8 resultados para Project 2004-033-B : Indoor Air Quality Estimator

em Repository Napier


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is increasing evidence of a causal link between airborne particles and ill health and this study monitored the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a nightclub. The present study followed a number of pilot studies in which the human exposure to airborne particles in a nightclub was assessed and the spatio-temporal distribution of gas phase pollutants was evaluated in restaurants and pubs. The work reported here re-examined the nightclub environment and utilized concurrent and continuous monitoring using optical scattering samplers to measure particulates (PM10) together with multi-gas analysers. The analysis illustrated the highly episodic nature of both gaseous and particulate concentrations in both the dance floor and in the bar area but levels were well below the maximum recommended exposure levels. Short-term exposure to high concentrations may however be relevant when considering the possible toxic effects on biological systems. The results give an indication of the problems associated with achieving acceptable indoor air quality (IAQ) in a complex space and identified some of the problems inherent in the design and operation of ventilation systems for such spaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is increasing evidence of a causal link between airborne particles and ill health and this study examined the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a bar. The work reported here utilized concurrent and continuous monitoring using real-time optical scattering personal samplers to record particulate (PM10) concentrations at two internal locations. Very high episodes were observed in seating areas compared with the bar area. A photo-acoustic multi-gas analyser was used to record the gas phases (CO and CO2) at eight different locations throughout the bar and showed little spatial variation. This gave a clear indication of the problems associated with achieving acceptable Indoor Air Quality in a public space and identified a fundamental problem with the simplistic design approach taken to ventilate the space. Both gaseous and particulate concentrations within the bar were below maximum recommended levels although the time-series analysis illustrated the highly episodic nature of this exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor and outdoor concentrations of various pollutants were measured in a naturally ventilated building in the West End of Edinburgh during and after the period of the Commonwealth Heads of Government Meeting (CHOGM) to assess the effect upon indoor pollution levels of the closure of some streets in the city. The relationships between indoor and outdoor air qualities in respect of traffic-generated pollutants were studied and the building’s relative attenuation of external pollution levels investigated. The peak concentrations of some of the external pollutants were attenuated by the building and the internal concentrations showed a reduction of up to 30% in some periods. During periods of reduced traffic, the early analyses indicate that the daily mean concentrations of the pollutants were not significantly different from those measured at other times.