27 resultados para waste water treatment
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This study reports the performance of a combined anaerobic-aerobic packed-bed reactor that can be used to treat domestic sewage. Initially, a bench-scale reactor was operated in three experimental phases. In the first phase, the anaerobic reactor was operated with an average organic matter removal efficiency of 77% for a hydraulic retention time (HRT) of 10 h. In the second phase, the reactor was operated with an anaerobic stage followed by an aerobic zone, resulting in a mean value of 91% efficiency. In the third and final phase, the anaerobic-aerobic reactor was operated with recirculation of the effluent of the reactor through the anaerobic zone. The system yielded mean total nitrogen removal percentages of 65 and 75% for recycle ratios (r) of 0.5 and 1.5, respectively, and the chemical oxygen demand (COD) removal efficiencies were higher than 90%. When the pilot-scale reactor was operated with an HRT of 12 h and r values of 1.5 and 3.0, its performance was similar to that observed in the bench-scale unit (92% COD removal for r = 3.0). However, the nitrogen removal was lower (55% N removal for r = 3.0) due to problems with the hydrodynamics in the aerobic zone. The anaerobic-aerobic fixed-bed reactor with recirculation of the liquid phase allows for concomitant carbon and nitrogen removal without adding an exogenous source of electron donors and without requiring any additional alkalinity supplementation.
Resumo:
Solar reactors can be attractive in photodegradation processes due to lower electrical energy demand. The performance of a solar reactor for two flow configurations, i.e., plug flow and mixed flow, is compared based on experimental results with a pilot-scale solar reactor. Aqueous solutions of phenol were used as a model for industrial wastewater containing organic contaminants. Batch experiments were carried out under clear sky, resulting in removal rates in the range of 96100?%. The dissolved organic carbon removal rate was simulated by an empirical model based on neural networks, which was adjusted to the experimental data, resulting in a correlation coefficient of 0.9856. This approach enabled to estimate effects of process variables which could not be evaluated from the experiments. Simulations with different reactor configurations indicated relevant aspects for the design of solar reactors.
Resumo:
This work aimed to evaluate the influence of specific operational conditions on the performance of a spiral-wound ultrafiltration pilot plant for direct drinking water treatment, installed at the Guarapiranga's reservoir, in the Sao Paulo Metropolitan Region. Results from operational tests showed that the volume of permeate produced in the combination of periodic relaxation with flushing and chlorine dosage procedures was 49% higher than the volume obtained when these procedures were not used. Two years of continuous operation demonstrated that the ultrafiltration pilot plant performed better during fall and winter seasons, higher permeate flow production and reduced chemical cleanings frequency. Observed behavior seems to be associated with the algae bloom events in the reservoir, which are more frequent during spring and summer seasons, confirmed by chlorophyll-a analysis results. Concentrate clarification using ferric chloride was quite effective in removing NOM and turbidity, allowing its recirculation to the ultrafiltration feed tank. This procedure made it possible to reach almost 99% water recovery considering a single 54-hour recirculation cycle. Water quality monitoring demonstrated that the ultrafiltration pilot plant was quite efficient, and that potential pathogenic organisms, Escherichia coil and total coliforms, turbidity and apparent color removals were 100%, 95.1%, and 91.5%, respectively. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Hydrogen peroxide is a powerful oxidant that finds application in several areas, but most particularly in the treatment of industrial wastewaters. The aim of the present study was to investigate the effects of applied potential and electrolyte flow conditions on the in situ generation of hydrogen peroxide in an electrochemical flow-by reactor with a gas diffusion electrode (GDE). The electrolyses were performed in an aqueous acidic medium using a GDE constructed with conductive black graphite and polytetrafluoroethylene (80:20 w/w). Under laminar flow conditions (flow rate = 50 L/h), hydrogen peroxide was formed in a maximum yield of 414 mg/L after 2 h at -2.25 V vs Pt //Ag/AgCl (global rate constant = 3.1 mg/(L min); energy consumption = 22.1 kWh/kg). Under turbulent flow (300 L/h), the maximum yield obtained was 294 mg/L after 2 h at -1.75 V vs Pt//Ag/AgCl (global rate constant = 2.5 mg/ (L min); energy consumption = 30.1 kWh/kg).
Resumo:
This report shows an unexpected toxicity decrease during atrazine photoelectrodegradation in the presence of NaCl. Atrazine is a pesticide classified as endocrine disruptor occurring in industrial effluents and agricultural wastewaters. We therefore studied the effects of the degradation method, electrochemical and electrochemical photo-assisted, and of the supporting electrolyte, NaCl and Na2SO4, on the residual toxicity of treated atrazine solutions. We also studied the toxicity of treated atrazine solutions using Results show that at initial concentration of 20 mg L-1, atrazine was completely removed in up to 30 min using 10 mA cm(-2) electrolysis in NaCl medium, regardless of the electrochemical method used. The total organic carbon removal by the photo-assisted method was 82% with NaCl and 95% with Na2SO4. The solution toxicity increased during sole electrochemical treatment in NaCl, as expected. However, the toxicity unexpectedly decreased using the photo-assisted method. This finding is a major discovery because electrochemical treatment with NaCl usually leads to the formation of toxic chlorine-containing organic degradation by-products.
Resumo:
DEVELOPMENT AND EVALUATION OF GAS DIFFUSION ELECTRODES (GDE) FOR GENERATION OF H2O2 IN SITU AND THEIR APPLICATION IN THE DEGRADATION OF REACTIVE BLUE 19 DYE. This work reports the development of GDE for electrogeneration of H2O2 and their application in the degradation process of Reactive Blue 19 dye. GDE produced by carbon black with 20% polytetrafluoroethylene generated up to 500 mg L-1 of H2O2 through the electrolysis of acidic medium at -0.8 V vs Ag/AgCl. Reactive Blue 19 dye was degraded most efficiently with H2O2 electrogenerated in the presence of Fe(II) ions, leading to removal of 95% of the original color and 39% of TOC at -0.8 V vs Ag/AgCl.
Resumo:
The objective of this research was to study phenol degradation in anaerobic fluidized bed reactors (AFBR) packed with polymeric particulate supports (polystyrene - PS, polyethylene terephthalate - PET, and polyvinyl chloride - PVC). The reactors were operated with a hydraulic retention time (HRT) of 24 h. The influent phenol concentration in the AFBR varied from 100 to 400 mg L-1, resulting in phenol removal efficiencies of similar to 100%. The formation of extracellular polymeric substances yielded better results with the PVC particles; however, deformations in these particles proved detrimental to reactor operation. PS was found to be the best support for biomass attachment in an AFBR for phenol removal. The AFBR loaded with PS was operated to analyze the performance and stability for phenol removal at feed concentrations ranging from 50 to 500 mg L-1. The phenol removal efficiency ranged from 90-100%.
Resumo:
The chemical stock of emerging contaminants in Brazilian drinking water is of great interest due to the poor water quality at surface water intakes. In addition, little is known about the effect of some contaminants, such as endocrine disrupting chemicals (EDCs), which may be present in both raw and treated water. The aim of this work was to evaluate selected emerging contaminants in Brazilian waters using both chemical and biological analyses. Sampling sites were established in different municipalities based upon raw water quality data. Estrone, 17 beta-estradiol, estriol, 17 alpha-ethinylestradiol, bisphenol A, 4-n-octylphenol and 4-n-nonylphenol were determined in the samples by liquid chromatography-tandem mass spectrometry. A yeast assay using a Saccharomyces cerevisiae bioluminescent bioreporter was used to evaluate the estrogenic activity of the water samples. The first integrated results revealed similarities between the two individual approaches, since higher values for the bioassay were accompanied by significant concentrations of some selected compounds in surface water samples. No estrogenicity was observed for drinking water samples. Our results also indicate that the usual paradigm of evaluating water quality by measuring selected EDCs in a given water sample via chemical analysis, needs to be reviewed since the observed estrogenicity of a water sample is now a better guiding parameter to the selection of samples and substances to be chemically investigated in further analysis. So far, the data bank produced in this work, i.e., the comparison between chemical burden and observed estrogenicity, is not yet sufficiently robust to fully guide this decision. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min(-1) for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H2O2 concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this work, the effect of various casting solution salt dopants with similar cations, but different anions: (NaPO3)(6), Na2SO4, Na2CO3, NaCl, and NaF, on the morphology and performance of polyethersulfone ultrafiltration membranes was evaluated. The phase inversion process was used to produce all membranes using an 18% polyethersulfone in n-methylpyrrolidone casting solution and water as the non-solvent. Scanning electron microscopy (SEM) images of the membrane cross-section and surface pores were used to determine the specific anion effects on membrane morphology. The SEM images depicted significant changes to the membrane internal structure and pore size with respect to the type and concentration of the casting solution anion dopant. Membrane permeability, molecular weight cut-off, alginate retention, and susceptibility to fouling were evaluated using ultrapure water dead-end and ultrapure water, aqueous polyethylene glycol, aqueous sodium alginate, and natural surface water cross-flow filtration tests. Among the anions evaluated, hexametaphosphate doped at 1% w/w to the polymer resulted in the membrane with highest dead-end permeability at 490 LMH-bar (2- to 3-fold greater than the control), greatest alginate retention at 96.5%, and lowest susceptibility to fouling. The significant increase in membrane performance indicates that the hexametaphosphate anion has great potential to be used as a membrane casting solution dopant. It was also clearly demonstrated that membrane pore morphological characteristics can be effectively used to predict drinking water treatment performance. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
O objetivo deste trabalho foi quantificar o aporte e a remoção de nutrientes em sistemas de cultivo de cana‑de‑açúcar irrigados, ou não, com efluente de estação de tratamento de esgoto (EETE), com e sem adição de fosfogesso, bem como avaliar os efeitos desses sistemas de cultivo no estado nutricional das plantas. Foram avaliados tratamentos sem irrigação e com irrigação a 100 e 150% da necessidade hídrica da cultura. Os tratamentos com fosfogesso foram aplicados em área de terceiro corte, irrigada com EETE desde o plantio. As avaliações foram realizadas em duas safras. Os tratamentos não afetaram os rendimentos de colmos. O tratamento com EETE e fosfogesso apresentou efeito sinérgico sobre o conteúdo de nitrogênio e de enxofre nas plantas. O EETE beneficiou a nutrição das plantas quanto ao fósforo, mas não causou melhorias na nutrição com potássio e enxofre. A nutrição com ferro, zinco e manganês não foi influenciada pelo aporte desses micronutrientes pelo EETE. O fósforo e o nitrogênio aportados na irrigação com EETE devem ser considerados na recomendação de adubação. Porém, potássio, enxofre, ferro, zinco e manganês do efluente não são fontes eficientes desses nutrientes para as plantas.
Resumo:
2-Methylisoborneol (MIB) and geosmin (GSM) are sub products from algae decomposition and, depending on their concentration, can be toxic: otherwise, they give unpleasant taste and odor to water. For water treatment companies it is important to constantly monitor their presence in the distributed water and avoid further costumer complaints. Lower-cost and easy-to-read instrumentation would be very promising in this regard. In this study, we evaluate the potentiality of an electronic tongue (ET) system based on non-specific polymeric sensors and impedance measurements in monitoring MIB and GSM in water samples. Principal component analysis (PCA) applied to the generated data matrix indicated that this ET was capable to perform with remarkable reproducibility the discrimination of these two contaminants in either distilled or tap water, in concentrations as low as 25 ng L-1. Nonetheless, this analysis methodology was rather qualitative and laborious, and the outputs it provided were greatly subjective. Also, data analysis based on PCA severely restricts automation of the measuring system or its use by non-specialized operators. To circumvent these drawbacks, a fuzzy controller was designed to quantitatively perform sample classification while providing outputs in simpler data charts. For instance, the ET along with the referred fuzzy controller performed with a 100% hit rate the quantification of MIB and GSM samples in distilled and tap water. The hit rate could be read directly from the plot. The lower cost of these polymeric sensors allied to the especial features of the fuzzy controller (easiness on programming and numerical outputs) provided initial requirements for developing an automated ET system to monitor odorant species in water production and distribution. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In a field experiment performed in Lins County (Sao Paulo State, Brazil), treated sewage effluent (TSE) irrigation increased sugarcane yield but caused an excessive increase in the exchangeable sodium percentage (ESP) and clay dispersion after 16 months due to an intense irrigation regime (2500 mm/16 months) with sodium rich effluents. After two additional complete cycles with lower TSE irrigation rates (1200 mm year(-1)), 1700 kg ha(-1) of phosphogypsum was added to a section of the irrigated plots to evaluate its residence time and its implications on Na+ dynamics and other soil properties. Undisturbed soil cores were taken 2 years after phosphogypsum application to verify soil physical properties up to 0.2 m depth, and disturbed soil samples were taken every year up to 1 m depth for chemical analyses. After 5 years of consecutive TSE irrigation (2005-2010), soil acidity (pH approximate to 5) and basic cations (Ca approximate to 12, Mg approximate to 6 and K approximate to 2 mmol(c) kg(-1)) were maintained in adequate conditions for plant development without the necessity of liming, while acidity was increased (pH approximate to 4.5) and Ca (approximate to 9 mmol(c) kg(-1)), and the Mg (approximate to 4.5 mmol(c) kg(-1)) concentration decreased in the rainfed without phosphogypsum treatment. An increase in water retention capacity at -30 (from 0.14 to 0.17 m(3) m(-3)) and -1500 kPa (from 0.08 to 0.12 m(3) m(-3)) potentials was also observed in all TSE irrigated treatments. The plots with a phosphogypsum treatment showed average increases of 2 mmol(c) kg(-1) of Ca2+ and 7 mg kg(-1) of S-SO42- in all soil profiles and an average reduction of 2 mmol(c) kg(-1) of Na+ up to 0.4 m from 2008 to 2009. However, the extent of the chemical effects was greater after the first year compared to the second year. The high concentration of Na+ found in previous studies performed in the same area returned to low concentrations after continued TSE irrigation at lower rates, even without the phosphogypsum application. An unusual phosphorus migration was observed to the 0.4-0.8 m soil layer as a result of TSE irrigation, most likely due to a high pH and a Na carbonate-dominated TSE. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
A comparative study using different proportions of CeO2/C (4%, 9% and 13% CeO2) was performed to produce H2O2, a reagent used in the oxidation of organic pollutants and in electro-Fenton reactions for the production of the hydroxyl radical (OH center dot), a strong oxidant agent used in the electrochemical treatment of aqueous wastewater. The CeO2/C materials were prepared by a modified polymeric precursor method (PPM). X-ray diffraction analysis of the CeO2/C prepared by the PPM identified two phases. CeO2 and CeO2. The average size of the crystallites in these materials was close to 7 nm. The kinetics of the oxygen reduction reaction (ORR) were evaluated by the rotating ring-disk electrode technique. The results showed that the 4% CeO2/C prepared by the PPM was the best composite for the production of H2O2 in a 1 mol L-1 NaOH electrolyte solution. For this material, the number of electrons transferred and the H2O2 percentage efficiency were 3.1 and 44%, respectively. The ring-current of the 4% CeO2/C was higher than that of Vulcan carbon, the reference material for H2O2 production, which produced 41% H2O2 and transferred 3.1 electrons per molecule of oxygen. The overpotential for this reaction on the ceria-based catalyst was substantially lower (approximately 200 mV), demonstrating the higher catalytic performance of this material. Gas diffusion electrodes (GDE) containing the catalyst were used to evaluate the real amount of H2O2 produced during exhaustive electrolysis. The 4% CeO2/C GDE produced 871 mg L-1 of H2O2, whereas the Vulcan carbon GDE produced a maximum amount of only 407 mg L-1. Thus, the 4% CeO2/C electrocatalyst prepared by the PPM is a promising material for H2O2 electrogeneration in alkaline media. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Fluoridation of the public water supplies is recognized as among the top ten public health achievements of the twentieth century. However, the positive aspects of this measure depend on the maintenance of fluoride concentrations within adequate levels. To report the results of seven years of external control of the fluoride (F) concentrations in the public water supply in Bauru, SP, Brazil in an attempt to verify, on the basis of risk/benefit balance, whether the levels are appropriate. From March 2004 to February 2011, 60 samples were collected every month from the 19 supply sectors of the city, totaling 4,641 samples. F concentrations in water samples were determined in duplicate, using an ion-specific electrode (Orion 9609) coupled to a potentiometer after buffering with TISAB II. After the analysis, the samples were classified according to the best risk-benefit adjustment. Means (±standard deviation) of F concentrations ranged between 0.73±0.06 and 0.81±0.10 mg/L for the different sectors during the seven years. The individual values ranged between 0.03 and 2.63 mg/L. The percentages of the samples considered “low risk” for dental fluorosis development and of “maximum benefit” for dental caries prevention (0.55-0.84 mg F/L) in the first, second, third, fourth, fifth, sixth, and seventh years of the study were 82.0, 58.5, 37.4, 61.0, 89.9, 77.3, and 72.4%, respectively, and 69.0% for the entire period. Fluctuations of F levels were found in the public water supply in Bauru during the seven years of evaluation. These results suggest that external monitoring of water fluoridation by an independent assessor should be implemented in cities where there is adjusted fluoridation. This measure should be continued in order to verify that fluoride levels are suitable and, if not, to provide support for the appropriate adjustments