4 resultados para Dental restoration wear

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To study the outcomes for restored primary molar teeth; to examine outcomes in relation to tooth type involved, intracoronal restoration complexity and to the material used. Materials and methods: Design: Retrospective study of primary molar teeth restored by intracoronal restorations. A series of restored primary molar teeth for children aged 6-12 years was studied. The principal outcome measure was failure of initial restoration (re-restoration or extraction). Three hundred patient records were studied to include three equal groups of primary molar teeth restored with amalgam, composite or glass ionomer, respectively. Restorative materials, the restoration type, simple (single surface) or complex (multi-surface) restoration, and tooth notation were recorded. Subsequent interventions were examined. Data were coded and entered into a Microsoft Excel database and analysis undertaken using SPSS v.18. Statistical differences were tested using the c2 test of statistical significance. Results: Of the 300 teeth studied, 61 restoration failures were recorded with 11 of those extracted. No significant differences were found between outcomes for upper first, upper second, lower first or lower second primary molars. Outcomes for simple primary teeth restored by intracoronal restorations were significantly better than those for complex intracoronal restorations (P = 0.042). Teeth originally restored with amalgam accounted for 19.7% of the 61 failures, composite for 29.5%, while teeth restored with glass ionomer represented 50.8% of all restoration failures. The differences were significant (P = 0.012). Conclusions: The majority (79.7%) of the 300 restored primary teeth studied were successful, and 3.7% teeth were extracted. Restorations involving more than one surface had almost twice the failure rate of single surface restorations. The difference was significant. Significant differences in failure rates for the three dental materials studied were recorded. Amalgam had the lowest failure rate while the failure rate with glass ionomer was the highest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: to assess elderly patients’ dental status and dental habits and compare the survival rates, impact on patients’ quality of life and cost-effectiveness of Atraumatic Restorative Treatment (ART) and a conventional treatment (CT) to restore carious lesions in an elderly population. Methods: In this randomised clinical trial, 99 independently living adults (65-90 yrs) with carious lesions were randomly allocated to receive either ART or CT. Details of restored, missing and carious teeth were recorded and patients answered some questions about their oral hygiene and dental attendance habits. Direct and indirect costs were measured based on treatment time, materials and labour. Effectiveness was measured using restoration survival percentage after one year. The survival of restorations was assessed 6 months and one year after restoration placement by an independent examiner. Oralhealth related quality of life (OHRQoL) was assessed using the OHIP-14 at baseline and 2 months after treatment together with a global transition statement. Results: The patient sample comprised 46 (46.46%) male and 53 (53.54) female participants at baseline, with a mean age of 73.18 (SD=6.76). The mean DMFT of the entire sample was 27.10. Ninety patients and 268 restorations could be assessed after one year, 127 ART (46 patients) and 141 conventional restorations (44 patients). 93.7% and 97.2% of the restorations placed were considered successful in the ART and CT groups, respectively. The OHIP scores did not change dramatically 2 months after treatment, in either group. The global transition scale showed an improvement in overall oral health after treatment for the majority of patients. The ART were more cost-effective compared to the CT restorations. Conclusions: ART presented survival rates similar to CT after 1 year and was a more cost-effective alternative to treat the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To identify factors influencing attitudes of partially dentate adults towards dental treatment in Ireland. Background: People are retaining more teeth later in life than ever before. Management of partially dentate older adults will be a major requirement for the future and it is important to determine factors which may influence patients’ attitudes to care. Methods: Subjects: A purposive sample of 22 partially dentate patients was recruited; 12 women and 12 men, ranging in age from 45 to 75 years. Data Collection: Semi-structured individual interviews. Results: Dental patients have increasing expectations in relation to (i) a more sophisticated approach to the management of missing teeth and (ii) their right to actively participate in decision making regarding the management of their tooth loss. There is some evidence of a cohort effect with younger patients (45–64 years) having higher expectations. Conclusions: The evidence of a cohort effect within this study in relation to higher patient expectations indicates that both contemporary and future patients are likely to seek a service based on conservation and restoration of missing teeth by fixed prostheses.