3 resultados para Arritmia Sinusal

em ABACUS. Repositorio de Producción Científica - Universidad Europea


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial fibrosis detected via delayed-enhanced magnetic resonance imaging (MRI) has been shown to be a strong indicator for ventricular tachycardia (VT) inducibility. However, little is known regarding how inducibility is affected by the details of the fibrosis extent, morphology, and border zone configuration. The objective of this article is to systematically study the arrhythmogenic effects of fibrosis geometry and extent, specifically on VT inducibility and maintenance. We present a set of methods for constructing patient-specific computational models of human ventricles using in vivo MRI data for patients suffering from hypertension, hypercholesterolemia, and chronic myocardial infarction. Additional synthesized models with morphologically varied extents of fibrosis and gray zone (GZ) distribution were derived to study the alterations in the arrhythmia induction and reentry patterns. Detailed electrophysiological simulations demonstrated that (1) VT morphology was highly dependent on the extent of fibrosis, which acts as a structural substrate, (2) reentry tended to be anchored to the fibrosis edges and showed transmural conduction of activations through narrow channels formed within fibrosis, and (3) increasing the extent of GZ within fibrosis tended to destabilize the structural reentry sites and aggravate the VT as compared to fibrotic regions of the same size and shape but with lower or no GZ. The approach and findings represent a significant step toward patient-specific cardiac modeling as a reliable tool for VT prediction and management of the patient. Sensitivities to approximation nuances in the modeling of structural pathology by image-based reconstruction techniques are also implicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data are lacking on the characteristics of atrial activity in centenarians, including interatrial block (IAB). The aim of this study was to describe the prevalence of IAB and auricular arrhythmias in subjects older than 100 years and to elucidate their clinical implications. We studied 80 centenarians (mean age 101.4 ± 1.5 years; 21 men) with follow-ups of 6–34 months. Of these 80 centenarians, 71 subjects (88.8%) underwent echocardiography. The control group comprised 269 septuagenarians. A total of 23 subjects (28.8%) had normal P wave, 16 (20%) had partial IAB, 21 (26%) had advanced IAB, and 20 (25.0%) had atrial fibrillation/flutter. The IAB groups exhibited premature atrial beats more frequently than did the normal P wave group (35.1% vs 17.4%; P < .001); also, other measurements in the IAB groups frequently fell between values observed in the normal P wave and the atrial fibrillation/flutter groups. These measurements included sex preponderance, mental status and dementia, perceived health status, significant mitral regurgitation, and mortality. The IAB group had a higher previous stroke rate (24.3%) than did other groups. Compared with septuagenarians, centenarians less frequently presented a normal P wave (28.8% vs 53.5%) and more frequently presented advanced IAB (26.3% vs 8.2%), atrial fibrillation/flutter (25.0% vs 10.0%), and premature atrial beats (28.3 vs 7.0%) (P < .01). Relatively few centenarians (<30%) had a normal P wave, and nearly half had IAB. Our data suggested that IAB, particularly advanced IAB, is a pre–atrial fibrillation condition associated with premature atrial beats. Atrial arrhythmias and IAB occurred more frequently in centenarians than in septuagenarians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La terapia de resincronización cardiaca se asocia a mejora de la calidad de vida y reducción de la morbimortalidad de los pacientes con disfunción ventricular grave y QRS ancho. Sobre su papel en la reducción de arritmias ventriculares, hay más discusión. Se comparó la incidencia de arritmias ventriculares en pacientes portadores de desfibrilador automático implantable con función de resincronización cardiaca, según el grado de respuesta ecocardiográfica a la resincronización. Se clasificó a los pacientes en tres subgrupos: superrespondedores, respondedores y no respondedores. Se incluyó a 196 pacientes seguidos durante una mediana de 30,1 [intervalo intercuartílico, 18,0-55,1] meses. Se documentó presencia de arritmias ventriculares en 37 pacientes (18,8%); 3 pacientes (5,9%) del grupo de superrespondedores presentaron arritmias ventriculares, en comparación con 14 (22,2%) del grupo de respondedores y 20 (24,4%) del grupo de no respondedores (p = 0,025). En el análisis multivariable, el implante del dispositivo en prevención secundaria (odds ratio = 4,04; intervalo de confianza del 95%, 1,52-10,75; p = 0,005), la ausencia de superrespuesta ecocardiográfica (odds ratio = 3,81; intervalo de confianza del 95%, 1,04-13,93; p = 0,043), un QRS > 160 ms (odds ratio = 2,39; intervalo de confianza del 95%, 1,00-1,35; p = 0,049) y el tratamiento con amiodarona (odds ratio = 2,47; intervalo de confianza del 95%, 1,03-5,91; p = 0,041) fueron los únicos predictores independientes de aparición de arritmias ventriculares. Los pacientes superrespondedores a la terapia de resincronización cardiaca presentan una disminución significativa en la incidencia de arritmias ventriculares respecto a los demás pacientes. Pese a ello, los episodios arrítmicos no llegan a desaparecer por completo en este subgrupo.