3 resultados para analytical methods

em Repositorio Institucional da UFLA (RIUFLA)


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Procymidone, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to apple crops. In this work, we propose a reliable and sensitive method to determine procymidone in Brazilian apples. The method involves differential pulse (DPV) and square-wave voltammetry (SWV) techniques on a glassy carbon electrode. In a supporting electrolyte solution of 0.5 mol L−1 NaOH, procymidone undergoes an irreversible one-electron oxidation at +1.42 V by cyclic voltammetric vs. Ag|AgCl, KCl 3 M reference electrode. The proposed DPV and SWV methods have a good linear response in the 8.00–20.0 mg L−1 range, with limits of detection (LOD) of 0.678 and 0.228 mg L−1, respectively, in the absence of the matrix. We obtained improved LOD (0.097 mg L−1) in the presence of apple matrix and the supporting electrolyte solution. We used three commercial apple samples to evaluate recovery, and we achieved recovery percentages ranging from 94.6 to 110 % for procymidone determinations. We also tested the proposed voltammetric method for reproducibility, repeatability, and potential interferents, and the results were satisfactory for electroanalytical purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present study aimed to characterize and quantify four contaminants (ethyl carbamate, 2,3-butanedione, furfural and 5-hydroxymethylfurfural) present in alembic cachaça and industrial. Were collected forty-four samples of cachaça in the southern regions, the Midwest, southeast of Minas Gerais and São Paulo state, and subsequently subjected to physical, chemical and chromatographic analyzes. The physicochemical analyzes were performed according to the methodology described by the Ministry of Agriculture, Livestock and Supply (MAPA). The ethyl carbamate, 2,3-butanedione, furfuaral and 5 hydroxymethylfurfural were characterized and quantified by high-performance liquid chromatography (HPLC). The results of the ethyl carbamate analysis, it was found that both samples showed column cachaças outside the standards required by law, with the values 245.31 235.53 L-1 ug and none of the liquor samples alembic showed concentration greater than 210.0 ug L-1 , and the method is very sensitive to low limits of detection and quantification. In determining 2,3-butanedione, it was revealed that the column cachaças showed higher levels of contaminants when compared to cachaça alembic. In the quantification of furfural and 5-hydroxymethylfurfural was developed and validated analytical methods employed to high-performance liquid chromatography (HPLC) with DAD detector. Samples column cachaças showed higher values than the limit established by Brazilian legislation and ranged from 7.00 to 5.63 mg / 100 ml of anhydrous alcohol over the alembic cachaça.