doses in detection of Crohn’s disease and non-Crohn’s disease related findings. Finally, we demonstrated (in phantoms, cadavers and in vivo) that attenuation values do not change significantly across reconstruction algorithms meaning preserved tissue characterisation capabilities with iterative reconstruction. Both adaptive statistical and model based iterative reconstruction algorithms represent feasible methods of facilitating acquisition diagnostic quality CT images of the abdomen and pelvis in patients with Crohn’s disease at markedly reduced radiation doses. Our modified dose CT protocol allows dose savings of up to 73.5% compared with conventional dose CT, meaning submillisievert imaging is possible in many of these patients.
Resumo:
Objective: Elevated levels of alcohol consumption among university students are well documented. Policymakers have attempted to combat this issue at a university, national and international level. Tailoring public health policy to effectively tackle alcohol use is crucial. Using Q-methodology, the current study aims to develop a typology of alcohol consumption in the Irish university student population. Setting: A large Irish university. Participants Hundreds of possible statements on types of consumption were generated from a systematic review and a set of one-on-one interviews. These were reduced to 36 statements, 6 statements which define each of the 6 previously defined consumption types. Participants were advised to scan through the 36 statements and fill the statements into a ‘forced choice, standardised distribution’. Following this, a 45–90 min interview was conducted with students to illuminate subjectivity surrounding alcohol consumption. Analysis was conducted using PQ Method and NVivo software. Principal component analysis, followed by varimax rotation, was conducted to uncover the final factor information. Results: In total, 43 students completed the Q-study: 19 men and 24 women. A typology describing 4 distinct groupings of alcohol consumer was uncovered: the guarded drinker, the calculated hedonist, the peer-influenced drinker and the inevitable binger. Factor loadings of each of the consumer groupings were noted for type description. Conclusions: This is the first study to propose ideal types of alcohol consumption among a university student population. Further research is required to investigate the degree to which each of these ideal types is subscribed. However, this typology, in addition to informing public policy and strategies, will be a valuable analytic tool in future research.
Resumo:
Since precise linear actuators of a compliant parallel manipulator suffer from their inability to tolerate the transverse motion/load in the multi-axis motion, actuation isolation should be considered in the compliant manipulator design to eliminate the transverse motion at the point of actuation. This paper presents an effective design method for constructing compliant parallel manipulators with actuation isolation, by adding the same number of actuation legs as the number of the DOF (degree of freedom) of the original mechanism. The method is demonstrated by two design case studies, one of which is quantitatively studied by analytical modelling. The modelling results confirm possible inherent issues of the proposed structure design method such as increased primary stiffness, introduced extra parasitic motions and cross-axis coupling motions.