2 resultados para Breast expander implants

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate women’s help seeking behavior (HSB) following self discovery of a breast symptom and determine the associated influencing factors. A descriptive correlation design was used to ascertain the help seeking behavior (HSB) and the associated influencing factors of a sample of women (n = 449) with self discovered breast symptoms. The study was guided by the ‘Help Seeking Behaviour and Influencing Factors” conceptual framework (Facione et al., 2002; Meechan et al., 2003, 2002; Leventhal, Brissette and Leventhal, 2003 and O’Mahony and Hegarty, 2009b). Data was collected using a researcher developed multi-scale questionnaire package to ascertain women’s help seeking behavior on self discovery of a breast symptom and determine the factors most associated with HSB. Factors examined include: socio-demographics, knowledge and beliefs (regarding breast symptom; breast changes associated with breast cancer; use of alternative help seeking behaviours and presence or absence of a family history of breast cancer),emotional responses, social factors, health seeking habits and health service system utilization and help seeking behavior. A convenience sample (n = 449 was obtained by the researcher from amongst women attending the breast clinics of two large urban hospitals within the Republic of Ireland. All participants had self-discovered breast symptoms and no previous history of breast cancer. The study identified that while the majority of women (69.9%; n=314) sought help within one month, 30.1% (n=135) delayed help seeking for more than one month following self discovery of their breast symptom. The factors most significantly associated with HSB were the presenting symptom of ‘nipple indrawn/changes’ (p = 0.005), ‘ignoring the symptom and hoping it would go away’ (p < 0.001), the emotional response of being ‘afraid@ on symptom discovery (p = 0.005) and the perception/belief in longer symptom duration (p = 0.023). It was found that women who presented with an indrawn/changed nipple were more likely to delay (OR = 4.81) as were women who ‘ignored the symptoms and hoped it would go away’ (OR = 10.717). Additionally, the longer women perceived that their symptom would last, they more likely they were to delay (OR = 1.18). Conversely, being afraid following symptom discovery was associated with less delay (OR = 0.37; p=0.005). This study provides further insight into the HSB of women who self discovered breast symptoms. It highlights the complexity of the help seeking process, indicating that is not a linear event but is influenced by multiple factors which can have a significant impact on the outcomes in terms of whether women delay or seek help promptly. The study further demonstrates that delayed HSB persists amongst women with self discovered breast symptoms. This has important implications for continued emphasis on the promotion of breast awareness, prompt help seeking for self discovered breast symptoms and early detection and treatment of breast cancer, amongst women of all ages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel deposition process named CoBlastTM, based on grit blasting technology, has been used to deposit hydroxyapatite (HA) onto titanium (Ti) metal using a dopant/abrasive regime. The various powders (HA powder, apatitic abrasives) and the treated substrates were characterised for chemical composition, coating coverage, crystallinity and topography including surface roughness. The surface roughness of the HA surfaces could be altered using apatitic abrasives of different particle sizes. Compared to the standard plasma spraying process, the CoBlast surface produced excellent coating adhesion, lower dissolution, higher levels of mechanical and chemical stability in stimulated body fluid (SBF). Enhanced viability of osteoblastic cells was also observed on the CoBlast HA surfaces compared to the microblast and untreated Ti as well as the plasma HA coating. CoBlast offers an alternative to the traditional methods of coating HA implants with added versatility. Apatites substituted with antimicrobial metals can also be deposited to add functionality to HA coatings without cytotoxicty. The potential use of these coatings as an infection preventing strategy for application on hard tissue implants was assessed in vitro and also in vivo. Surface physicochemical properties and morphology were determined in addition to surface cytocompatibility assessments using a MG-63 osteoblast cell line. The antibacterial potential of the immobilised metal ion on the surface and the eluted ion to a lesser extent, contributed to the anticolonising behaviour of the surfaces against a standard bacteria strain (S. aureus) as well as a number of clinically relevant strains (MRSA, MSSA and S. epidermis). The results revealed that the surfaces coated with silver substituted apatites (AgA) outperformed the other apatites examined (apatites loaded with Zn, Sr and both Ag and Sr ions). Assessment of bacterial adherence on coated K-wires following subcutaneous implantation in a nude mouse infection model (S. aureus) for two days demonstrated that the 12% wt surface outperformed the 5% wt AgA coating. Lower inflammatory responses were activated with the insertion of the Ag loaded K-wires with a localised infection at the implantation site noted over the two day study period. These results indicated that the AgA coating on the surface of orthopaedic implants demonstrate good biocompatibility whilst inhibiting bacterial adhesion and colonising of the implant surface.