2 resultados para pulmonary function decline

em ABACUS. Repositorio de Producción Científica - Universidad Europea


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The background of this study is to assess the accuracy of lung ultrasound (LUS) to diagnose interstitial lung disease (ILD) in Sjögren’s syndrome (Sjs), in patients who have any alterations in pulmonary function tests (PFT) or respiratory symptoms. LUS was correlated with chest tomography (hrCT), considering it as the imaging gold standard technique to diagnose ILD. This is a pilot, multicenter, cross-sectional, and consecutive-case study. The inclusion criteria are ≥18 years old, Signs and symptoms: according to ACEG 2002 criteria, respiratory symptoms (dyspnea, cough), or any alterations in PFR. LUS was done following the International Consensus Conference on Lung Ultrasound protocol for interstitial syndrome (B pattern). Of the 50 patients in follow-up, 13 (26%) met the inclusion criteria. All were women with age 63.62 years (range 39–88). 78.6% of the cases had primary Sjs (SLE, RA, n = 2). The intra-rater reliability k is 1, according to Gwet’s Ac1 and GI index (probability to concordance—e(K)—, by Cohen, of 0.52). LUS has a sensitivity of 1 (95% CI 0.398–1.0), specificity of 0.89 (95% CI 0.518–0.997), and a positive probability reason of 9.00 (95% CI 7.1–11.3) to detect ILD. The correlation of Pearson is r = 0.84 (p < 0.001). To check the accuracy of LUS to diagnose ILD, a completely bilateral criterion of yes/no for interstitial pattern was chosen, AUC reaches significance, 0.94 (0.07) (95% CI 0.81–1.0, p = 0.014). LUS reaches an excellent correlation to hrCT in Sjs affected with ILD, and might be a useful technique in daily clinical practice for the assessment of pulmonary disease in the sicca syndrome. © 2016 SIMI

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanisms contributing to pulmonary and systemic injury induced by high tidal volume (VT) mechanical ventilation are not well known. We tested the hypothesis that increased peroxynitrite formation is involved in organ injury and dysfunction induced by mechanical ventilation. Male Sprague-Dawley rats were subject to low- (VT, 9 mL/kg; positive end-expiratory pressure, 5 cmH2O) or high- (VT, 25 mL/kg; positive end-expiratory pressure, 0 cmH2O) VT mechanical ventilation for 120 min, and received 1 of 3 treatments: 3-aminobenzamide (3-AB, 10 mg/kg, intravenous, a poly adenosine diphosphate ribose polymerase [PARP] inhibitor), or the metalloporphyrin manganese(III) tetrakis(1-methyl-4-pyridyl)porphyrin (MnTMPyP, 5 mg/kg intravenous, a peroxynitrite scavenger), or no treatment (control group), 30 min before starting the mechanical ventilation protocol (n = 8 per group, 6 treatment groups). We measured mean arterial pressure, peak inspiratory airway pressure, blood chemistry, and gas exchange. Oxidation (fluorescence for oxidized dihydroethidium), protein nitration (immunofluorescence and Western blot for 3-nitrotyrosine), PARP protein (Western blot) and gene expression of the nitric oxide (NO) synthase (NOS) isoforms (quantitative real-time reverse transcription polymerase chain reaction) were measured in lung and vascular tissue. Lung injury was quantified by light microscopy. High-VT mechanical ventilation was associated with hypotension, increased peak inspiratory airway pressure, worsened oxygenation; oxidation and protein nitration in lung and aortic tissue; increased PARP protein in lung; up-regulation of NOS isoforms in lung tissue; signs of diffuse alveolar damage at histological examination. Treatment with 3AB or MnTMPyP attenuated the high-VT mechanical ventilation-induced changes in pulmonary and cardiovascular function; down-regulated the expression of NOS1, NOS2, and NOS3; decreased oxidation and nitration in lung and aortic tissue; and attenuated histological changes. Increased peroxynitrite formation is involved in mechanical ventilation-induced pulmonary and vascular dysfunction.