4 resultados para Programs Of Care

em Repository Napier


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To develop sedation, pain, and agitation quality measures using process control methodology and evaluate their properties in clinical practice. Design: A Sedation Quality Assessment Tool was developed and validated to capture data for 12-hour periods of nursing care. Domains included pain/discomfort and sedation-agitation behaviors; sedative, analgesic, and neuromuscular blocking drug administration; ventilation status; and conditions potentially justifying deep sedation. Predefined sedation-related adverse events were recorded daily. Using an iterative process, algorithms were developed to describe the proportion of care periods with poor limb relaxation, poor ventilator synchronization, unnecessary deep sedation, agitation, and an overall optimum sedation metric. Proportion charts described processes over time (2 monthly intervals) for each ICU. The numbers of patients treated between sedation-related adverse events were described with G charts. Automated algorithms generated charts for 12 months of sequential data. Mean values for each process were calculated, and variation within and between ICUs explored qualitatively. Setting: Eight Scottish ICUs over a 12-month period. Patients: Mechanically ventilated patients. Interventions: None. Measurements and Main Results: The Sedation Quality Assessment Tool agitation-sedation domains correlated with the Richmond Sedation Agitation Scale score (Spearman [rho] = 0.75) and were reliable in clinician-clinician (weighted kappa; [kappa] = 0.66) and clinician-researcher ([kappa] = 0.82) comparisons. The limb movement domain had fair correlation with Behavioral Pain Scale ([rho] = 0.24) and was reliable in clinician-clinician ([kappa] = 0.58) and clinician-researcher ([kappa] = 0.45) comparisons. Ventilator synchronization correlated with Behavioral Pain Scale ([rho] = 0.54), and reliability in clinician-clinician ([kappa] = 0.29) and clinician-researcher ([kappa] = 0.42) comparisons was fair-moderate. Eight hundred twenty-five patients were enrolled (range, 59-235 across ICUs), providing 12,385 care periods for evaluation (range 655-3,481 across ICUs). The mean proportion of care periods with each quality metric varied between ICUs: excessive sedation 12-38%; agitation 4-17%; poor relaxation 13-21%; poor ventilator synchronization 8-17%; and overall optimum sedation 45-70%. Mean adverse event intervals ranged from 1.5 to 10.3 patients treated. The quality measures appeared relatively stable during the observation period. Conclusions: Process control methodology can be used to simultaneously monitor multiple aspects of pain-sedation-agitation management within ICUs. Variation within and between ICUs could be used as triggers to explore practice variation, improve quality, and monitor this over time

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To develop a structurally valid and reliable, yet brief measure of patient experience of hospital quality of care, the Care Experience Feedback Improvement Tool (CEFIT). Also, to examine aspects of utility of CEFIT. Background Measuring quality improvement at the clinical interface has become a necessary component of healthcare measurement and improvement plans, but the effectiveness of measuring such complexity is dependent on the purpose and utility of the instrument used. Methods CEFIT was designed from a theoretical model, derived from the literature and a content validity index (CVI) procedure. A telephone population surveyed 802 eligible participants (healthcare experience within the previous 12 months) to complete CEFIT. Internal consistency reliability was tested using Cronbach's α. Principal component analysis was conducted to examine the factor structure and determine structural validity. Quality criteria were applied to judge aspects of utility. Results CVI found a statistically significant proportion of agreement between patient and practitioner experts for CEFIT construction. 802 eligible participants answered the CEFIT questions. Cronbach's α coefficient for internal consistency indicated high reliability (0.78). Interitem (question) total correlations (0.28–0.73) were used to establish the final instrument. Principal component analysis identified one factor accounting for 57.3% variance. Quality critique rated CEFIT as fair for content validity, excellent for structural validity, good for cost, poor for acceptability and good for educational impact. Conclusions CEFIT offers a brief yet structurally sound measure of patient experience of quality of care. The briefness of the 5-item instrument arguably offers high utility in practice. Further studies are needed to explore the utility of CEFIT to provide a robust basis for feedback to local clinical teams and drive quality improvement in the provision of care experience for patients. Further development of aspects of utility is also required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This James Lind Alliance (JLA) Priority Setting Partnership aimed to identify and prioritise unanswered questions about adult intensive care that are important to people who have been critically ill, their families, and the health professionals who care for them. Consensus techniques (modified Delphi and Nominal Group) were used to generate suggestions using online and postal surveys. Following verification and iterative editorial review, research topics were constructed from these suggestions. These topics were presented in a second online and postal survey for rating. A Nominal Group of 21 clinicians, patients and family representatives subsequently met to rank the most important research topics and produce a prioritised list. The project was coordinated by a representative Steering Group and independently overseen by the JLA. The initial survey and review of the literature generated over 1,300 suggestions. Preliminary editing and verification permitted us to encapsulate these suggestions within 151 research topics. Iterative review by members of the Steering Group produced 37 topic statements, subsequently rated by participants. Using the mode to determine importance, 19 topics were presented to the group from which a ‘top three’ intensive care research priorities were identified and a further nine topics were prioritised. By applying and adapting the JLA methodology to focus on an area of care rather than to a single disease, we have provided a means to ensure that patients, their families and professionals materially contribute to the prioritisation of intensive care research in the UK.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: ‘Birth Satisfaction’ is a term that encompasses a woman’s evaluation of her birth experience. The term includes factors such as her appraisal of the quality of care she received, a personal assessment of how she coped, and her reconstructions of what happened on that particular day. Her accounts may be accurate or skewed, yet correspond with her reality of how events unfolded. Objective: To evaluate properties of an instrument designed to measure birth satisfaction in a Greek population of postnatal women. Study design: We assessed factor structure, internal consistency, divergent validity and known-groups discriminant validity of the 30-item Greek Birth Satisfaction Scale – Long Form (30-item G-BSS-LF) and its revised version the 10-item Greek-BSS-Revised (10-item-G-BSS-R), using survey data collected in Athens. Participants: A convenience sample of healthy Greek postnatal women (n = 162) aged 22–46 years who had delivered between 34 and 42 weeks’ gestation. Results: The 30-item-G-BSS-LF performed poorly in terms of factor structure. The short-form 10-item-G-BSS-R performed well in terms of measurement replication of the English equivalent version as a multidimensional instrument. The short-form 10-item-G-BSS-R comprises three subscales which measure distinct but correlated domains of: (1) quality of care provision (4 items), (2) women’s personal attributes (2 items), and (3) stress experienced during labour (4 items). Key conclusions: The 10-item-G-BSS-R is a valid and reliable multidimensional psychometric instrument for measuring birth satisfaction in Greek postnatal women.