2 resultados para O mobility
em Academic Archive On-line (Jönköping University
Resumo:
The aim of the thesis was to collect baseline data and to investigating suitable physical tests and a self-rapport questionnaire. Collected data was used to find a routine measurement when investigating foot health, function and mobility among clients suffering from diabetes in Samoa. Twenty-one participants suffering from diabetes were included in the study. Clients answered the Foot function index (FFI) questionnaire and performed physical tests, consisting of Bergs balance scale (BBS) and Time up and go (TUG). Results from the physical tests revealed a great balance disturbance and mobility limitations among the majority of the clients. General high weight and BMI was measured among both genders. Subjects with the highest BMI performed lowest time during TUG test. The statistic analyze revealed a strong correlation between the two physical tests, indicating that one of the tests could be applied as a routine measurement in the future, when evaluating function and mobility in Samoa. The compilation of self-report questionnaires indicated a general good foot health with a low amount of pain, disabilities and activity limitations.
Resumo:
Objectives: To investigate patients' mobility and satisfaction with their lower-limb prosthetic or orthotic device and related service delivery in Sierra Leone; to compare groups of patients regarding type and level of assistive device, gender, area of residence, income; and to identify factors associated with satisfaction with the assistive device and service. Methods: A total of 139 patients answered questionnaires, including the Quebec User Evaluation of Satisfaction with Assistive Technology questionnaire (QUEST 2.0). Results: Eighty-six percent of assistive devices were in use, but half needed repair. Thirty-three percent of patients reported pain when using their assistive device. Patients had difficulties or could not walk at all on: uneven ground (65%); hills (75%); and stairs (66%). Patients were quite satisfied with their assistive device and the service (mean 3.7 out of 5 in QUEST), but reported 886 problems. Approximately half of the patients could not access services. In relation to mobility and service delivery, women, orthotic patients and patients using above-knee assistive devices had the poorest results. The general condition of the assistive device and patients' ability to walk on uneven ground were associated with satisfaction with the assistive devices and service. Conclusion: Patients reported high levels of mobility while using their device although they experienced pain and difficulties walking on challenging surfaces. Limitations in the effectiveness of assistive devices and limited access to follow-up services and repairs were issues desired to be addressed.