3 resultados para ELECTROANALYTICAL DETERMINATION
em Repositorio Institucional da UFLA (RIUFLA)
Resumo:
Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five–electron transfer vs. Ag|AgCl, KCl 3 M reference electrode. Very well–resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L−1 at −1.43, −1.57, −1.73, −1.88, and −2.05 V. The proposed DPV method has a good linear response in the 3.00 – 10.0 μmol L−1 range, with a limit of detection (L.O.D) of 0.756 μmol L−1 and 0.831 μmol L−1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 μmol L−1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes.
Resumo:
The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaça) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L - 1 for lead and copper. The limits of detection were 48.5 and 23.9 µg L - 1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.
Resumo:
Procymidone, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to apple crops. In this work, we propose a reliable and sensitive method to determine procymidone in Brazilian apples. The method involves differential pulse (DPV) and square-wave voltammetry (SWV) techniques on a glassy carbon electrode. In a supporting electrolyte solution of 0.5 mol L−1 NaOH, procymidone undergoes an irreversible one-electron oxidation at +1.42 V by cyclic voltammetric vs. Ag|AgCl, KCl 3 M reference electrode. The proposed DPV and SWV methods have a good linear response in the 8.00–20.0 mg L−1 range, with limits of detection (LOD) of 0.678 and 0.228 mg L−1, respectively, in the absence of the matrix. We obtained improved LOD (0.097 mg L−1) in the presence of apple matrix and the supporting electrolyte solution. We used three commercial apple samples to evaluate recovery, and we achieved recovery percentages ranging from 94.6 to 110 % for procymidone determinations. We also tested the proposed voltammetric method for reproducibility, repeatability, and potential interferents, and the results were satisfactory for electroanalytical purposes.