3 resultados para tecnologie appropriate impianti off-grid energia elettrica
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Abstract Background To identify the most appropriate cut-off points of fasting glycemia for the screening of diabetes mellitus type 2 (DM2) with the comparison of the properties of capillary glycemia (CG) and venous blood plasma glycemia (PG) in a population of Japanese origin from the community of Mombuca, Guatapará - SP, Brazil. Methods This was a population-based descriptive cross-sectional study conducted on a sample of 131 individuals of both genders aged 20 years or more (66.8% of the target population). CG was measured with a glucometer in a blood sample obtained from the fingertip and PG was determined by an enzymatic method (hexokinase) in venous blood plasma, after a 10-14 hour fast in both cases. Data were analyzed by the receiver operating characteristic (ROC) curve in order to identify the best cut-off point for fasting glycemia (CG and PG) for the diagnosis of DM, using the 2-hour plasma glycemia > 200 mg/dl as gold - standard. Results The ROC curve revealed that the best cut-off point for the screening of DM was 110 mg/dl for CG and 105 mg/dl for PG, values that would optimize the relation between individuals with positive and false-positive results. The area under the ROC curve was 0.814 for CG (p < 0.01) and 0.836 for PG (p < 0.01). Conclusions The cut-off points of 105 mg/dl(5.8 mmol/l) for PG and of 110 mg/dl(6.1 mmol/l) for CG appear to be the most appropriate for the screening of DM2 in the population under study, with emphasis on the fact that the value recommended for CG is 5 mg/dl higher than that for PG, in contrast to WHO recommendations.
Resumo:
In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage supplies. This paper investigates the use of the induced voltage in the shield wires of an overhead 525 kV transmission line as a primary power source. Since phase current variations throughout the day affect the induced voltage in the overhead ground wire, a step-down dc-dc converter is used after rectification of the ac voltage to provide a regulated dc output voltage. The initial encouraging results obtained indicate that this form of power supply can be a feasible and cost-effective alternative for feeding small ancillary service loads. The simulation results are validated by field measurements as well as the installation of a 200 W voltage stabilization system prototype.
Resumo:
In recent decades, Oceanography has been using a variety of radionuclides as tracers to understand the ocean dynamic processes, handling and disposal of sediments of seabed. In this context, the determination of natural radionuclides distributions (238U, 232Th and 40K) has been carried out with sediments samples from the shelf and upper slope off Southeast Brazil using a gamma spectrometry technique. The samples were sliced into strata of 2 cm, dried, ground and properly packed to be analysed. The concentration of activities was performed in a hyperpure Ge detector with a resolution of 1,9 keV for the peak of 1332,3 keV of 60Co, model GEM50P by EGG&ORTEC. The study area is located between latitudes 28°40'S and 23°00'S and extends from Cabo Frio (RJ) to Cabo de Santa Marta Grande (SC). The activity concentrations varied from 0,6 to 52,8 BqKg-1 for 238U, from 1,6 to 50,9BqKg-1 for 232Th and from 65,4 to 873,3 BqKg-1 for 40K. From these results it is possible to establish a correlation between the depositional area dynamics and the samples size parameters