6 resultados para temporal comparison

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The few studies that have investigated judgments of time have suggested that the memory of duration is distorted more for emotional events than for neutral events, while in contrast there is abundant evidence that other aspects of memories of emotional events are more accurate. To reconcile this apparent discrepancy, we used a procedure in which the participants learned a standard duration over several trials under three emotional conditions: a threatening, a nonthreatening, and a neutral control condition. They were then tested either immediately or 24 h after learning. In this test phase, they had to indicate whether presented comparison durations were or were not the same as the previously learned standard duration. We found that durations were recalled better in the emotional than in the neutral condition, and that this occurred to a greater extent in the threatening than in the nonthreatening condition. Arousing emotions thus enhanced temporal memory, just as they enhance memory for other aspects of emotional events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An association between memory and executive dysfunction (ED) has been demonstrated in patients with mixed neurological disorders. We aimed to investigate the impact of ED in memory tasks of children with temporal lobe epilepsy (TLE). We evaluated 36 children with TLE and 28 controls with tests for memory, learning, attention, mental flexibility, and mental tracking. Data analysis was composed of comparison between patients and controls in memory and executive function; correlation between memory and executive function tests; and comparison between patients with mild and severe ED in memory tests. Children with TLE had worse performance in focused attention, immediate and delayed recall, phonological memory, mental tracking, planning, and abstraction. Planning, abstraction, and mental tracking were correlated with visual and verbal memory. Children with severe ED had worse performance in verbal and visual memory and learning tests. This study showed that ED was related to memory performance in children with TLE. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A procedure has been proposed by Ciotti and Bricaud (2006) to retrieve spectral absorption coefficients of phytoplankton and colored detrital matter (CDM) from satellite radiance measurements. This was also the first procedure to estimate a size factor for phytoplankton, based on the shape of the retrieved algal absorption spectrum, and the spectral slope of CDM absorption. Applying this method to the global ocean color data set acquired by SeaWiFS over twelve years (1998-2009), allowed for a comparison of the spatial variations of chlorophyll concentration ([Chl]), algal size factor (S-f), CDM absorption coefficient (a(cdm)) at 443 nm, and spectral slope of CDM absorption (S-cdm). As expected, correlations between the derived parameters were characterized by a large scatter at the global scale. We compared temporal variability of the spatially averaged parameters over the twelve-year period for three oceanic areas of biogeochemical importance: the Eastern Equatorial Pacific, the North Atlantic and the Mediterranean Sea. In all areas, both S-f and a(cdm)(443) showed large seasonal and interannual variations, generally correlated to those of algal biomass. The CDM maxima appeared in some occasions to last longer than those of [Chl]. The spectral slope of CDM absorption showed very large seasonal cycles consistent with photobleaching, challenging the assumption of a constant slope commonly used in bio-optical models. In the Equatorial Pacific, the seasonal cycles of [Chl], S-f, a(cdm)(443) and S-cdm, as well as the relationships between these parameters, were strongly affected by the 1997-98 El Ni o/La Ni a event.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Comparar do débito cardíaco (DC) e a fração de ejeção (FE) do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC). MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL) com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino) e a FE (masculina e feminina) foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05). CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC) não apresentaram diferença significativa em relação ao gênero.