3 resultados para High Performance liquid chromatography coupled with mass spectrometry (LC-MS)
em Repositorio Institucional da UFLA (RIUFLA)
Resumo:
In the present study aimed to characterize and quantify four contaminants (ethyl carbamate, 2,3-butanedione, furfural and 5-hydroxymethylfurfural) present in alembic cachaça and industrial. Were collected forty-four samples of cachaça in the southern regions, the Midwest, southeast of Minas Gerais and São Paulo state, and subsequently subjected to physical, chemical and chromatographic analyzes. The physicochemical analyzes were performed according to the methodology described by the Ministry of Agriculture, Livestock and Supply (MAPA). The ethyl carbamate, 2,3-butanedione, furfuaral and 5 hydroxymethylfurfural were characterized and quantified by high-performance liquid chromatography (HPLC). The results of the ethyl carbamate analysis, it was found that both samples showed column cachaças outside the standards required by law, with the values 245.31 235.53 L-1 ug and none of the liquor samples alembic showed concentration greater than 210.0 ug L-1 , and the method is very sensitive to low limits of detection and quantification. In determining 2,3-butanedione, it was revealed that the column cachaças showed higher levels of contaminants when compared to cachaça alembic. In the quantification of furfural and 5-hydroxymethylfurfural was developed and validated analytical methods employed to high-performance liquid chromatography (HPLC) with DAD detector. Samples column cachaças showed higher values than the limit established by Brazilian legislation and ranged from 7.00 to 5.63 mg / 100 ml of anhydrous alcohol over the alembic cachaça.
Resumo:
The HPLC technique with UV-Vis detection was employed in the analysis of cocaine content in apprehended samples of cocaine and crack. A peak signal for cocaine was obtained in 3.5 minutes run by using acetonitrile/water (95:5v/v) as a mobile phase. Optimized spectrophotometric signal was obtained at a wavelength of 224 nm. The analytical curve from 1.0 to 40.0 ppm of cocaine was obtained, showing a linear correlation coefficient of 0.9989, with detection and quantification limits of 0.75 ppm and 3.78 ppm, respectively. This methodology was employed at the dosage of confiscated samples of cocaine and crack in the Scientific Police Laboratory of Ribeirão Preto-SP city.
Resumo:
Cachaça is a distiled beverage obtained from the fermentation of sugar cane syrup that, depending on the production procedures, may be susceptible to contamination by polycyclic aromatic hydrocarbons (PAHs). These compounds present carcinogenic and/or mutagenic properties and offer a risk to human health. Sixteen PAHs were determined in cachaças that had been stored in glass bottles and in polyethylene tank by gas chromatography coupled with mass spectrometry. The quantification of the PAHs utilised an internal standard. The limits of detection and quantification varied from 0.05 to 0.10 μg L−1 and 0.20 to 0.30 μg L−1, respectively. A total PAH concentration of 51.57 μg L−1 was found in the beverages that were stored in the tank, while the concentration in the cachaça stored in glass jugs was 6.07 μg L−1. These results indicate that the polyethylene tank is a source for PAHs in cachaça.