6 resultados para time-kill curve

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: We present a prospective study of a microemulsion of cyclosporin to treat idiopathic nephrotic syndrome in ten children with normal renal function who presented cyclosporin trough levels between 50 and 150 ng/ml and achieved complete remission with cyclosporin. To compare the pharmacokinetic parameters of cyclosporin in idiopathic nephrotic syndrome during remission and relapse of the nephrotic state. METHOD: The pharmacokinetic profile of cyclosporin was evaluated with the 12-hour area under the time-concentration curve (auc0-12) using seven time-point samples. This procedure was performed on each patient during remission and relapse with the same cyclosporin dose in mg/kg/day. The 12-hour area under the time-concentration curve was calculated using the trapezoidal rule. All of the pharmacokinetic parameters and the resumed 4-hour area under the time-concentration curve were correlated with the 12-hour area under the time-concentration curve. ClinicalTrials.gov: NCT01616446. RESULTS: There were no significant differences in any parameters of the pharmacokinetic of cyclosporin during remission and relapse, even when the data were normalized by dose. The best correlation with the 12-hour area under the time-concentration curve was the 4-hour area under the time-concentration curve on remission and relapse of the disease, followed by the 2-hour level after cyclosporin (c2) dosing in both disease states. CONCLUSIONS: These data indicate that the same parameters used for cyclosporin therapeutic monitoring estimated during the nephrotic state can also be used during remission. Larger controlled studies are needed to confirm these findings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: We present a prospective study of a microemulsion of cyclosporin to treat idiopathic nephrotic syndrome in ten children with normal renal function who presented cyclosporin trough levels between 50 and 150 ng/ml and achieved complete remission with cyclosporin. To compare the pharmacokinetic parameters of cyclosporin in idiopathic nephrotic syndrome during remission and relapse of the nephrotic state. METHOD: The pharmacokinetic profile of cyclosporin was evaluated with the 12-hour area under the timeconcentration curve (auc0-12) using seven time-point samples. This procedure was performed on each patient during remission and relapse with the same cyclosporin dose in mg/kg/day. The 12-hour area under the timeconcentration curve was calculated using the trapezoidal rule. All of the pharmacokinetic parameters and the resumed 4-hour area under the time-concentration curve were correlated with the 12-hour area under the timeconcentration curve. ClinicalTrials.gov:NCT01616446. RESULTS: There were no significant differences in any parameters of the pharmacokinetic of cyclosporin during remission and relapse, even when the data were normalized by dose. The best correlation with the 12-hour area under the time-concentration curve was the 4-hour area under the time-concentration curve on remission and relapse of the disease, followed by the 2-hour level after cyclosporin (c2) dosing in both disease states. CONCLUSIONS: These data indicate that the same parameters used for cyclosporin therapeutic monitoring estimated during the nephrotic state can also be used during remission. Larger controlled studies are needed to confirm these findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work quantifies, using ADP and rating curve techniques, the instantaneous outflows at estuarine interfaces: higher to middle estuary and middle to lower estuary, in two medium-sized watersheds (72 000 and 66 000 km(2) of area, respectively), the Jaguaribe and Contas Rivers located in the northeastern (semi-arid) and eastern (tropical humid) Brazilian coasts, respectively. Results from ADP showed that the net water balances show the Contas River as a net water exporter, whereas the Jaguaribe River Estuary is a net water importer. At the Jaguaribe Estuary, water retention during flood tide contributes to 58% of the total volume transferred during the ebb tide from the middle to lower estuary. However, 42% of the total water volume (452 m(3) s(-1)) that entered during flood tide is retained in the middle estuary. In the Contas River, 90% of the total water is retained during the flood tide contributing to the volume transported in the ebb tide from the middle to the lower estuary. Outflows obtained with the rating curve method for the Contas and Jaguaribe Rivers were uniform through time due to river flow normalization by dams in both basins. Estimated outflows with this method are about 65% (Contas) and 95% (Jaguaribe) lower compared to outflows obtained with ADP. This suggests that the outflows obtained with the rating curve method underestimate the net water balance in both systems, particularly in the Jaguaribe River under a semi-arid climate. This underestimation is somewhat decreased due to wetter conditions in the Contas River basin. Copyright. (C) 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The theoretical E-curve for the laminar flow of non-Newtonian fluids in circular tubes may not be accurate for real tubular systems with diffusion, mechanical vibration, wall roughness, pipe fittings, curves, coils, or corrugated walls. Deviations from the idealized laminar flow reactor (LFR) cannot be well represented using the axial dispersion or the tanks-in-series models of residence time distribution (RTD). In this work, four RTD models derived from non-ideal velocity profiles in segregated tube flow are proposed. They were used to represent the RTD of three tubular systems working with Newtonian and pseudoplastic fluids. Other RTD models were considered for comparison. The proposed models provided good adjustments, and it was possible to determine the active volumes. It is expected that these models can be useful for the analysis of LFR or for the evaluation of continuous thermal processing of viscous foods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The extraction of information about neural activity timing from BOLD signal is a challenging task as the shape of the BOLD curve does not directly reflect the temporal characteristics of electrical activity of neurons. In this work, we introduce the concept of neural processing time (NPT) as a parameter of the biophysical model of the hemodynamic response function (HRF). Through this new concept we aim to infer more accurately the duration of neuronal response from the highly nonlinear BOLD effect. The face validity and applicability of the concept of NPT are evaluated through simulations and analysis of experimental time series. The results of both simulation and application were compared with summary measures of HRF shape. The experiment that was analyzed consisted of a decision-making paradigm with simultaneous emotional distracters. We hypothesize that the NPT in primary sensory areas, like the fusiform gyrus, is approximately the stimulus presentation duration. On the other hand, in areas related to processing of an emotional distracter, the NPT should depend on the experimental condition. As predicted, the NPT in fusiform gyrus is close to the stimulus duration and the NPT in dorsal anterior cingulate gyrus depends on the presence of an emotional distracter. Interestingly, the NPT in right but not left dorsal lateral prefrontal cortex depends on the stimulus emotional content. The summary measures of HRF obtained by a standard approach did not detect the variations observed in the NPT. Hum Brain Mapp, 2012. (C) 2010 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The expression of glucocorticoid-receptor (GR) seems to be a key mechanism in the regulation of glucocorticoid (GC) sensitivity and is potentially involved in cases of GC resistance or hypersensitivity. The aim of this study is to describe a method for quantitation of GR alpha isoform (GRα) expression using real-time PCR (qrt-PCR) with analytical capabilities to monitor patients, offering standard-curve reproducibility as well as intra- and inter-assay precision. Results Standard-curves were constructed by employing standardized Jurkat cell culture procedures, both for GRα and BCR (breakpoint cluster region), as a normalizing gene. We evaluated standard-curves using five different sets of cell culture passages, RNA extraction, reverse transcription, and qrt-PCR quantification. Intra-assay precision was evaluated using 12 replicates of each gene, for 2 patients, in a single experiment. Inter-assay precision was evaluated on 8 experiments, using duplicate tests of each gene for two patients. Standard-curves were reproducible, with CV (coefficient of variation) of less than 11%, and Pearson correlation coefficients above 0,990 for most comparisons. Intra-assay and inter-assay were 2% and 7%, respectively. Conclusion This is the first method for quantitation of GRα expression with technical characteristics that permit patient monitoring, in a fast, simple and robust way.