8 resultados para Crescent-shaped bracesseismicanalysisperformace-based design

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The flip-chip technology is a high chip density solution to meet the demand for very large scale integration design. For wireless sensor node or some similar RF applications, due to the growing requirements for the wearable and implantable implementations, flip-chip appears to be a leading technology to realize the integration and miniaturization. In this paper, flip-chip is considered as part of the whole system to affect the RF performance. A simulation based design is presented to transfer the surface mount PCB board to the flip-chip die package for the RF applications. Models are built by Q3D Extractor to extract the equivalent circuit based on the parasitic parameters of the interconnections, for both bare die and wire-bonding technologies. All the parameters and the PCB layout and stack-up are then modeled in the essential parts' design of the flip-chip RF circuit. By implementing simulation and optimization, a flip-chip package is re-designed by the parameters given by simulation sweep. Experimental results fit the simulation well for the comparison between pre-optimization and post-optimization of the bare die package's return loss performance. This design method could generally be used to transfer any surface mount PCB to flip-chip package for the RF systems or to predict the RF specifications of a RF system using the flip-chip technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Practices are routinised behaviours with social and material components and complex relationships over space and time. Practice-based design goes beyond interaction design to consider how these components and their relationships impact on the formation and enactment of a practice, where technology is just one part of the practice. Though situated user-centred design methods such as participatory design are employed for the design of practice, demand exists for additional methods and tools in this area. This paper introduces practice-based personas as an extension of the persona approach popular in interaction design, and demonstrates how a set of practice-based personas was developed for a given domain – academic practice. The three practice-based personas developed here are linked to a catalogue of forty practices, offering designers both a user perspective and a practice perspective when designing for the domain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerous works have been conducted on modelling basic compliant elements such as wire beams, and closed-form analytical models of most basic compliant elements have been well developed. However, the modelling of complex compliant mechanisms is still a challenging work. This paper proposes a constraint-force-based (CFB) modelling approach to model compliant mechanisms with a particular emphasis on modelling complex compliant mechanisms. The proposed CFB modelling approach can be regarded as an improved free-body- diagram (FBD) based modelling approach, and can be extended to a development of the screw-theory-based design approach. A compliant mechanism can be decomposed into rigid stages and compliant modules. A compliant module can offer elastic forces due to its deformation. Such elastic forces are regarded as variable constraint forces in the CFB modelling approach. Additionally, the CFB modelling approach defines external forces applied on a compliant mechanism as constant constraint forces. If a compliant mechanism is at static equilibrium, all the rigid stages are also at static equilibrium under the influence of the variable and constant constraint forces. Therefore, the constraint force equilibrium equations for all the rigid stages can be obtained, and the analytical model of the compliant mechanism can be derived based on the constraint force equilibrium equations. The CFB modelling approach can model a compliant mechanism linearly and nonlinearly, can obtain displacements of any points of the rigid stages, and allows external forces to be exerted on any positions of the rigid stages. Compared with the FBD based modelling approach, the CFB modelling approach does not need to identify the possible deformed configuration of a complex compliant mechanism to obtain the geometric compatibility conditions and the force equilibrium equations. Additionally, the mathematical expressions in the CFB approach have an easily understood physical meaning. Using the CFB modelling approach, the variable constraint forces of three compliant modules, a wire beam, a four-beam compliant module and an eight-beam compliant module, have been derived in this paper. Based on these variable constraint forces, the linear and non-linear models of a decoupled XYZ compliant parallel mechanism are derived, and verified by FEA simulations and experimental tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Can my immediate physical environment affect how I feel? The instinctive answer to this question must be a resounding “yes”. What might seem a throwaway remark is increasingly borne out by research in environmental and behavioural psychology, and in the more recent discipline of Evidence-Based Design. Research outcomes are beginning to converge with findings in neuroscience and neurophysiology, as we discover more about how the human brain and body functions, and reacts to environmental stimuli. What we see, hear, touch, and sense affects each of us psychologically and, by extension, physically, on a continual basis. The physical characteristics of our daily environment thus have the capacity to profoundly affect all aspects of our functioning, from biological systems to cognitive ability. This has long been understood on an intuitive basis, and utilised on a more conscious basis by architects and other designers. Recent research in evidence-based design, coupled with advances in neurophysiology, confirm what have been previously held as commonalities, but also illuminate an almost frightening potential to do enormous good, or alternatively, terrible harm, by virtue of how we make our everyday surroundings. The thesis adopts a design methodology in its approach to exploring the potential use of wireless sensor networks in environments for elderly people. Vitruvian principles of “commodity, firmness and delight” inform the research process and become embedded in the final design proposals and research conclusions. The issue of person-environment fit becomes a key principle in describing a model of continuously-evolving responsive architecture which makes the individual user its focus, with the intention of promoting wellbeing. The key research questions are: What are the key system characteristics of an adaptive therapeutic single-room environment? How can embedded technologies be utilised to maximise the adaptive and therapeutic aspects of the personal life-space of an elderly person with dementia?.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Humans are profoundly affected by the surroundings which they inhabit. Environmental psychologists have produced numerous credible theories describing optimal human environments, based on the concept of congruence or “fit” (1, 2). Lack of person/environment fit can lead to stress-related illness and lack of psychosocial well-being (3). Conversely, appropriately designed environments can promote wellness (4) or “salutogenesis” (5). Increasingly, research in the area of Evidence-Based Design, largely concentrated in the area of healthcare architecture, has tended to bear out these theories (6). Patients and long-term care residents, because of injury, illness or physical/ cognitive impairment, are less likely to be able to intervene to modify their immediate environment, unless this is designed specifically to facilitate their particular needs. In the context of care settings, detailed design of personal space therefore takes on enormous significance. MyRoom conceptualises a personalisable room, utilising sensoring and networked computing to enable the environment to respond directly and continuously to the occupant. Bio-signals collected and relayed to the system will actuate application(s) intended to positively influence user well-being. Drawing on the evidence base in relation to therapeutic design interventions (7), real-time changes in ambient lighting, colour, image, etc. respond continuously to the user’s physiological state, optimising congruence. Based on research evidence, consideration is also given to development of an application which uses natural images (8). It is envisaged that actuation will require machine-learning based on interpretation of data gathered by sensors; sensoring arrangements may vary depending on context and end-user. Such interventions aim to reduce inappropriate stress/ provide stimulation, supporting both instrumental and cognitive tasks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The absence of rapid, low cost and highly sensitive biodetection platform has hindered the implementation of next generation cheap and early stage clinical or home based point-of-care diagnostics. Label-free optical biosensing with high sensitivity, throughput, compactness, and low cost, plays an important role to resolve these diagnostic challenges and pushes the detection limit down to single molecule. Optical nanostructures, specifically the resonant waveguide grating (RWG) and nano-ribbon cavity based biodetection are promising in this context. The main element of this dissertation is design, fabrication and characterization of RWG sensors for different spectral regions (e.g. visible, near infrared) for use in label-free optical biosensing and also to explore different RWG parameters to maximize sensitivity and increase detection accuracy. Design and fabrication of the waveguide embedded resonant nano-cavity are also studied. Multi-parametric analyses were done using customized optical simulator to understand the operational principle of these sensors and more important the relationship between the physical design parameters and sensor sensitivities. Silicon nitride (SixNy) is a useful waveguide material because of its wide transparency across the whole infrared, visible and part of UV spectrum, and comparatively higher refractive index than glass substrate. SixNy based RWGs on glass substrate are designed and fabricated applying both electron beam lithography and low cost nano-imprint lithography techniques. A Chromium hard mask aided nano-fabrication technique is developed for making very high aspect ratio optical nano-structure on glass substrate. An aspect ratio of 10 for very narrow (~60 nm wide) grating lines is achieved which is the highest presented so far. The fabricated RWG sensors are characterized for both bulk (183.3 nm/RIU) and surface sensitivity (0.21nm/nm-layer), and then used for successful detection of Immunoglobulin-G (IgG) antibodies and antigen (~1μg/ml) both in buffer and serum. Widely used optical biosensors like surface plasmon resonance and optical microcavities are limited in the separation of bulk response from the surface binding events which is crucial for ultralow biosensing application with thermal or other perturbations. A RWG based dual resonance approach is proposed and verified by controlled experiments for separating the response of bulk and surface sensitivity. The dual resonance approach gives sensitivity ratio of 9.4 whereas the competitive polarization based approach can offer only 2.5. The improved performance of the dual resonance approach would help reducing probability of false reading in precise bio-assay experiments where thermal variations are probable like portable diagnostics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We analysed the use of microneedle-based electrodes to enhance electroporation of mouse testis with DNA vectors for production of transgenic mice. Different microneedle formats were developed and tested, and we ultimately used electrodes based on arrays of 500 μm tall microneedles. In a series of experiments involving injection of a DNA vector expressing Green Fluorescent Protein (GFP) and electroporation using microneedle electrodes and a commercially available voltage supply, we compared the performance of flat and microneedle electrodes by measuring GFP expression at various timepoints after electroporation. Our main finding, supported by both experimental and simulated data, is that needles significantly enhanced electroporation of testis.