2 resultados para Eficiência do nitrogênio
em Repositorio Institucional da UFLA (RIUFLA)
Resumo:
Nitrogen (N) is the most required nutrient for corn plants and, in order to supply this demand in highly productive crops, mineral fertilizers are used, especially urea. The disadvantage of urea is the loss of N-NH3 to atmosphere. To reverse this situation, some technologies have been developed, such as nitrification and urease inhibitors, which are used as additives to urea. This work aimed at evaluating the agronomic efficiency of urea stabilized with urease and nitrification inhibitors applied to cover the 2013/2014 corn crop. We evaluated 11 nitrogen fertilizer applied in coverage: urea + PA (41.6% N, 3% Cu); urea + PA (41.6% N, 1.5% Cu); urea + PA (41.6% N, 3% Zn); urea + PA (41.6% N, 1.5% Zn); urea + PA (41.6% N, 0.34% Cu, 0.94% B); urea + PA (41.6% N, 0.25% Cu, 0.68% B); urea + PA (41.6% N); urea (44.3% N, 0.15% Cu, 0.4% B); urea (43% N, 0.1% Cu, 0.3% B, 0.05% Mo); pearled urea (46% N); urea + 0,8% DMPP (45% N) and the control, which did not receive nitrogen topdressing. The evaluations were: Nitrogen losses through volatilization, content and accumulation of N, boron (B), copper (Cu) and zinc (Zn) to the dry matter of aerial parts, grains, and in straw and grain productivity. Fertilizers stabilized with urease and nitrification inhibitors did not reduce the volatilization of ammonia volatilization, when compared to pearled urea. Urea with 0.8% of DMPP nitrification inhibitor (3,4-dimethylpyrazole phosphate) provided higher loss by volatilization, lower productivity and agronomic efficiency compared to pearled urea. The coating of urea with Cu, B and Zn did not increase the accumulation of these nutrients in grains and MSPA plants. The use of fertilizers stabilized and coated with micronutrients did not increase the productivity and agronomic efficiency compared to conventional urea.
Resumo:
The HPLC technique with UV-Vis detection was employed in the analysis of cocaine content in apprehended samples of cocaine and crack. A peak signal for cocaine was obtained in 3.5 minutes run by using acetonitrile/water (95:5v/v) as a mobile phase. Optimized spectrophotometric signal was obtained at a wavelength of 224 nm. The analytical curve from 1.0 to 40.0 ppm of cocaine was obtained, showing a linear correlation coefficient of 0.9989, with detection and quantification limits of 0.75 ppm and 3.78 ppm, respectively. This methodology was employed at the dosage of confiscated samples of cocaine and crack in the Scientific Police Laboratory of Ribeirão Preto-SP city.