3 resultados para OPTICAL PERFORMANCE MONITORING
em Repository Napier
Resumo:
The present methods for the detection of oil in discharge water are based either on chemical analysis of intermittent samples or bypass pipelines with instrumentation to detect either dissolved or dispersed hydrocarbons by a variety of optical techniques including absorption, scattering and fluorescence. However, test have shown that no single instruments entirely meets either present needs or satisfies the requirements of the future more stringent legislation which may limit total hydrocarbon content to 30 ppm or even less. Hence, in this paper, a detector is devised which can detect both dissolved and dispersed oil products, has a high immunity to scattering and can operate in-line and harsh environments with a detection sensitivity of a few ppm throughout a wide range of operations.
Resumo:
There is increasing evidence of a causal link between airborne particles and ill health and this study monitored the exposure to both airborne particles and the gas phase contaminants of environmental tobacco smoke (ETS) in a nightclub. The present study followed a number of pilot studies in which the human exposure to airborne particles in a nightclub was assessed and the spatio-temporal distribution of gas phase pollutants was evaluated in restaurants and pubs. The work reported here re-examined the nightclub environment and utilized concurrent and continuous monitoring using optical scattering samplers to measure particulates (PM10) together with multi-gas analysers. The analysis illustrated the highly episodic nature of both gaseous and particulate concentrations in both the dance floor and in the bar area but levels were well below the maximum recommended exposure levels. Short-term exposure to high concentrations may however be relevant when considering the possible toxic effects on biological systems. The results give an indication of the problems associated with achieving acceptable indoor air quality (IAQ) in a complex space and identified some of the problems inherent in the design and operation of ventilation systems for such spaces.
Resumo:
Background. Excessive sedation is associated with adverse patient outcomes during critical illness, and a validated monitoring technology could improve care. We developed a novel method, the responsiveness index (RI) of the frontal EMG. We compared RI data with Ramsay clinical sedation assessments in general and cardiac intensive care unit (ICU) patients. Methods. We developed the algorithm by iterative analysis of detailed observational data in 30 medical–surgical ICU patients and described its performance in this cohort and 15 patients recovering from scheduled cardiac surgery. Continuous EMG data were collected via frontal electrodes and RI data compared with modified Ramsay sedation state assessments recorded regularly by a blinded trained observer. RI performance was compared with EntropyTM across Ramsay categories to assess validity. Results. RI correlated well with the Ramsay category, especially for the cardiac surgery cohort (general ICU patients r¼0.55; cardiac surgery patients r¼0.85, both P,0.0001). Discrimination across all Ramsay categories was reasonable in the general ICU patient cohort [PK¼0.74 (SEM 0.02)] and excellent in the cardiac surgery cohort [PK¼0.92 (0.02)]. Discrimination between ‘lighter’ vs ‘deeper’ (Ramsay 1–3 vs 4–6) was good for general ICU patients [PK¼0.80 (0.02)] and excellent for cardiac surgery patients [PK¼0.96 (0.02)]. Performance was significantly better than EntropyTM. Examination of individual cases suggested good face validity. Conclusions. RI of the frontal EMG has promise as a continuous sedation state monitor in critically ill patients. Further investigation to determine its utility in ICU decision-making is warranted.