5 resultados para Smoke

em Repository Napier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This three movement work was first performed by members of the Research Ensemble at the Peninsula Arts Contemporary Music Festival, 26 February 2010. Material from the first movement reappears in the second and third in various guises. The second movement is dedicated to the choreographer, Merce Cunningham, and the constant piano part with pedal sustained throughout is a reference to the fluidity of dance. As a contrast to this there are passages of imitation between the horn and violin, some more audible than others, which are included as an acknowledgement of the intimate relationship which exists between co-dancers on stage. The third movement is dedicated to John Cage (Cunningham's partner) and, while the piano sustains chords (reworking content from the first movement), the gestures in the other parts loosely follow the outline of sections of one of Cage's watercolours, River Rocks and Smoke no.6. Much of my music is inspired by visual art and, having admired Cage's music and writings since by student days, it seemed appropriate after dedicating the second movement to Cunningham, to turn to Cage's art work in the final part of the composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Smoking restrictions in the workplace and increased health consciousness at home have seen a sizable reduction in the number of spaces where smoking is permissible. The aim of this study was to investigate the effects of ventilation in public houses, one of the few remaining public spaces where smoking is still socially acceptable. Little is known about the situation with shared occupancies, where relatively large areas are intended to accommodate both smokers and non-smokers. This study clearly identifies potential problems with a simplistic design approach to ventilation and its effectiveness in the context of shared occupancy spaces. A computational fluid dynamics code has been used to model airflows with the aim of identifying inefficiencies in existing ventilation systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is increasing evidence of a causal link between airborne particles and ill health and this study monitored the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a nightclub. The present study followed a number of pilot studies in which the human exposure to airborne particles in a nightclub was assessed and the spatio-temporal distribution of gas phase pollutants was evaluated in restaurants and pubs. The work reported here re-examined the nightclub environment and utilized concurrent and continuous monitoring using optical scattering samplers to measure particulates (PM10) together with multi-gas analysers. The analysis illustrated the highly episodic nature of both gaseous and particulate concentrations in both the dance floor and in the bar area but levels were well below the maximum recommended exposure levels. Short-term exposure to high concentrations may however be relevant when considering the possible toxic effects on biological systems. The results give an indication of the problems associated with achieving acceptable indoor air quality (IAQ) in a complex space and identified some of the problems inherent in the design and operation of ventilation systems for such spaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is increasing evidence of a causal link between airborne particles and ill health and this study examined the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a bar. The work reported here utilized concurrent and continuous monitoring using real-time optical scattering personal samplers to record particulate (PM10) concentrations at two internal locations. Very high episodes were observed in seating areas compared with the bar area. A photo-acoustic multi-gas analyser was used to record the gas phases (CO and CO2) at eight different locations throughout the bar and showed little spatial variation. This gave a clear indication of the problems associated with achieving acceptable Indoor Air Quality in a public space and identified a fundamental problem with the simplistic design approach taken to ventilate the space. Both gaseous and particulate concentrations within the bar were below maximum recommended levels although the time-series analysis illustrated the highly episodic nature of this exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge on human behaviour in emergency is crucial to increase the safety of buildings and transportation systems. Decision making during evacuations implies different choices, of which one of the most important concerns the escape route. The choice of a route may involve local decisions between alternative exits from an enclosed environment. This work investigates the influence of environmental (presence of smoke, emergency lighting and distance of exit) and social factors (interaction with evacuees close to the exits and with those near the decision-maker) on local exit choice. This goal is pursued using an online stated preference survey carried out making use of non-immersive virtual reality. A sample of 1,503 participants is obtained and a Mixed Logit Model is calibrated using these data. The model shows that presence of smoke, emergency lighting, distance of exit, number of evacuees near the exits and the decision-maker, and flow of evacuees through the exits significantly affect local exit choice. Moreover, the model points out that decision making is affected by a high degree of behavioural uncertainty. Our findings support the improvement of evacuation models and the accuracy of their results, which can assist in designing and managing building and transportation systems. The main contribution of this work is to enrich the understanding of how local exit choices are made and how behavioural uncertainty affects these choices.