4 resultados para visual development
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Background: This study measured grating visual acuity in 173 children between 6-48 months of age who had different types of spastic cerebral palsy (CP). Method: Behavioural acuity was measured with the Teller Acuity Cards (TAC) using a staircase psychophysical procedure. Electrophysiological visual acuity was estimated using the sweep VEP (sVEP). Results: The percentage of children outside the superior tolerance limits was 44 of 63 (69%) and 50 of 55 (91%) of tetraplegic, 36 of 56 (64%) and 42 of 53 (79%) of diplegic, 10 of 48 (21%) and 12 of 40 (30%) of hemiplegic for sVEP and TAC, respectively. For the sVEP, the greater visual acuity deficit found in the tetraplegic group was significantly different from that of the hemiplegic group (p < 0.001). In the TAC procedure the mean visual acuity deficits of the tetraplegic and diplegic groups were significantly different from that of hemiplegic group (p < 0.001). The differences between sVEP and TAC means of visual acuity difference were statistically significant for the tetraplegic (p < 0.001), diplegic (p < 0.001), and hemiplegic group (p = 0.004). Discussion: Better visual acuities were obtained in both procedures for hemiplegic children compared to diplegic or tetraplegic. Tetraplegic and diplegic children showed greater discrepancies between the TAC and sVEP results. Inter-ocular acuity difference was more frequent in sVEP measurements. Conclusions: Electrophysiologically measured visual acuity is better than behavioural visual acuity in children with CP.
Resumo:
The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target Stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees Of Visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment I Sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects` performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data-including those obtained for children-fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.
Thyroid hormone action is required for normal cone opsin expression during mouse retinal development
Resumo:
PURPOSE. The expression of S- and M-opsins in the murine retina is altered in different transgenic mouse models with mutations in the thyroid hormone receptor (TR)-beta gene, demonstrating an important role of thyroid hormone (TH) in retinal development. METHODS. The spatial expression of S- and M-opsin was compared in congenital hypothyroidism and in two different TR mutant mouse models. One mouse model contains a ligand-binding mutation that abolishes TH binding and results in constitutive binding to nuclear corepressors. The second model contains a mutation that blocks binding of coactivators to the AF-2 domain without affecting TH binding. RESULTS. Hypothyroid newborn mice showed an increase in S- opsin expression that was completely independent of the genotype. Concerning M-opsin expression, hypothyroidism caused a significant decrease (P < 0.01) only in wild-type animals. When TR beta 1 and -beta 2 were T3-binding defective, the pattern of opsin expression was similar to TR beta ablation, showing increased S- opsin expression in the dorsal retina and no expression of M-opsin in the entire retina. In an unexpected finding, immunostaining for both opsins was detected when both subtypes of TR beta were mutated in the helix 12 AF-2 domain. CONCLUSIONS. The results show, for the first time, that the expression of S- and M-opsin is dependent on normal thyroid hormone levels during development.
Resumo:
Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.